From version < 58.3 >
edited by Xiaoling
on 2022/06/06 11:14
To version < 58.26 >
edited by Xiaoling
on 2022/06/06 11:27
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -548,142 +548,282 @@
548 548  
549 549  
550 550  
551 +
551 551  ==== **RS485 Debug Command** ====
552 552  
554 +(((
553 553  This command is used to configure the RS485 devices; they won’t be used during sampling.
556 +)))
554 554  
555 -* **AT Command**
558 +* (((
559 +**AT Command**
560 +)))
556 556  
557 557  (% class="box infomessage" %)
558 558  (((
564 +(((
559 559  **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
560 560  )))
567 +)))
561 561  
569 +(((
562 562  m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
571 +)))
563 563  
564 -* **Downlink Payload**
573 +* (((
574 +**Downlink Payload**
575 +)))
565 565  
577 +(((
566 566  Format: A8 MM NN XX XX XX XX YY
579 +)))
567 567  
581 +(((
568 568  Where:
583 +)))
569 569  
570 -* MM: 1: add CRC-16/MODBUS ; 0: no CRC
571 -* NN: The length of RS485 command
572 -* XX XX XX XX: RS485 command total NN bytes
573 -* YY: How many bytes will be uplink from the return of this RS485 command,
574 -** if YY=0, RS485-LN will execute the downlink command without uplink;
575 -** if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200
576 -** if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200.
585 +* (((
586 +MM: 1: add CRC-16/MODBUS ; 0: no CRC
587 +)))
588 +* (((
589 +NN: The length of RS485 command
590 +)))
591 +* (((
592 +XX XX XX XX: RS485 command total NN bytes
593 +)))
594 +* (((
595 +(((
596 +YY: How many bytes will be uplink from the return of this RS485 command,
597 +)))
577 577  
599 +* (((
600 +if YY=0, RS485-LN will execute the downlink command without uplink;
601 +)))
602 +* (((
603 +if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200
604 +)))
605 +* (((
606 +if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200.
607 +)))
608 +)))
609 +
610 +(((
578 578  **Example 1** ~-~-> Configure without ask for uplink (YY=0)
612 +)))
579 579  
614 +(((
580 580  To connect a Modbus Alarm with below commands.
616 +)))
581 581  
582 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
618 +* (((
619 +The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
620 +)))
583 583  
584 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
622 +* (((
623 +The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
624 +)))
585 585  
626 +(((
586 586  So if user want to use downlink command to control to RS485 Alarm, he can use:
628 +)))
587 587  
630 +(((
588 588  (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm
632 +)))
589 589  
634 +(((
590 590  (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm
636 +)))
591 591  
638 +(((
592 592  A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
640 +)))
593 593  
642 +(((
643 +
644 +)))
594 594  
646 +(((
595 595  **Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
648 +)))
596 596  
650 +(((
597 597  User in IoT server send a downlink command: (% style="color:#4f81bd" %)**A8 01 06 0A 08 00 04 00 01 YY**
652 +)))
598 598  
654 +(((
655 +
656 +)))
599 599  
658 +(((
600 600  RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:
660 +)))
601 601  
662 +(((
602 602   **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
664 +)))
603 603  
666 +(((
604 604   [[image:1654159460680-153.png]]
668 +)))
605 605  
606 606  
607 607  
672 +
608 608  ==== **Set Payload version** ====
609 609  
675 +(((
610 610  This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
677 +)))
611 611  
612 -* **AT Command:**
679 +* (((
680 +**AT Command:**
681 +)))
613 613  
614 614  (% class="box infomessage" %)
615 615  (((
685 +(((
616 616  **AT+PAYVER: Set PAYVER field = 1**
617 617  )))
688 +)))
618 618  
619 -* **Downlink Payload:**
690 +* (((
691 +**Downlink Payload:**
692 +)))
620 620  
694 +(((
621 621  **0xAE 01**  ~-~-> Set PAYVER field =  0x01
696 +)))
622 622  
698 +(((
623 623  **0xAE 0F**   ~-~-> Set PAYVER field =  0x0F
700 +)))
624 624  
625 625  
626 626  
704 +
627 627  ==== **Set RS485 Sampling Commands** ====
628 628  
707 +(((
629 629  AT+COMMANDx or AT+DATACUTx
709 +)))
630 630  
711 +(((
631 631  These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
713 +)))
632 632  
715 +(((
716 +
717 +)))
633 633  
634 -* **AT Command:**
719 +* (((
720 +**AT Command:**
721 +)))
635 635  
636 636  (% class="box infomessage" %)
637 637  (((
725 +(((
638 638  **AT+COMMANDx: Configure RS485 read command to sensor.**
639 639  )))
728 +)))
640 640  
641 641  (% class="box infomessage" %)
642 642  (((
732 +(((
643 643  **AT+DATACUTx: Configure how to handle return from RS485 devices.**
644 644  )))
735 +)))
645 645  
737 +(((
738 +
739 +)))
646 646  
647 -* **Downlink Payload:**
741 +* (((
742 +**Downlink Payload:**
743 +)))
648 648  
745 +(((
649 649  **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
747 +)))
650 650  
749 +(((
651 651  (% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
751 +)))
652 652  
753 +(((
653 653  Format: AF MM NN LL XX XX XX XX YY
755 +)))
654 654  
757 +(((
655 655  Where:
759 +)))
656 656  
657 -* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
658 -* NN:  0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
659 -* LL:  The length of AT+COMMAND or AT+DATACUT command
660 -* XX XX XX XX: AT+COMMAND or AT+DATACUT command
661 -* YY:  If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.
761 +* (((
762 +MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
763 +)))
764 +* (((
765 +NN:  0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
766 +)))
767 +* (((
768 +LL:  The length of AT+COMMAND or AT+DATACUT command
769 +)))
770 +* (((
771 +XX XX XX XX: AT+COMMAND or AT+DATACUT command
772 +)))
773 +* (((
774 +YY:  If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.
775 +)))
662 662  
777 +(((
663 663  **Example:**
779 +)))
664 664  
781 +(((
665 665  (% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1
783 +)))
666 666  
785 +(((
667 667  (% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10**
787 +)))
668 668  
789 +(((
669 669  (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10**
791 +)))
670 670  
671 671  
672 672  
795 +
673 673  ==== **Fast command to handle MODBUS device** ====
674 674  
798 +(((
675 675  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
800 +)))
676 676  
802 +(((
677 677  This command is valid since v1.3 firmware version
804 +)))
678 678  
806 +(((
679 679  AT+MBFUN can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore.
808 +)))
680 680  
810 +(((
811 +
812 +)))
681 681  
814 +(((
682 682  **Example:**
816 +)))
683 683  
684 -* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
685 -* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
686 -* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
818 +* (((
819 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
820 +)))
821 +* (((
822 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
823 +)))
824 +* (((
825 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
826 +)))
687 687  
688 688  [[image:image-20220602165351-6.png]]
689 689  
... ... @@ -691,201 +691,376 @@
691 691  
692 692  
693 693  
834 +
694 694  ==== **RS485 command timeout** ====
695 695  
837 +(((
696 696  Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
839 +)))
697 697  
841 +(((
698 698  Default value: 0, range:  0 ~~ 65 seconds
843 +)))
699 699  
700 -* **AT Command:**
845 +* (((
846 +**AT Command:**
847 +)))
701 701  
702 702  (% class="box infomessage" %)
703 703  (((
851 +(((
704 704  **AT+CMDDLaa=hex(bb cc)*1000**
705 705  )))
854 +)))
706 706  
856 +(((
707 707  **Example:**
858 +)))
708 708  
860 +(((
709 709  **AT+CMDDL1=1000** to send the open time to 1000ms
862 +)))
710 710  
864 +(((
865 +
866 +)))
711 711  
712 -* **Downlink Payload:**
868 +* (((
869 +**Downlink Payload:**
870 +)))
713 713  
872 +(((
714 714  **0x AA aa bb cc**
874 +)))
715 715  
876 +(((
716 716  Same as: AT+CMDDLaa=hex(bb cc)*1000
878 +)))
717 717  
880 +(((
718 718   **Example:**
882 +)))
719 719  
884 +(((
720 720   0xAA 01 00 01  ~-~-> Same as **AT+CMDDL1=1000 ms**
886 +)))
721 721  
722 722  
723 723  
890 +
724 724  ==== **Uplink payload mode** ====
725 725  
893 +(((
726 726  Define to use one uplink or multiple uplinks for the sampling.
895 +)))
727 727  
897 +(((
728 728  The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
899 +)))
729 729  
730 -* **AT Command:**
901 +* (((
902 +**AT Command:**
903 +)))
731 731  
732 732  (% class="box infomessage" %)
733 733  (((
907 +(((
734 734  **AT+DATAUP=0**
735 735  )))
910 +)))
736 736  
737 737  (% class="box infomessage" %)
738 738  (((
914 +(((
739 739  **AT+DATAUP=1**
740 740  )))
917 +)))
741 741  
919 +(((
920 +
921 +)))
742 742  
743 -* **Downlink Payload:**
923 +* (((
924 +**Downlink Payload:**
925 +)))
744 744  
927 +(((
745 745  **0xAD 00**  **~-~->** Same as AT+DATAUP=0
929 +)))
746 746  
931 +(((
747 747  **0xAD 01**  **~-~->** Same as AT+DATAUP=1
933 +)))
748 748  
749 749  
750 750  
937 +
751 751  ==== **Manually trigger an Uplink** ====
752 752  
940 +(((
753 753  Ask device to send an uplink immediately.
942 +)))
754 754  
755 -* **AT Command:**
944 +* (((
945 +**AT Command:**
946 +)))
756 756  
948 +(((
757 757  No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same.
950 +)))
758 758  
952 +(((
953 +
954 +)))
759 759  
760 -* **Downlink Payload:**
956 +* (((
957 +**Downlink Payload:**
958 +)))
761 761  
960 +(((
762 762  **0x08 FF**, RS485-LN will immediately send an uplink.
962 +)))
763 763  
764 764  
765 765  
966 +
766 766  ==== **Clear RS485 Command** ====
767 767  
969 +(((
768 768  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
971 +)))
769 769  
770 -* **AT Command:**
973 +* (((
974 +**AT Command:**
975 +)))
771 771  
977 +(((
772 772  **AT+CMDEAR=mm,nn**   mm: start position of erase ,nn: stop position of erase
979 +)))
773 773  
981 +(((
774 774  Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
983 +)))
775 775  
985 +(((
776 776  Example screen shot after clear all RS485 commands. 
987 +)))
777 777  
989 +(((
990 +
991 +)))
778 778  
993 +(((
779 779  The uplink screen shot is:
995 +)))
780 780  
781 781  [[image:1654160691922-496.png]]
782 782  
783 783  
784 -* **Downlink Payload:**
1000 +* (((
1001 +**Downlink Payload:**
1002 +)))
785 785  
1004 +(((
786 786  **0x09 aa bb** same as AT+CMDEAR=aa,bb
1006 +)))
787 787  
788 788  
789 789  
1010 +
790 790  ==== **Set Serial Communication Parameters** ====
791 791  
1013 +(((
792 792  Set the Rs485 serial communication parameters:
1015 +)))
793 793  
794 -* **AT Command:**
1017 +* (((
1018 +**AT Command:**
1019 +)))
795 795  
1021 +(((
796 796  Set Baud Rate:
1023 +)))
797 797  
798 798  (% class="box infomessage" %)
799 799  (((
1027 +(((
800 800  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
801 801  )))
1030 +)))
802 802  
1032 +(((
803 803  Set UART Parity
1034 +)))
804 804  
805 805  (% class="box infomessage" %)
806 806  (((
1038 +(((
807 807  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
808 808  )))
1041 +)))
809 809  
1043 +(((
810 810  Set STOPBIT
1045 +)))
811 811  
812 812  (% class="box infomessage" %)
813 813  (((
1049 +(((
814 814  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
815 815  )))
1052 +)))
816 816  
1054 +(((
1055 +
1056 +)))
817 817  
818 -* **Downlink Payload:**
1058 +* (((
1059 +**Downlink Payload:**
1060 +)))
819 819  
1062 +(((
820 820  **A7 01 aa bb**: Same  AT+BAUDR=hex(aa bb)*100
1064 +)))
821 821  
1066 +(((
822 822  **Example:**
1068 +)))
823 823  
824 -* A7 01 00 60   same as AT+BAUDR=9600
825 -* A7 01 04 80  same as AT+BAUDR=115200
1070 +* (((
1071 +A7 01 00 60   same as AT+BAUDR=9600
1072 +)))
1073 +* (((
1074 +A7 01 04 80  same as AT+BAUDR=115200
1075 +)))
826 826  
1077 +(((
827 827  A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1079 +)))
828 828  
1081 +(((
829 829  A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1083 +)))
830 830  
831 831  
1086 +
1087 +
832 832  == 3.6 Listening mode for RS485 network ==
833 833  
1090 +(((
834 834  This feature support since firmware v1.4
1092 +)))
835 835  
1094 +(((
836 836  RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN.
1096 +)))
837 837  
838 838  [[image:image-20220602171200-8.png||height="567" width="1007"]]
839 839  
1100 +(((
840 840  To enable the listening mode, use can run the command AT+RXMODE.
1102 +)))
841 841  
1104 +(((
1105 +
1106 +)))
842 842  
843 -(% border="1" style="background-color:#ffffcc; width:500px" %)
844 -|=(% style="width: 161px;" %)**Command example:**|=(% style="width: 337px;" %)**Function**
845 -|(% style="width:161px" %)AT+RXMODE=1,10 |(% style="width:337px" %)Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
846 -|(% style="width:161px" %)AT+RXMODE=2,500|(% style="width:337px" %)Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
847 -|(% style="width:161px" %)AT+RXMODE=0,0|(% style="width:337px" %)Disable listening mode. This is the default settings.
848 -|(% style="width:161px" %) |(% style="width:337px" %)A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 ~| cc)
1108 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
1109 +|=(% style="width: 161px;" %)(((
1110 +**Command example:**
1111 +)))|=(% style="width: 337px;" %)(((
1112 +**Function**
1113 +)))
1114 +|(% style="width:161px" %)(((
1115 +AT+RXMODE=1,10
1116 +)))|(% style="width:337px" %)(((
1117 +Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
1118 +)))
1119 +|(% style="width:161px" %)(((
1120 +AT+RXMODE=2,500
1121 +)))|(% style="width:337px" %)(((
1122 +Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
1123 +)))
1124 +|(% style="width:161px" %)(((
1125 +AT+RXMODE=0,0
1126 +)))|(% style="width:337px" %)(((
1127 +Disable listening mode. This is the default settings.
1128 +)))
1129 +|(% style="width:161px" %)(((
1130 +
1131 +)))|(% style="width:337px" %)(((
1132 +A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 | cc)
1133 +)))
849 849  
1135 +(((
850 850  **Downlink Command:**
1137 +)))
851 851  
1139 +(((
852 852  **0xA6 aa bb cc ** same as AT+RXMODE=aa,(bb<<8 | cc)
1141 +)))
853 853  
1143 +(((
1144 +
1145 +)))
854 854  
1147 +(((
855 855  **Example**:
1149 +)))
856 856  
1151 +(((
857 857  The RS485-LN is set to AT+RXMODE=2,1000
1153 +)))
858 858  
1155 +(((
859 859  There is a two Modbus commands in the RS485 network as below:
1157 +)))
860 860  
1159 +(((
861 861  The Modbus master send a command: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b
1161 +)))
862 862  
1163 +(((
863 863  And Modbus slave reply with: (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33
1165 +)))
864 864  
1167 +(((
865 865  RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b  (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33
1169 +)))
866 866  
1171 +(((
867 867  [[image:image-20220602171200-9.png]]
1173 +)))
868 868  
1175 +(((
1176 +
1177 +)))
869 869  
1179 +(((
870 870  (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
1181 +)))
871 871  
872 872  
873 873  == 3.7 Buttons ==
874 874  
875 875  
876 -(% border="1" style="background-color:#f7faff; width:500px" %)
1187 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)
877 877  |=**Button**|=(% style="width: 1420px;" %)**Feature**
878 878  |**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
879 879  |**RST**|(% style="width:1420px" %)Reboot RS485
880 880  |**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
881 881  
1193 +
1194 +
882 882  == 3.8 LEDs ==
883 883  
884 -(% border="1" style="background-color:#f7faff; width:500px" %)
1197 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)
885 885  |=**LEDs**|=**Feature**
886 886  |**PWR**|Always on if there is power
887 887  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
888 888  
1202 +
1203 +
889 889  = 4. Case Study =
890 890  
891 891  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -895,17 +895,23 @@
895 895  
896 896  == 5.1 Access AT Command ==
897 897  
1213 +(((
898 898  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1215 +)))
899 899  
900 900  [[image:1654162355560-817.png]]
901 901  
902 902  
1220 +(((
903 903  In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1222 +)))
904 904  
905 905  [[image:1654162368066-342.png]]
906 906  
907 907  
1227 +(((
908 908  More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1229 +)))
909 909  
910 910  
911 911  == 5.2 Common AT Command Sequence ==
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0