From version < 58.3 >
edited by Xiaoling
on 2022/06/06 11:14
To version < 58.30 >
edited by Xiaoling
on 2022/06/06 11:42
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,5 @@
1 1  (% style="text-align:center" %)
2 -[[image:1653266934636-343.png||height="385" width="385"]]
2 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653266934636-343.png?width=385&height=385&rev=1.1||alt="1653266934636-343.png" height="385" width="385"]]
3 3  
4 4  
5 5  
... ... @@ -10,7 +10,59 @@
10 10  
11 11  **Table of Contents:**
12 12  
13 -{{toc/}}
13 +* [[1.Introduction>>path:#H1.Introduction]]
14 +** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>path:#H1.1A0WhatisRS485-LNRS485toLoRaWANConverter]]
15 +** [[1.2 Specifications>>path:#H1.2A0Specifications]]
16 +** [[1.3 Features>>path:#H1.3Features]]
17 +** [[1.4 Applications>>path:#H1.4A0Applications]]
18 +** [[1.5 Firmware Change log>>path:#H1.5A0FirmwareChangelog]]
19 +** [[1.6 Hardware Change log>>path:#H1.6HardwareChangelog]]
20 +* [[2. Power ON Device>>path:#H2.PowerONDevice]]
21 +* [[3. Operation Mode>>path:#H3.A0OperationMode]]
22 +** [[3.1 How it works?>>path:#H3.1Howitworks3F]]
23 +** [[3.2 Example to join LoRaWAN network>>path:#H3.2ExampletojoinLoRaWANnetwork]]
24 +** [[3.3 Configure Commands to read data>>path:#H3.3ConfigureCommandstoreaddata]]
25 +*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>path:#H3.3.1onfigureUARTsettingsforRS485orTTLcommunication]]
26 +*** [[3.3.2 Configure sensors>>path:#H3.3.2Configuresensors]]
27 +*** [[3.3.3 Configure read commands for each sampling>>path:#H3.3.3Configurereadcommandsforeachsampling]]
28 +*** [[3.3.4 Compose the uplink payload>>path:#H3.3.4Composetheuplinkpayload]]
29 +*** [[3.3.5 Uplink on demand>>path:#H3.3.5Uplinkondemand]]
30 +*** [[3.3.6 Uplink on Interrupt>>path:#H3.3.6UplinkonInterrupt]]
31 +** [[3.4 Uplink Payload>>path:#H3.4UplinkPayload]]
32 +** [[3.5 Configure RS485-BL via AT or Downlink>>path:#H3.5ConfigureRS485-BLviaATorDownlink]]
33 +*** [[3.5.1 Common Commands>>path:#H3.5.1CommonCommands]]
34 +*** [[3.5.2 Sensor related commands>>path:#H3.5.2Sensorrelatedcommands]]
35 +*** [[3.5.3 Sensor related commands>>path:#H3.5.3A0Sensorrelatedcommands]]
36 +**** [[RS485 Debug Command>>path:#HRS485DebugCommand]]
37 +**** [[Set Payload version>>path:#HSetPayloadversion]]
38 +**** [[Set RS485 Sampling Commands>>path:#HSetRS485SamplingCommands]]
39 +**** [[Fast command to handle MODBUS device>>path:#HFastcommandtohandleMODBUSdevice]]
40 +**** [[RS485 command timeout>>path:#HRS485commandtimeout]]
41 +**** [[Uplink payload mode>>path:#HUplinkpayloadmode]]
42 +**** [[Manually trigger an Uplink>>path:#HManuallytriggeranUplink]]
43 +**** [[Clear RS485 Command>>path:#HClearRS485Command]]
44 +**** [[Set Serial Communication Parameters>>path:#HSetSerialCommunicationParameters]]
45 +** [[3.6 Listening mode for RS485 network>>path:#H3.6A0ListeningmodeforRS485network]]
46 +** [[3.7 Buttons>>path:#H3.7Buttons]]
47 +** [[3.8 LEDs>>path:#H3.8LEDs]]
48 +* [[4. Case Study>>path:#H4.CaseStudy]]
49 +* [[5. Use AT Command>>path:#H5.UseATCommand]]
50 +** [[5.1 Access AT Command>>path:#H5.1AccessATCommand]]
51 +** [[5.2 Common AT Command Sequence>>path:#H5.2CommonATCommandSequence]]
52 +*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>path:#H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829]]
53 +*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>path:#H5.5.2Single-channelABPmode28UsewithLG012FLG0229]]
54 +* [[6. FAQ>>path:#H6.FAQ]]
55 +** [[6.1 How to upgrade the image?>>path:#H6.1Howtoupgradetheimage3F]]
56 +** [[6.2 How to change the LoRa Frequency Bands/Region?>>path:#H6.2HowtochangetheLoRaFrequencyBands2FRegion3F]]
57 +** [[6.3 How many RS485-Slave can RS485-BL connects?>>path:#H6.3HowmanyRS485-SlavecanRS485-BLconnects3F]]
58 +** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>path:#H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F]]
59 +* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
60 +** [[7.1 Downlink doesn’t work, how to solve it?>>path:#H7.1Downlinkdoesn2019twork2Chowtosolveit3F]]
61 +** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>path:#H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F]]
62 +* [[8. Order Info>>path:#H8.OrderInfo]]
63 +* [[9.Packing Info>>path:#H9.PackingInfo]]
64 +* [[10. FCC Caution for RS485LN-US915>>path:#H10.FCCCautionforRS485LN-US915]]
65 +* [[11. Support>>path:#H11.Support]]
14 14  
15 15  
16 16  
... ... @@ -52,7 +52,7 @@
52 52  )))
53 53  )))
54 54  
55 -[[image:1653267211009-519.png||height="419" width="724"]]
107 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653267211009-519.png?width=724&height=419&rev=1.1||alt="1653267211009-519.png" height="419" width="724"]]
56 56  
57 57  
58 58  == 1.2 Specifications ==
... ... @@ -103,7 +103,6 @@
103 103  * Support Modbus protocol
104 104  * Support Interrupt uplink (Since hardware version v1.2)
105 105  
106 -
107 107  == 1.4 Applications ==
108 108  
109 109  * Smart Buildings & Home Automation
... ... @@ -113,7 +113,6 @@
113 113  * Smart Cities
114 114  * Smart Factory
115 115  
116 -
117 117  == 1.5 Firmware Change log ==
118 118  
119 119  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -147,7 +147,7 @@
147 147  Once there is power, the RS485-LN will be on.
148 148  )))
149 149  
150 -[[image:1653268091319-405.png]]
200 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268091319-405.png?rev=1.1||alt="1653268091319-405.png"]]
151 151  
152 152  
153 153  )))
... ... @@ -168,7 +168,7 @@
168 168  
169 169  Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
170 170  
171 -[[image:1653268155545-638.png||height="334" width="724"]]
221 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268155545-638.png?width=724&height=334&rev=1.1||alt="1653268155545-638.png" height="334" width="724"]]
172 172  
173 173  
174 174  (((
... ... @@ -180,10 +180,10 @@
180 180  485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively.
181 181  )))
182 182  
183 -[[image:1653268227651-549.png||height="592" width="720"]]
233 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268227651-549.png?width=720&height=592&rev=1.1||alt="1653268227651-549.png" height="592" width="720"]]
184 184  
185 185  (((
186 -The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:
236 +The LG308 is already set to connect to (% class="wikiinternallink" %)[[TTN V3 network >>url:https://www.thethingsnetwork.org/]](%%). So what we need to now is only configure the TTN V3:
187 187  )))
188 188  
189 189  (((
... ... @@ -195,7 +195,7 @@
195 195  )))
196 196  )))
197 197  
198 -[[image:1652953462722-299.png]]
248 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953462722-299.png?rev=1.1||alt="1652953462722-299.png"]]
199 199  
200 200  (((
201 201  (((
... ... @@ -207,21 +207,21 @@
207 207  )))
208 208  )))
209 209  
210 -[[image:image-20220519174512-1.png]]
260 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-1.png?rev=1.1||alt="image-20220519174512-1.png"]]
211 211  
212 -[[image:image-20220519174512-2.png||height="323" width="720"]]
262 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-2.png?width=720&height=323&rev=1.1||alt="image-20220519174512-2.png" height="323" width="720"]]
213 213  
214 -[[image:image-20220519174512-3.png||height="556" width="724"]]
264 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-3.png?width=724&height=556&rev=1.1||alt="image-20220519174512-3.png" height="556" width="724"]]
215 215  
216 -[[image:image-20220519174512-4.png]]
266 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-4.png?rev=1.1||alt="image-20220519174512-4.png"]]
217 217  
218 218  You can also choose to create the device manually.
219 219  
220 -[[image:1652953542269-423.png||height="710" width="723"]]
270 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953542269-423.png?width=723&height=710&rev=1.1||alt="1652953542269-423.png" height="710" width="723"]]
221 221  
222 222  Add APP KEY and DEV EUI
223 223  
224 -[[image:1652953553383-907.png||height="514" width="724"]]
274 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953553383-907.png?width=724&height=514&rev=1.1||alt="1652953553383-907.png" height="514" width="724"]]
225 225  
226 226  
227 227  (((
... ... @@ -228,7 +228,7 @@
228 228  **Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
229 229  )))
230 230  
231 -[[image:1652953568895-172.png||height="232" width="724"]]
281 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953568895-172.png?width=724&height=232&rev=1.1||alt="1652953568895-172.png" height="232" width="724"]]
232 232  
233 233  
234 234  == 3.3 Configure Commands to read data ==
... ... @@ -235,7 +235,7 @@
235 235  
236 236  (((
237 237  (((
238 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
288 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
239 239  )))
240 240  
241 241  (((
... ... @@ -307,8 +307,6 @@
307 307  )))
308 308  )))
309 309  
310 -
311 -
312 312  === 3.3.2 Configure sensors ===
313 313  
314 314  (((
... ... @@ -327,8 +327,6 @@
327 327  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
328 328  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
329 329  
330 -
331 -
332 332  === 3.3.3 Configure read commands for each sampling ===
333 333  
334 334  (((
... ... @@ -387,17 +387,17 @@
387 387  
388 388  * Grab bytes:
389 389  
390 -[[image:image-20220602153621-1.png]]
436 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-1.png?rev=1.1||alt="image-20220602153621-1.png"]]
391 391  
392 392  
393 393  * Grab a section.
394 394  
395 -[[image:image-20220602153621-2.png]]
441 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-2.png?rev=1.1||alt="image-20220602153621-2.png"]]
396 396  
397 397  
398 398  * Grab different sections.
399 399  
400 -[[image:image-20220602153621-3.png]]
446 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-3.png?rev=1.1||alt="image-20220602153621-3.png"]]
401 401  
402 402  
403 403  )))
... ... @@ -432,7 +432,7 @@
432 432  Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
433 433  )))
434 434  
435 -[[image:1653269759169-150.png||height="513" width="716"]]
481 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653269759169-150.png?width=716&height=513&rev=1.1||alt="1653269759169-150.png" height="513" width="716"]]
436 436  
437 437  
438 438  (% style="color:#037691" %)**Examples: AT+DATAUP=1**
... ... @@ -450,7 +450,7 @@
450 450  1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
451 451  1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes
452 452  
453 -[[image:image-20220602155039-4.png]]
499 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602155039-4.png?rev=1.1||alt="image-20220602155039-4.png"]]
454 454  
455 455  
456 456  So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA
... ... @@ -475,7 +475,7 @@
475 475  
476 476  Below are the uplink payloads:
477 477  
478 -[[image:1654157178836-407.png]]
524 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157178836-407.png?rev=1.1||alt="1654157178836-407.png"]]
479 479  
480 480  
481 481  === 3.3.5 Uplink on demand ===
... ... @@ -494,7 +494,7 @@
494 494  
495 495  RS485-LN support external Interrupt uplink since hardware v1.2 release.
496 496  
497 -[[image:1654157342174-798.png]]
543 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157342174-798.png?rev=1.1||alt="1654157342174-798.png"]]
498 498  
499 499  Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet.
500 500  
... ... @@ -502,7 +502,7 @@
502 502  == 3.4 Uplink Payload ==
503 503  
504 504  
505 -[[image:image-20220606110929-1.png]]
551 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220606110929-1.png?rev=1.1||alt="image-20220606110929-1.png"]]
506 506  
507 507  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
508 508  
... ... @@ -518,7 +518,7 @@
518 518  )))
519 519  
520 520  * (((
521 -(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
567 +(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
522 522  )))
523 523  
524 524  * (((
... ... @@ -532,7 +532,7 @@
532 532  
533 533  === 3.5.1 Common Commands ===
534 534  
535 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
581 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
536 536  
537 537  
538 538  === 3.5.2 Sensor related commands ===
... ... @@ -539,7 +539,7 @@
539 539  
540 540  Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server.
541 541  
542 -[[image:image-20220602163333-5.png||height="263" width="1160"]]
588 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602163333-5.png?width=1160&height=263&rev=1.1||alt="image-20220602163333-5.png" height="263" width="1160"]]
543 543  
544 544  The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable)
545 545  
... ... @@ -548,347 +548,660 @@
548 548  
549 549  
550 550  
597 +
551 551  ==== **RS485 Debug Command** ====
552 552  
600 +(((
553 553  This command is used to configure the RS485 devices; they won’t be used during sampling.
602 +)))
554 554  
555 -* **AT Command**
604 +* (((
605 +**AT Command**
606 +)))
556 556  
557 557  (% class="box infomessage" %)
558 558  (((
610 +(((
559 559  **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
560 560  )))
613 +)))
561 561  
615 +(((
562 562  m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
617 +)))
563 563  
564 -* **Downlink Payload**
619 +* (((
620 +**Downlink Payload**
621 +)))
565 565  
623 +(((
566 566  Format: A8 MM NN XX XX XX XX YY
625 +)))
567 567  
627 +(((
568 568  Where:
629 +)))
569 569  
570 -* MM: 1: add CRC-16/MODBUS ; 0: no CRC
571 -* NN: The length of RS485 command
572 -* XX XX XX XX: RS485 command total NN bytes
573 -* YY: How many bytes will be uplink from the return of this RS485 command,
574 -** if YY=0, RS485-LN will execute the downlink command without uplink;
575 -** if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200
576 -** if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200.
631 +* (((
632 +MM: 1: add CRC-16/MODBUS ; 0: no CRC
633 +)))
634 +* (((
635 +NN: The length of RS485 command
636 +)))
637 +* (((
638 +XX XX XX XX: RS485 command total NN bytes
639 +)))
640 +* (((
641 +(((
642 +YY: How many bytes will be uplink from the return of this RS485 command,
643 +)))
577 577  
645 +* (((
646 +if YY=0, RS485-LN will execute the downlink command without uplink;
647 +)))
648 +* (((
649 +if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200
650 +)))
651 +* (((
652 +if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200.
653 +)))
654 +)))
655 +
656 +(((
578 578  **Example 1** ~-~-> Configure without ask for uplink (YY=0)
658 +)))
579 579  
660 +(((
580 580  To connect a Modbus Alarm with below commands.
662 +)))
581 581  
582 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
664 +* (((
665 +The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
666 +)))
583 583  
584 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
668 +* (((
669 +The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
670 +)))
585 585  
672 +(((
586 586  So if user want to use downlink command to control to RS485 Alarm, he can use:
674 +)))
587 587  
676 +(((
588 588  (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm
678 +)))
589 589  
680 +(((
590 590  (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm
682 +)))
591 591  
684 +(((
592 592  A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
686 +)))
593 593  
688 +(((
689 +
690 +)))
594 594  
692 +(((
595 595  **Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
694 +)))
596 596  
696 +(((
597 597  User in IoT server send a downlink command: (% style="color:#4f81bd" %)**A8 01 06 0A 08 00 04 00 01 YY**
698 +)))
598 598  
700 +(((
701 +
702 +)))
599 599  
704 +(((
600 600  RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:
706 +)))
601 601  
708 +(((
602 602   **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
710 +)))
603 603  
604 - [[image:1654159460680-153.png]]
712 +(((
713 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654159460680-153.png?rev=1.1||alt="1654159460680-153.png"]]
714 +)))
605 605  
606 606  
607 607  
718 +
608 608  ==== **Set Payload version** ====
609 609  
721 +(((
610 610  This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
723 +)))
611 611  
612 -* **AT Command:**
725 +* (((
726 +**AT Command:**
727 +)))
613 613  
614 614  (% class="box infomessage" %)
615 615  (((
731 +(((
616 616  **AT+PAYVER: Set PAYVER field = 1**
617 617  )))
734 +)))
618 618  
619 -* **Downlink Payload:**
736 +* (((
737 +**Downlink Payload:**
738 +)))
620 620  
740 +(((
621 621  **0xAE 01**  ~-~-> Set PAYVER field =  0x01
742 +)))
622 622  
744 +(((
623 623  **0xAE 0F**   ~-~-> Set PAYVER field =  0x0F
746 +)))
624 624  
625 625  
626 626  
750 +
627 627  ==== **Set RS485 Sampling Commands** ====
628 628  
753 +(((
629 629  AT+COMMANDx or AT+DATACUTx
755 +)))
630 630  
631 -These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
757 +(((
758 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#H3.3.3Configurereadcommandsforeachsampling]].
759 +)))
632 632  
761 +(((
762 +
763 +)))
633 633  
634 -* **AT Command:**
765 +* (((
766 +**AT Command:**
767 +)))
635 635  
636 636  (% class="box infomessage" %)
637 637  (((
771 +(((
638 638  **AT+COMMANDx: Configure RS485 read command to sensor.**
639 639  )))
774 +)))
640 640  
641 641  (% class="box infomessage" %)
642 642  (((
778 +(((
643 643  **AT+DATACUTx: Configure how to handle return from RS485 devices.**
644 644  )))
781 +)))
645 645  
783 +(((
784 +
785 +)))
646 646  
647 -* **Downlink Payload:**
787 +* (((
788 +**Downlink Payload:**
789 +)))
648 648  
791 +(((
649 649  **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
793 +)))
650 650  
795 +(((
651 651  (% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
797 +)))
652 652  
799 +(((
653 653  Format: AF MM NN LL XX XX XX XX YY
801 +)))
654 654  
803 +(((
655 655  Where:
805 +)))
656 656  
657 -* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
658 -* NN:  0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
659 -* LL:  The length of AT+COMMAND or AT+DATACUT command
660 -* XX XX XX XX: AT+COMMAND or AT+DATACUT command
661 -* YY:  If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.
807 +* (((
808 +MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
809 +)))
810 +* (((
811 +NN:  0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
812 +)))
813 +* (((
814 +LL:  The length of AT+COMMAND or AT+DATACUT command
815 +)))
816 +* (((
817 +XX XX XX XX: AT+COMMAND or AT+DATACUT command
818 +)))
819 +* (((
820 +YY:  If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.
821 +)))
662 662  
823 +(((
663 663  **Example:**
825 +)))
664 664  
827 +(((
665 665  (% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1
829 +)))
666 666  
831 +(((
667 667  (% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10**
833 +)))
668 668  
835 +(((
669 669  (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10**
837 +)))
670 670  
671 671  
672 672  
841 +
673 673  ==== **Fast command to handle MODBUS device** ====
674 674  
844 +(((
675 675  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
846 +)))
676 676  
848 +(((
677 677  This command is valid since v1.3 firmware version
850 +)))
678 678  
852 +(((
679 679  AT+MBFUN can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore.
854 +)))
680 680  
856 +(((
857 +
858 +)))
681 681  
860 +(((
682 682  **Example:**
862 +)))
683 683  
684 -* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
685 -* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
686 -* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
864 +* (((
865 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
866 +)))
867 +* (((
868 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
869 +)))
870 +* (((
871 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
872 +)))
687 687  
688 -[[image:image-20220602165351-6.png]]
874 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-6.png?rev=1.1||alt="image-20220602165351-6.png"]]
689 689  
690 -[[image:image-20220602165351-7.png]]
876 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-7.png?rev=1.1||alt="image-20220602165351-7.png"]]
691 691  
692 692  
693 693  
880 +
694 694  ==== **RS485 command timeout** ====
695 695  
883 +(((
696 696  Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
885 +)))
697 697  
887 +(((
698 698  Default value: 0, range:  0 ~~ 65 seconds
889 +)))
699 699  
700 -* **AT Command:**
891 +* (((
892 +**AT Command:**
893 +)))
701 701  
702 702  (% class="box infomessage" %)
703 703  (((
897 +(((
704 704  **AT+CMDDLaa=hex(bb cc)*1000**
705 705  )))
900 +)))
706 706  
902 +(((
707 707  **Example:**
904 +)))
708 708  
906 +(((
709 709  **AT+CMDDL1=1000** to send the open time to 1000ms
908 +)))
710 710  
910 +(((
911 +
912 +)))
711 711  
712 -* **Downlink Payload:**
914 +* (((
915 +**Downlink Payload:**
916 +)))
713 713  
918 +(((
714 714  **0x AA aa bb cc**
920 +)))
715 715  
922 +(((
716 716  Same as: AT+CMDDLaa=hex(bb cc)*1000
924 +)))
717 717  
926 +(((
718 718   **Example:**
928 +)))
719 719  
930 +(((
720 720   0xAA 01 00 01  ~-~-> Same as **AT+CMDDL1=1000 ms**
932 +)))
721 721  
722 722  
723 723  
936 +
724 724  ==== **Uplink payload mode** ====
725 725  
939 +(((
726 726  Define to use one uplink or multiple uplinks for the sampling.
941 +)))
727 727  
728 -The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
943 +(((
944 +The use of this command please see: [[Compose Uplink payload>>path:#H3.3.4Composetheuplinkpayload]]
945 +)))
729 729  
730 -* **AT Command:**
947 +* (((
948 +**AT Command:**
949 +)))
731 731  
732 732  (% class="box infomessage" %)
733 733  (((
953 +(((
734 734  **AT+DATAUP=0**
735 735  )))
956 +)))
736 736  
737 737  (% class="box infomessage" %)
738 738  (((
960 +(((
739 739  **AT+DATAUP=1**
740 740  )))
963 +)))
741 741  
965 +(((
966 +
967 +)))
742 742  
743 -* **Downlink Payload:**
969 +* (((
970 +**Downlink Payload:**
971 +)))
744 744  
973 +(((
745 745  **0xAD 00**  **~-~->** Same as AT+DATAUP=0
975 +)))
746 746  
977 +(((
747 747  **0xAD 01**  **~-~->** Same as AT+DATAUP=1
979 +)))
748 748  
749 749  
750 750  
983 +
751 751  ==== **Manually trigger an Uplink** ====
752 752  
986 +(((
753 753  Ask device to send an uplink immediately.
988 +)))
754 754  
755 -* **AT Command:**
990 +* (((
991 +**AT Command:**
992 +)))
756 756  
757 -No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same.
994 +(((
995 +No AT Command for this, user can press the [[ACT button>>path:#H3.7Buttons]] for 1 second for the same.
996 +)))
758 758  
998 +(((
999 +
1000 +)))
759 759  
760 -* **Downlink Payload:**
1002 +* (((
1003 +**Downlink Payload:**
1004 +)))
761 761  
1006 +(((
762 762  **0x08 FF**, RS485-LN will immediately send an uplink.
1008 +)))
763 763  
764 764  
765 765  
1012 +
766 766  ==== **Clear RS485 Command** ====
767 767  
1015 +(((
768 768  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
1017 +)))
769 769  
770 -* **AT Command:**
1019 +* (((
1020 +**AT Command:**
1021 +)))
771 771  
1023 +(((
772 772  **AT+CMDEAR=mm,nn**   mm: start position of erase ,nn: stop position of erase
1025 +)))
773 773  
1027 +(((
774 774  Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
1029 +)))
775 775  
1031 +(((
776 776  Example screen shot after clear all RS485 commands. 
1033 +)))
777 777  
1035 +(((
1036 +
1037 +)))
778 778  
1039 +(((
779 779  The uplink screen shot is:
1041 +)))
780 780  
781 -[[image:1654160691922-496.png]]
1043 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654160691922-496.png?rev=1.1||alt="1654160691922-496.png"]]
782 782  
783 783  
784 -* **Downlink Payload:**
1046 +* (((
1047 +**Downlink Payload:**
1048 +)))
785 785  
1050 +(((
786 786  **0x09 aa bb** same as AT+CMDEAR=aa,bb
1052 +)))
787 787  
788 788  
789 789  
1056 +
790 790  ==== **Set Serial Communication Parameters** ====
791 791  
1059 +(((
792 792  Set the Rs485 serial communication parameters:
1061 +)))
793 793  
794 -* **AT Command:**
1063 +* (((
1064 +**AT Command:**
1065 +)))
795 795  
1067 +(((
796 796  Set Baud Rate:
1069 +)))
797 797  
798 798  (% class="box infomessage" %)
799 799  (((
1073 +(((
800 800  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
801 801  )))
1076 +)))
802 802  
1078 +(((
803 803  Set UART Parity
1080 +)))
804 804  
805 805  (% class="box infomessage" %)
806 806  (((
1084 +(((
807 807  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
808 808  )))
1087 +)))
809 809  
1089 +(((
810 810  Set STOPBIT
1091 +)))
811 811  
812 812  (% class="box infomessage" %)
813 813  (((
1095 +(((
814 814  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
815 815  )))
1098 +)))
816 816  
1100 +(((
1101 +
1102 +)))
817 817  
818 -* **Downlink Payload:**
1104 +* (((
1105 +**Downlink Payload:**
1106 +)))
819 819  
1108 +(((
820 820  **A7 01 aa bb**: Same  AT+BAUDR=hex(aa bb)*100
1110 +)))
821 821  
1112 +(((
822 822  **Example:**
1114 +)))
823 823  
824 -* A7 01 00 60   same as AT+BAUDR=9600
825 -* A7 01 04 80  same as AT+BAUDR=115200
1116 +* (((
1117 +A7 01 00 60   same as AT+BAUDR=9600
1118 +)))
1119 +* (((
1120 +A7 01 04 80  same as AT+BAUDR=115200
1121 +)))
826 826  
1123 +(((
827 827  A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1125 +)))
828 828  
1127 +(((
829 829  A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1129 +)))
830 830  
831 831  
1132 +
1133 +
832 832  == 3.6 Listening mode for RS485 network ==
833 833  
1136 +(((
834 834  This feature support since firmware v1.4
1138 +)))
835 835  
1140 +(((
836 836  RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN.
1142 +)))
837 837  
838 -[[image:image-20220602171200-8.png||height="567" width="1007"]]
1144 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-8.png?width=1007&height=567&rev=1.1||alt="image-20220602171200-8.png" height="567" width="1007"]]
839 839  
1146 +(((
840 840  To enable the listening mode, use can run the command AT+RXMODE.
1148 +)))
841 841  
1150 +(((
1151 +
1152 +)))
842 842  
843 -(% border="1" style="background-color:#ffffcc; width:500px" %)
844 -|=(% style="width: 161px;" %)**Command example:**|=(% style="width: 337px;" %)**Function**
845 -|(% style="width:161px" %)AT+RXMODE=1,10 |(% style="width:337px" %)Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
846 -|(% style="width:161px" %)AT+RXMODE=2,500|(% style="width:337px" %)Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
847 -|(% style="width:161px" %)AT+RXMODE=0,0|(% style="width:337px" %)Disable listening mode. This is the default settings.
848 -|(% style="width:161px" %) |(% style="width:337px" %)A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 ~| cc)
1154 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
1155 +|=(% style="width: 161px;" %)(((
1156 +**Command example:**
1157 +)))|=(% style="width: 337px;" %)(((
1158 +**Function**
1159 +)))
1160 +|(% style="width:161px" %)(((
1161 +AT+RXMODE=1,10
1162 +)))|(% style="width:337px" %)(((
1163 +Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
1164 +)))
1165 +|(% style="width:161px" %)(((
1166 +AT+RXMODE=2,500
1167 +)))|(% style="width:337px" %)(((
1168 +Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
1169 +)))
1170 +|(% style="width:161px" %)(((
1171 +AT+RXMODE=0,0
1172 +)))|(% style="width:337px" %)(((
1173 +Disable listening mode. This is the default settings.
1174 +)))
1175 +|(% style="width:161px" %)(((
1176 +
1177 +)))|(% style="width:337px" %)(((
1178 +A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 | cc)
1179 +)))
849 849  
1181 +(((
850 850  **Downlink Command:**
1183 +)))
851 851  
1185 +(((
852 852  **0xA6 aa bb cc ** same as AT+RXMODE=aa,(bb<<8 | cc)
1187 +)))
853 853  
1189 +(((
1190 +
1191 +)))
854 854  
1193 +(((
855 855  **Example**:
1195 +)))
856 856  
1197 +(((
857 857  The RS485-LN is set to AT+RXMODE=2,1000
1199 +)))
858 858  
1201 +(((
859 859  There is a two Modbus commands in the RS485 network as below:
1203 +)))
860 860  
1205 +(((
861 861  The Modbus master send a command: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b
1207 +)))
862 862  
1209 +(((
863 863  And Modbus slave reply with: (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33
1211 +)))
864 864  
1213 +(((
865 865  RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b  (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33
1215 +)))
866 866  
867 -[[image:image-20220602171200-9.png]]
1217 +(((
1218 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-9.png?rev=1.1||alt="image-20220602171200-9.png"]]
1219 +)))
868 868  
1221 +(((
1222 +
1223 +)))
869 869  
1225 +(((
870 870  (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
1227 +)))
871 871  
872 872  
873 873  == 3.7 Buttons ==
874 874  
875 875  
876 -(% border="1" style="background-color:#f7faff; width:500px" %)
877 -|=**Button**|=(% style="width: 1420px;" %)**Feature**
878 -|**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
879 -|**RST**|(% style="width:1420px" %)Reboot RS485
880 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1233 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1234 +|=(% style="width: 30px;" %)**Button**|=(% style="width: 355px;" %)**Feature**
1235 +|=(% style="width: 30px;" %)**ACT**|(% style="width:355px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1236 +|=(% style="width: 30px;" %)**RST**|(% style="width:355px" %)Reboot RS485
1237 +|=(% style="width: 30px;" %)**PRO**|(% style="width:355px" %)Use for upload image, see [[How to Update Image>>path:#H6.1Howtoupgradetheimage3F]]
881 881  
1239 +
882 882  == 3.8 LEDs ==
883 883  
884 -(% border="1" style="background-color:#f7faff; width:500px" %)
885 -|=**LEDs**|=**Feature**
886 -|**PWR**|Always on if there is power
887 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1242 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)
1243 +|=(% style="width: 30px;" %)**LEDs**|=(% style="width: 400px;" %)**Feature**
1244 +|(% style="width:30px" %)**PWR**|=(% style="width: 400px;" %)Always on if there is power
1245 +|(% style="width:30px" %)**SYS**|=(% style="width: 400px;" %)After device is powered on, the SYS will (% style="color:green" %)fast blink in GREEN (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)on GREEN for 5 seconds(%%). SYS will (% style="color:green" %)blink Blue(%%) on every upload and (% style="color:green" %)blink Green(%%) once receive a downlink message.
888 888  
1247 +
889 889  = 4. Case Study =
890 890  
891 -User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1250 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>path:/xwiki/bin/view/Main/Application%20Note%20%3A%20Communicate%20with%20Different%20Sensors%20-----%20RS485-LN%20%20RS485-BL/]]
892 892  
893 893  
894 894  = 5. Use AT Command =
... ... @@ -895,19 +895,26 @@
895 895  
896 896  == 5.1 Access AT Command ==
897 897  
1257 +(((
898 898  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1259 +)))
899 899  
900 -[[image:1654162355560-817.png]]
1261 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162355560-817.png?rev=1.1||alt="1654162355560-817.png"]]
901 901  
902 902  
1264 +(((
903 903  In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1266 +)))
904 904  
905 -[[image:1654162368066-342.png]]
1268 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162368066-342.png?rev=1.1||alt="1654162368066-342.png"]]
906 906  
907 907  
908 -More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1271 +(((
1272 +More detail AT Command manual can be found at [[AT Command Manual>>url:https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1273 +)))
909 909  
910 910  
1276 +
911 911  == 5.2 Common AT Command Sequence ==
912 912  
913 913  === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
... ... @@ -974,7 +974,7 @@
974 974  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
975 975  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
976 976  
977 -[[image:1654162478620-421.png]]
1343 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162478620-421.png?rev=1.1||alt="1654162478620-421.png"]]
978 978  
979 979  
980 980  = 6. FAQ =
... ... @@ -989,7 +989,7 @@
989 989  
990 990  Below shows the hardware connection for how to upload an image to RS485-LN:
991 991  
992 -[[image:1654162535040-878.png]]
1358 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162535040-878.png?rev=1.1||alt="1654162535040-878.png"]]
993 993  
994 994  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
995 995  
... ... @@ -1002,28 +1002,28 @@
1002 1002  )))
1003 1003  
1004 1004  
1005 -[[image:image-20220602175818-12.png]]
1371 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175818-12.png?rev=1.1||alt="image-20220602175818-12.png"]]
1006 1006  
1007 1007  
1008 -[[image:image-20220602175848-13.png]]
1374 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175848-13.png?rev=1.1||alt="image-20220602175848-13.png"]]
1009 1009  
1010 1010  
1011 -[[image:image-20220602175912-14.png]]
1377 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175912-14.png?rev=1.1||alt="image-20220602175912-14.png"]]
1012 1012  
1013 1013  
1014 1014  **Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1015 1015  
1016 -[[image:image-20220602175638-10.png]]
1382 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175638-10.png?rev=1.1||alt="image-20220602175638-10.png"]]
1017 1017  
1018 1018  
1019 1019  == 6.2 How to change the LoRa Frequency Bands/Region? ==
1020 1020  
1021 -User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
1387 +User can follow the introduction for [[how to upgrade image>>path:#H6.1Howtoupgradetheimage3F]]. When download the images, choose the required image file for download.
1022 1022  
1023 1023  
1024 1024  == 6.3 How many RS485-Slave can RS485-BL connects? ==
1025 1025  
1026 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1392 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#H3.3.3Configurereadcommandsforeachsampling]].
1027 1027  
1028 1028  
1029 1029  == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==
... ... @@ -1030,7 +1030,7 @@
1030 1030  
1031 1031  When user need to use with ChirpStack or TTI. Please set AT+RPL=4.
1032 1032  
1033 -Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]
1399 +Detail info check this link: [[Set Packet Receiving Response Level>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.23SetPacketReceivingResponseLevel]]
1034 1034  
1035 1035  
1036 1036  = 7. Trouble Shooting =
... ... @@ -1037,12 +1037,12 @@
1037 1037  
1038 1038  == 7.1 Downlink doesn’t work, how to solve it? ==
1039 1039  
1040 -Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]]
1406 +Please see this link for debug: [[LoRaWAN Communication Debug>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/]]
1041 1041  
1042 1042  
1043 1043  == 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? ==
1044 1044  
1045 -It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1411 +It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]]
1046 1046  
1047 1047  
1048 1048  = 8. Order Info =
... ... @@ -1062,7 +1062,6 @@
1062 1062  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1063 1063  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1064 1064  
1065 -
1066 1066  = 9.Packing Info =
1067 1067  
1068 1068  
... ... @@ -1079,7 +1079,6 @@
1079 1079  * Package Size / pcs : 14.5 x 8 x 5 cm
1080 1080  * Weight / pcs : 170g
1081 1081  
1082 -
1083 1083  = 10. FCC Caution for RS485LN-US915 =
1084 1084  
1085 1085  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0