Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -RS485-LN – RS485 to LoRaWAN Converter 1 +RS485-LN – RS485 to LoRaWAN Converter User Manual - Content
-
... ... @@ -3,7 +3,6 @@ 3 3 4 4 5 5 6 -**RS485-LN – RS485 to LoRaWAN Converter User Manual** 7 7 8 8 9 9 ... ... @@ -25,6 +25,8 @@ 25 25 ((( 26 26 ((( 27 27 ((( 27 + 28 + 28 28 The Dragino RS485-LN is a (% style="color:blue" %)**RS485 to LoRaWAN Converter**(%%). It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost. 29 29 ))) 30 30 ))) ... ... @@ -48,6 +48,8 @@ 48 48 49 49 ((( 50 50 (% style="color:blue" %)**Demo Dashboard for RS485-LN**(%%) connect to two energy meters: [[https:~~/~~/app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a>>url:https://app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a]] 52 + 53 + 51 51 ))) 52 52 ))) 53 53 ))) ... ... @@ -92,6 +92,9 @@ 92 92 * Automatic RF Sense and CAD with ultra-fast AFC. 93 93 * Packet engine up to 256 bytes with CRC 94 94 98 + 99 + 100 + 95 95 == 1.3 Features == 96 96 97 97 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -103,7 +103,6 @@ 103 103 * Support Modbus protocol 104 104 * Support Interrupt uplink (Since hardware version v1.2) 105 105 106 - 107 107 == 1.4 Applications == 108 108 109 109 * Smart Buildings & Home Automation ... ... @@ -113,7 +113,6 @@ 113 113 * Smart Cities 114 114 * Smart Factory 115 115 116 - 117 117 == 1.5 Firmware Change log == 118 118 119 119 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -182,12 +182,13 @@ 182 182 183 183 [[image:1653268227651-549.png||height="592" width="720"]] 184 184 189 + 185 185 ((( 186 186 The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3: 187 187 ))) 188 188 189 189 ((( 190 -**Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-LN. 195 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN V3 with the OTAA keys from RS485-LN. 191 191 ))) 192 192 193 193 ((( ... ... @@ -197,6 +197,7 @@ 197 197 198 198 [[image:1652953462722-299.png]] 199 199 205 + 200 200 ((( 201 201 ((( 202 202 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot: ... ... @@ -203,7 +203,7 @@ 203 203 ))) 204 204 205 205 ((( 206 -Add APP EUI in the application. 212 +**Add APP EUI in the application.** 207 207 ))) 208 208 ))) 209 209 ... ... @@ -219,13 +219,15 @@ 219 219 220 220 [[image:1652953542269-423.png||height="710" width="723"]] 221 221 222 -Add APP KEY and DEV EUI 223 223 229 + 230 +**Add APP KEY and DEV EUI** 231 + 224 224 [[image:1652953553383-907.png||height="514" width="724"]] 225 225 226 226 227 227 ((( 228 -**Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 236 +(% style="color:blue" %)**Step 2**(%%): Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 229 229 ))) 230 230 231 231 [[image:1652953568895-172.png||height="232" width="724"]] ... ... @@ -235,11 +235,15 @@ 235 235 236 236 ((( 237 237 ((( 238 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 246 +((( 247 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-LNviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 239 239 ))) 249 +))) 240 240 241 241 ((( 252 +((( 242 242 (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 254 +))) 243 243 244 244 245 245 ))) ... ... @@ -308,7 +308,6 @@ 308 308 ))) 309 309 310 310 311 - 312 312 === 3.3.2 Configure sensors === 313 313 314 314 ((( ... ... @@ -320,15 +320,20 @@ 320 320 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 321 321 |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 322 322 |AT+CFGDEV|(% style="width:110px" %)((( 334 +((( 323 323 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 336 +))) 324 324 338 +((( 325 325 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 340 +))) 326 326 342 +((( 327 327 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 344 +))) 328 328 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 329 329 330 330 331 - 332 332 === 3.3.3 Configure read commands for each sampling === 333 333 334 334 ((( ... ... @@ -341,7 +341,7 @@ 341 341 During each sampling, the RS485-LN can support 15 commands to read sensors. And combine the return to one or several uplink payloads. 342 342 343 343 344 -**Each RS485 commands include two parts:** 360 +(% style="color:#037691" %)**Each RS485 commands include two parts:** 345 345 346 346 ~1. What commands RS485-LN will send to the RS485 sensors. There are total 15 commands from **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF**. All commands are of same grammar. 347 347 ... ... @@ -356,11 +356,11 @@ 356 356 Below are examples for the how above AT Commands works. 357 357 358 358 359 -**AT+COMMANDx : **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is: 375 +(% style="color:#037691" %)**AT+COMMANDx **(%%)**: **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is: 360 360 361 361 (% border="1" style="background-color:#4bacc6; color:white; width:499px" %) 362 362 |(% style="width:496px" %)((( 363 -**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 379 +(% style="color:#037691" %)**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 364 364 365 365 **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent** 366 366 ... ... @@ -372,7 +372,7 @@ 372 372 In the RS485-LN, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same. 373 373 374 374 375 -**AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes. 391 +(% style="color:#037691" %)**AT+DATACUTx **(%%)**: **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes. 376 376 377 377 (% border="1" style="background-color:#4bacc6; color:white; width:510px" %) 378 378 |(% style="width:510px" %)((( ... ... @@ -385,20 +385,21 @@ 385 385 386 386 **Examples:** 387 387 388 -* Grab bytes :404 +* (% style="color:#037691" %)**Grab bytes** 389 389 390 390 [[image:image-20220602153621-1.png]] 391 391 392 392 393 -* Grab a section .409 +* (% style="color:#037691" %)**Grab a section** 394 394 395 395 [[image:image-20220602153621-2.png]] 396 396 397 397 398 -* Grab different sections .414 +* (% style="color:#037691" %)**Grab different sections** 399 399 400 400 [[image:image-20220602153621-3.png]] 401 401 418 + 402 402 403 403 ))) 404 404 ... ... @@ -507,7 +507,7 @@ 507 507 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 508 508 509 509 510 -== 3.5 Configure RS485- BL via AT or Downlink ==527 +== 3.5 Configure RS485-LN via AT or Downlink == 511 511 512 512 ((( 513 513 User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands ... ... @@ -673,7 +673,7 @@ 673 673 ==== **Set Payload version** ==== 674 674 675 675 ((( 676 -This is the first byte of the uplink payload. RS485- BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.693 +This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 677 677 ))) 678 678 679 679 * ((( ... ... @@ -771,7 +771,7 @@ 771 771 XX XX XX XX: AT+COMMAND or AT+DATACUT command 772 772 ))) 773 773 * ((( 774 -YY: If YY=0, RS485- BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.791 +YY: If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 775 775 ))) 776 776 777 777 ((( ... ... @@ -1106,29 +1106,29 @@ 1106 1106 ))) 1107 1107 1108 1108 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1109 -|=(% style="width: 1 61px;" %)(((1110 -**Command example :**1111 -)))|=(% style="width: 337px;" %)(((1126 +|=(% style="width: 100px;" %)((( 1127 +**Command example** 1128 +)))|=(% style="width: 400px;" %)((( 1112 1112 **Function** 1113 1113 ))) 1114 -|(% style="width:1 61px" %)(((1131 +|(% style="width:100px" %)((( 1115 1115 AT+RXMODE=1,10 1116 -)))|(% style="width: 337px" %)(((1133 +)))|(% style="width:400px" %)((( 1117 1117 Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1118 1118 ))) 1119 -|(% style="width:1 61px" %)(((1136 +|(% style="width:100px" %)((( 1120 1120 AT+RXMODE=2,500 1121 -)))|(% style="width: 337px" %)(((1138 +)))|(% style="width:400px" %)((( 1122 1122 Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1123 1123 ))) 1124 -|(% style="width:1 61px" %)(((1141 +|(% style="width:100px" %)((( 1125 1125 AT+RXMODE=0,0 1126 -)))|(% style="width: 337px" %)(((1143 +)))|(% style="width:400px" %)((( 1127 1127 Disable listening mode. This is the default settings. 1128 1128 ))) 1129 -|(% style="width:1 61px" %)(((1146 +|(% style="width:100px" %)((( 1130 1130 1131 -)))|(% style="width: 337px" %)(((1148 +)))|(% style="width:400px" %)((( 1132 1132 A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1133 1133 ))) 1134 1134 ... ... @@ -1177,30 +1177,29 @@ 1177 1177 ))) 1178 1178 1179 1179 ((( 1197 +((( 1180 1180 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1181 1181 ))) 1200 +))) 1182 1182 1183 1183 1184 1184 == 3.7 Buttons == 1185 1185 1186 1186 1187 -(% border="1" cellspacing="10" style="background-color:#f7faff; width: 500px" %)1188 -|=**Button**|=(% style="width: 1 420px;" %)**Feature**1189 -|**ACT**|(% style="width:1 420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**1190 -|**RST**|(% style="width:1 420px" %)Reboot RS4851191 -|**PRO**|(% style="width:1 420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]1206 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1207 +|=(% style="width: 50px;" %)**Button**|=(% style="width: 361px;" %)**Feature** 1208 +|(% style="width:50px" %)**ACT**|(% style="width:361px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 1209 +|(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485 1210 +|(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1192 1192 1193 - 1194 - 1195 1195 == 3.8 LEDs == 1196 1196 1197 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %) 1198 -|=**LEDs**|=**Feature** 1214 + 1215 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1216 +|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature** 1199 1199 |**PWR**|Always on if there is power 1200 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink 1218 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1201 1201 1202 - 1203 - 1204 1204 = 4. Case Study = 1205 1205 1206 1206 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -1211,7 +1211,7 @@ 1211 1211 == 5.1 Access AT Command == 1212 1212 1213 1213 ((( 1214 -RS485- BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.1230 +RS485-LN supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-LN to use AT command, as below. 1215 1215 ))) 1216 1216 1217 1217 [[image:1654162355560-817.png]] ... ... @@ -1218,7 +1218,7 @@ 1218 1218 1219 1219 1220 1220 ((( 1221 -In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485- BL. The default password is 123456. Below is the output for reference:1237 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-LN. The default password is 123456. Below is the output for reference: 1222 1222 ))) 1223 1223 1224 1224 [[image:1654162368066-342.png]] ... ... @@ -1252,7 +1252,9 @@ 1252 1252 ))) 1253 1253 1254 1254 1271 +((( 1255 1255 If device already joined network: 1273 +))) 1256 1256 1257 1257 (% class="box infomessage" %) 1258 1258 ((( ... ... @@ -1291,10 +1291,12 @@ 1291 1291 1292 1292 (% style="color:red" %)**Note:** 1293 1293 1312 +((( 1294 1294 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1295 1295 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1296 1296 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1297 1297 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1317 +))) 1298 1298 1299 1299 [[image:1654162478620-421.png]] 1300 1300 ... ... @@ -1303,25 +1303,45 @@ 1303 1303 1304 1304 == 6.1 How to upgrade the image? == 1305 1305 1326 +((( 1306 1306 The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to: 1328 +))) 1307 1307 1308 -* Support new features 1309 -* For bug fix 1310 -* Change LoRaWAN bands. 1330 +* ((( 1331 +Support new features 1332 +))) 1333 +* ((( 1334 +For bug fix 1335 +))) 1336 +* ((( 1337 +Change LoRaWAN bands. 1338 +))) 1311 1311 1340 +((( 1312 1312 Below shows the hardware connection for how to upload an image to RS485-LN: 1342 +))) 1313 1313 1314 1314 [[image:1654162535040-878.png]] 1315 1315 1346 +((( 1316 1316 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1348 +))) 1317 1317 1350 +((( 1318 1318 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1352 +))) 1319 1319 1354 +((( 1320 1320 **Step3: **Open flashloader; choose the correct COM port to update. 1356 +))) 1321 1321 1322 1322 ((( 1359 +((( 1360 +((( 1323 1323 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 1324 1324 ))) 1363 +))) 1364 +))) 1325 1325 1326 1326 1327 1327 [[image:image-20220602175818-12.png]] ... ... @@ -1343,9 +1343,9 @@ 1343 1343 User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download. 1344 1344 1345 1345 1346 -== 6.3 How many RS485-Slave can RS485- BL connects? ==1386 +== 6.3 How many RS485-Slave can RS485-LN connects? == 1347 1347 1348 -The RS485- BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].1388 +The RS485-LN can support max 32 RS485 devices. Each uplink command of RS485-LN can support max 16 different RS485 command. So RS485-LN can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 1349 1349 1350 1350 1351 1351 == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? == ... ... @@ -1384,7 +1384,6 @@ 1384 1384 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1385 1385 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1386 1386 1387 - 1388 1388 = 9.Packing Info = 1389 1389 1390 1390 ... ... @@ -1401,7 +1401,6 @@ 1401 1401 * Package Size / pcs : 14.5 x 8 x 5 cm 1402 1402 * Weight / pcs : 170g 1403 1403 1404 - 1405 1405 = 10. FCC Caution for RS485LN-US915 = 1406 1406 1407 1407 (((