Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -550,58 +550,121 @@ 550 550 551 551 ==== **RS485 Debug Command** ==== 552 552 553 +((( 553 553 This command is used to configure the RS485 devices; they won’t be used during sampling. 555 +))) 554 554 555 -* **AT Command** 557 +* ((( 558 +**AT Command** 559 +))) 556 556 557 557 (% class="box infomessage" %) 558 558 ((( 563 +((( 559 559 **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 560 560 ))) 566 +))) 561 561 568 +((( 562 562 m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 570 +))) 563 563 564 -* **Downlink Payload** 572 +* ((( 573 +**Downlink Payload** 574 +))) 565 565 576 +((( 566 566 Format: A8 MM NN XX XX XX XX YY 578 +))) 567 567 580 +((( 568 568 Where: 582 +))) 569 569 570 -* MM: 1: add CRC-16/MODBUS ; 0: no CRC 571 -* NN: The length of RS485 command 572 -* XX XX XX XX: RS485 command total NN bytes 573 -* YY: How many bytes will be uplink from the return of this RS485 command, 574 -** if YY=0, RS485-LN will execute the downlink command without uplink; 575 -** if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200 576 -** if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200. 584 +* ((( 585 +MM: 1: add CRC-16/MODBUS ; 0: no CRC 586 +))) 587 +* ((( 588 +NN: The length of RS485 command 589 +))) 590 +* ((( 591 +XX XX XX XX: RS485 command total NN bytes 592 +))) 593 +* ((( 594 +((( 595 +YY: How many bytes will be uplink from the return of this RS485 command, 596 +))) 577 577 598 +* ((( 599 +if YY=0, RS485-LN will execute the downlink command without uplink; 600 +))) 601 +* ((( 602 +if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200 603 +))) 604 +* ((( 605 +if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200. 606 +))) 607 +))) 608 + 609 +((( 578 578 **Example 1** ~-~-> Configure without ask for uplink (YY=0) 611 +))) 579 579 613 +((( 580 580 To connect a Modbus Alarm with below commands. 615 +))) 581 581 582 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 617 +* ((( 618 +The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 619 +))) 583 583 584 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 621 +* ((( 622 +The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 623 +))) 585 585 625 +((( 586 586 So if user want to use downlink command to control to RS485 Alarm, he can use: 627 +))) 587 587 629 +((( 588 588 (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 631 +))) 589 589 633 +((( 590 590 (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 635 +))) 591 591 637 +((( 592 592 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 639 +))) 593 593 641 +((( 642 + 643 +))) 594 594 645 +((( 595 595 **Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 647 +))) 596 596 649 +((( 597 597 User in IoT server send a downlink command: (% style="color:#4f81bd" %)**A8 01 06 0A 08 00 04 00 01 YY** 651 +))) 598 598 653 +((( 654 + 655 +))) 599 599 657 +((( 600 600 RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: 659 +))) 601 601 661 +((( 602 602 **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 663 +))) 603 603 665 +((( 604 604 [[image:1654159460680-153.png]] 667 +))) 605 605 606 606 607 607