From version < 58.3 >
edited by Xiaoling
on 2022/06/06 11:14
To version < 57.48 >
edited by Xiaoling
on 2022/06/06 11:01
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -327,8 +327,6 @@
327 327  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
328 328  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
329 329  
330 -
331 -
332 332  === 3.3.3 Configure read commands for each sampling ===
333 333  
334 334  (((
... ... @@ -501,35 +501,33 @@
501 501  
502 502  == 3.4 Uplink Payload ==
503 503  
502 +(% border="1" style="background-color:#4bacc6; color:white; width:734px" %)
503 +|**Size(bytes)**|(% style="width:120px" %)**2**|(% style="width:116px" %)**1**|(% style="width:386px" %)**Length depends on the return from the commands**
504 +|Value|(% style="width:120px" %)(((
505 +Battery(mV)
504 504  
505 -[[image:image-20220606110929-1.png]]
507 +&
506 506  
509 +Interrupt _Flag
510 +)))|(% style="width:116px" %)(((
511 +PAYLOAD_VER
512 +
513 +
514 +)))|(% style="width:386px" %)If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server.
515 +
507 507  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
508 508  
509 509  
510 510  == 3.5 Configure RS485-BL via AT or Downlink ==
511 511  
512 -(((
513 513  User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands
514 -)))
515 515  
516 -(((
517 517  There are two kinds of Commands:
518 -)))
519 519  
520 -* (((
521 -(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
522 -)))
525 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
523 523  
524 -* (((
525 -(% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
526 -)))
527 +* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
527 527  
528 -(((
529 -
530 -)))
531 -
532 -
533 533  === 3.5.1 Common Commands ===
534 534  
535 535  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]