From version < 58.34 >
edited by Xiaoling
on 2022/06/06 11:48
To version < 58.47 >
edited by Xiaoling
on 2022/06/06 13:44
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -233,11 +233,15 @@
233 233  
234 234  (((
235 235  (((
236 +(((
236 236  There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
237 237  )))
239 +)))
238 238  
239 239  (((
242 +(((
240 240  (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1
244 +)))
241 241  
242 242  
243 243  )))
... ... @@ -305,6 +305,7 @@
305 305  )))
306 306  )))
307 307  
312 +
308 308  === 3.3.2 Configure sensors ===
309 309  
310 310  (((
... ... @@ -323,6 +323,7 @@
323 323  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
324 324  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
325 325  
331 +
326 326  === 3.3.3 Configure read commands for each sampling ===
327 327  
328 328  (((
... ... @@ -1100,29 +1100,29 @@
1100 1100  )))
1101 1101  
1102 1102  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
1103 -|=(% style="width: 161px;" %)(((
1104 -**Command example:**
1105 -)))|=(% style="width: 337px;" %)(((
1109 +|=(% style="width: 100px;" %)(((
1110 +**Command example**
1111 +)))|=(% style="width: 400px;" %)(((
1106 1106  **Function**
1107 1107  )))
1108 -|(% style="width:161px" %)(((
1114 +|(% style="width:100px" %)(((
1109 1109  AT+RXMODE=1,10
1110 -)))|(% style="width:337px" %)(((
1116 +)))|(% style="width:400px" %)(((
1111 1111  Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
1112 1112  )))
1113 -|(% style="width:161px" %)(((
1119 +|(% style="width:100px" %)(((
1114 1114  AT+RXMODE=2,500
1115 -)))|(% style="width:337px" %)(((
1121 +)))|(% style="width:400px" %)(((
1116 1116  Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
1117 1117  )))
1118 -|(% style="width:161px" %)(((
1124 +|(% style="width:100px" %)(((
1119 1119  AT+RXMODE=0,0
1120 -)))|(% style="width:337px" %)(((
1126 +)))|(% style="width:400px" %)(((
1121 1121  Disable listening mode. This is the default settings.
1122 1122  )))
1123 -|(% style="width:161px" %)(((
1129 +|(% style="width:100px" %)(((
1124 1124  
1125 -)))|(% style="width:337px" %)(((
1131 +)))|(% style="width:400px" %)(((
1126 1126  A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 | cc)
1127 1127  )))
1128 1128  
... ... @@ -1178,21 +1178,21 @@
1178 1178  == 3.7 Buttons ==
1179 1179  
1180 1180  
1181 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1182 -|=(% style="width: 30px;" %)**Button**|=(% style="width: 355px;" %)**Feature**
1183 -|(% style="width:30px" %)**ACT**|(% style="width:355px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1184 -|(% style="width:30px" %)**RST**|(% style="width:355px" %)Reboot RS485
1185 -|(% style="width:30px" %)**PRO**|(% style="width:355px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1187 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:400px" %)
1188 +|=(% style="width: 50px;" %)**Button**|=(% style="width: 350px;" %)**Feature**
1189 +|(% style="width:50px" %)**ACT**|(% style="width:350px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1190 +|(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485
1191 +|(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1186 1186  
1187 1187  
1188 1188  == 3.8 LEDs ==
1189 1189  
1196 +
1190 1190  (% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1191 -|=(% style="width: 30px;" %)**LEDs**|=(% style="width: 400px;" %)**Feature**
1192 -|(% style="width:30px" %)**PWR**|=(% style="width: 400px;" %)Always on if there is power
1193 -|(% style="width:30px" %)**SYS**|=(% style="width: 400px;" %)After device is powered on, the SYS will (% style="color:green" %)fast blink in GREEN (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)on GREEN for 5 seconds(%%). SYS will (% style="color:green" %)blink Blue(%%) on every upload and (% style="color:green" %)blink Green(%%) once receive a downlink message.
1198 +|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature**
1199 +|**PWR**|Always on if there is power
1200 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1194 1194  
1195 -
1196 1196  = 4. Case Study =
1197 1197  
1198 1198  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1322,8 +1322,10 @@
1322 1322  **Step3: **Open flashloader; choose the correct COM port to update.
1323 1323  
1324 1324  (((
1331 +(((
1325 1325  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1326 1326  )))
1334 +)))
1327 1327  
1328 1328  
1329 1329  [[image:image-20220602175818-12.png]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved