Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -103,6 +103,7 @@ 103 103 * Support Modbus protocol 104 104 * Support Interrupt uplink (Since hardware version v1.2) 105 105 106 + 106 106 == 1.4 Applications == 107 107 108 108 * Smart Buildings & Home Automation ... ... @@ -112,6 +112,7 @@ 112 112 * Smart Cities 113 113 * Smart Factory 114 114 116 + 115 115 == 1.5 Firmware Change log == 116 116 117 117 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -305,6 +305,8 @@ 305 305 ))) 306 306 ))) 307 307 310 + 311 + 308 308 === 3.3.2 Configure sensors === 309 309 310 310 ((( ... ... @@ -323,6 +323,8 @@ 323 323 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 324 324 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 325 325 330 + 331 + 326 326 === 3.3.3 Configure read commands for each sampling === 327 327 328 328 ((( ... ... @@ -1178,21 +1178,23 @@ 1178 1178 == 3.7 Buttons == 1179 1179 1180 1180 1181 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)1182 -|= (% style="width: 30px;" %)**Button**|=(% style="width:355px;" %)**Feature**1183 -| =(% style="width: 30px;" %)**ACT**|(% style="width:355px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**1184 -| =(% style="width: 30px;" %)**RST**|(% style="width:355px" %)Reboot RS4851185 -| =(% style="width: 30px;" %)**PRO**|(% style="width:355px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]1187 +(% border="1" style="background-color:#f7faff; width:500px" %) 1188 +|=**Button**|=(% style="width: 1420px;" %)**Feature** 1189 +|**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 1190 +|**RST**|(% style="width:1420px" %)Reboot RS485 1191 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1186 1186 1187 1187 1188 1188 1189 1189 == 3.8 LEDs == 1190 1190 1191 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)1192 -|= (% style="width: 30px;" %)**LEDs**|=(% style="width: 400px;" %)**Feature**1193 -| (% style="width:30px" %)**PWR**|=(% style="width: 400px;" %)Always on if there is power1194 -| (% style="width:30px" %)**SYS**|=(% style="width: 400px;" %)After device is powered on, the SYS will (% style="color:green" %)fast blink in GREEN (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)on GREEN for 5 seconds(%%).1197 +(% border="1" style="background-color:#f7faff; width:500px" %) 1198 +|=**LEDs**|=**Feature** 1199 +|**PWR**|Always on if there is power 1200 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1195 1195 1202 + 1203 + 1196 1196 = 4. Case Study = 1197 1197 1198 1198 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -1202,26 +1202,19 @@ 1202 1202 1203 1203 == 5.1 Access AT Command == 1204 1204 1205 -((( 1206 1206 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1207 -))) 1208 1208 1209 1209 [[image:1654162355560-817.png]] 1210 1210 1211 1211 1212 -((( 1213 1213 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1214 -))) 1215 1215 1216 1216 [[image:1654162368066-342.png]] 1217 1217 1218 1218 1219 -((( 1220 1220 More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1221 -))) 1222 1222 1223 1223 1224 - 1225 1225 == 5.2 Common AT Command Sequence == 1226 1226 1227 1227 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === ... ... @@ -1376,6 +1376,7 @@ 1376 1376 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1377 1377 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1378 1378 1380 + 1379 1379 = 9.Packing Info = 1380 1380 1381 1381 ... ... @@ -1392,6 +1392,7 @@ 1392 1392 * Package Size / pcs : 14.5 x 8 x 5 cm 1393 1393 * Weight / pcs : 170g 1394 1394 1397 + 1395 1395 = 10. FCC Caution for RS485LN-US915 = 1396 1396 1397 1397 (((