From version < 58.31 >
edited by Xiaoling
on 2022/06/06 11:44
To version < 58.44 >
edited by Xiaoling
on 2022/06/06 13:39
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -92,6 +92,7 @@
92 92  * Automatic RF Sense and CAD with ultra-fast AFC.
93 93  * Packet engine up to 256 bytes with CRC
94 94  
95 +
95 95  == 1.3 Features ==
96 96  
97 97  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -103,6 +103,7 @@
103 103  * Support Modbus protocol
104 104  * Support Interrupt uplink (Since hardware version v1.2)
105 105  
107 +
106 106  == 1.4 Applications ==
107 107  
108 108  * Smart Buildings & Home Automation
... ... @@ -112,6 +112,7 @@
112 112  * Smart Cities
113 113  * Smart Factory
114 114  
117 +
115 115  == 1.5 Firmware Change log ==
116 116  
117 117  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -233,11 +233,15 @@
233 233  
234 234  (((
235 235  (((
239 +(((
236 236  There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
237 237  )))
242 +)))
238 238  
239 239  (((
245 +(((
240 240  (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1
247 +)))
241 241  
242 242  
243 243  )))
... ... @@ -305,6 +305,8 @@
305 305  )))
306 306  )))
307 307  
315 +
316 +
308 308  === 3.3.2 Configure sensors ===
309 309  
310 310  (((
... ... @@ -323,6 +323,8 @@
323 323  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
324 324  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
325 325  
335 +
336 +
326 326  === 3.3.3 Configure read commands for each sampling ===
327 327  
328 328  (((
... ... @@ -1100,29 +1100,29 @@
1100 1100  )))
1101 1101  
1102 1102  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
1103 -|=(% style="width: 161px;" %)(((
1104 -**Command example:**
1105 -)))|=(% style="width: 337px;" %)(((
1114 +|=(% style="width: 100px;" %)(((
1115 +**Command example**
1116 +)))|=(% style="width: 400px;" %)(((
1106 1106  **Function**
1107 1107  )))
1108 -|(% style="width:161px" %)(((
1119 +|(% style="width:100px" %)(((
1109 1109  AT+RXMODE=1,10
1110 -)))|(% style="width:337px" %)(((
1121 +)))|(% style="width:400px" %)(((
1111 1111  Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
1112 1112  )))
1113 -|(% style="width:161px" %)(((
1124 +|(% style="width:100px" %)(((
1114 1114  AT+RXMODE=2,500
1115 -)))|(% style="width:337px" %)(((
1126 +)))|(% style="width:400px" %)(((
1116 1116  Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
1117 1117  )))
1118 -|(% style="width:161px" %)(((
1129 +|(% style="width:100px" %)(((
1119 1119  AT+RXMODE=0,0
1120 -)))|(% style="width:337px" %)(((
1131 +)))|(% style="width:400px" %)(((
1121 1121  Disable listening mode. This is the default settings.
1122 1122  )))
1123 -|(% style="width:161px" %)(((
1134 +|(% style="width:100px" %)(((
1124 1124  
1125 -)))|(% style="width:337px" %)(((
1136 +)))|(% style="width:400px" %)(((
1126 1126  A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 | cc)
1127 1127  )))
1128 1128  
... ... @@ -1178,23 +1178,20 @@
1178 1178  == 3.7 Buttons ==
1179 1179  
1180 1180  
1181 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1182 -|=(% style="width: 30px;" %)**Button**|=(% style="width: 355px;" %)**Feature**
1183 -|=(% style="width: 30px;" %)**ACT**|(% style="width:355px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1184 -|=(% style="width: 30px;" %)**RST**|(% style="width:355px" %)Reboot RS485
1185 -|=(% style="width: 30px;" %)**PRO**|(% style="width:355px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1192 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:400px" %)
1193 +|=(% style="width: 50px;" %)**Button**|=(% style="width: 350px;" %)**Feature**
1194 +|(% style="width:50px" %)**ACT**|(% style="width:350px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1195 +|(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485
1196 +|(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1186 1186  
1187 -
1188 -
1189 1189  == 3.8 LEDs ==
1190 1190  
1191 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)
1192 -|=(% style="width: 30px;" %)**LEDs**|=(% style="width: 400px;" %)**Feature**
1193 -|(% style="width:30px" %)**PWR**|=(% style="width: 400px;" %)Always on if there is power
1194 -|(% style="width:30px" %)**SYS**|=(% style="width: 400px;" %)After device is powered on, the SYS will (% style="color:green" %)fast blink in GREEN (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)on GREEN for 5 seconds(%%). SYS will (% style="color:green" %)blink Blue(%%) on every upload and (% style="color:green" %)blink Green(%%) once receive a downlink message.
1195 1195  
1201 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1202 +|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature**
1203 +|**PWR**|Always on if there is power
1204 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1196 1196  
1197 -
1198 1198  = 4. Case Study =
1199 1199  
1200 1200  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1297,13 +1297,23 @@
1297 1297  
1298 1298  == 6.1 How to upgrade the image? ==
1299 1299  
1308 +(((
1300 1300  The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to:
1310 +)))
1301 1301  
1302 -* Support new features
1303 -* For bug fix
1304 -* Change LoRaWAN bands.
1312 +* (((
1313 +Support new features
1314 +)))
1315 +* (((
1316 +For bug fix
1317 +)))
1318 +* (((
1319 +Change LoRaWAN bands.
1320 +)))
1305 1305  
1322 +(((
1306 1306  Below shows the hardware connection for how to upload an image to RS485-LN:
1324 +)))
1307 1307  
1308 1308  [[image:1654162535040-878.png]]
1309 1309  
... ... @@ -1314,8 +1314,10 @@
1314 1314  **Step3: **Open flashloader; choose the correct COM port to update.
1315 1315  
1316 1316  (((
1335 +(((
1317 1317  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1318 1318  )))
1338 +)))
1319 1319  
1320 1320  
1321 1321  [[image:image-20220602175818-12.png]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0