Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -103,6 +103,7 @@ 103 103 * Support Modbus protocol 104 104 * Support Interrupt uplink (Since hardware version v1.2) 105 105 106 + 106 106 == 1.4 Applications == 107 107 108 108 * Smart Buildings & Home Automation ... ... @@ -112,6 +112,7 @@ 112 112 * Smart Cities 113 113 * Smart Factory 114 114 116 + 115 115 == 1.5 Firmware Change log == 116 116 117 117 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -305,6 +305,8 @@ 305 305 ))) 306 306 ))) 307 307 310 + 311 + 308 308 === 3.3.2 Configure sensors === 309 309 310 310 ((( ... ... @@ -323,6 +323,8 @@ 323 323 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 324 324 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 325 325 330 + 331 + 326 326 === 3.3.3 Configure read commands for each sampling === 327 327 328 328 ((( ... ... @@ -1178,20 +1178,20 @@ 1178 1178 == 3.7 Buttons == 1179 1179 1180 1180 1181 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)1182 -|= (% style="width: 30px;" %)**Button**|=(% style="width:355px;" %)**Feature**1183 -| (% style="width:30px" %)**ACT**|(% style="width:355px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**1184 -| (% style="width:30px" %)**RST**|(% style="width:355px" %)Reboot RS4851185 -| (% style="width:30px" %)**PRO**|(% style="width:355px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]1187 +(% border="1" style="background-color:#f7faff; width:500px" %) 1188 +|=**Button**|=(% style="width: 1420px;" %)**Feature** 1189 +|**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 1190 +|**RST**|(% style="width:1420px" %)Reboot RS485 1191 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1186 1186 1187 1187 1194 + 1188 1188 == 3.8 LEDs == 1189 1189 1190 - 1191 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1197 +(% border="1" style="background-color:#f7faff; width:500px" %) 1192 1192 |=**LEDs**|=**Feature** 1193 1193 |**PWR**|Always on if there is power 1194 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink 1200 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1195 1195 1196 1196 1197 1197 ... ... @@ -1204,26 +1204,19 @@ 1204 1204 1205 1205 == 5.1 Access AT Command == 1206 1206 1207 -((( 1208 1208 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1209 -))) 1210 1210 1211 1211 [[image:1654162355560-817.png]] 1212 1212 1213 1213 1214 -((( 1215 1215 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1216 -))) 1217 1217 1218 1218 [[image:1654162368066-342.png]] 1219 1219 1220 1220 1221 -((( 1222 1222 More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1223 -))) 1224 1224 1225 1225 1226 - 1227 1227 == 5.2 Common AT Command Sequence == 1228 1228 1229 1229 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === ... ... @@ -1297,23 +1297,13 @@ 1297 1297 1298 1298 == 6.1 How to upgrade the image? == 1299 1299 1300 -((( 1301 1301 The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to: 1302 -))) 1303 1303 1304 -* ((( 1305 -Support new features 1306 -))) 1307 -* ((( 1308 -For bug fix 1309 -))) 1310 -* ((( 1311 -Change LoRaWAN bands. 1312 -))) 1301 +* Support new features 1302 +* For bug fix 1303 +* Change LoRaWAN bands. 1313 1313 1314 -((( 1315 1315 Below shows the hardware connection for how to upload an image to RS485-LN: 1316 -))) 1317 1317 1318 1318 [[image:1654162535040-878.png]] 1319 1319 ... ... @@ -1324,10 +1324,8 @@ 1324 1324 **Step3: **Open flashloader; choose the correct COM port to update. 1325 1325 1326 1326 ((( 1327 -((( 1328 1328 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 1329 1329 ))) 1330 -))) 1331 1331 1332 1332 1333 1333 [[image:image-20220602175818-12.png]] ... ... @@ -1390,6 +1390,7 @@ 1390 1390 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1391 1391 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1392 1392 1380 + 1393 1393 = 9.Packing Info = 1394 1394 1395 1395 ... ... @@ -1406,6 +1406,7 @@ 1406 1406 * Package Size / pcs : 14.5 x 8 x 5 cm 1407 1407 * Weight / pcs : 170g 1408 1408 1397 + 1409 1409 = 10. FCC Caution for RS485LN-US915 = 1410 1410 1411 1411 (((