... ... @@ -103,7 +103,6 @@
103 103  * Support Modbus protocol
104 104  * Support Interrupt uplink (Since hardware version v1.2)
105 105  
106 -
107 107  == 1.4 Applications ==
108 108  
109 109  * Smart Buildings & Home Automation
... ... @@ -113,7 +113,6 @@
113 113  * Smart Cities
114 114  * Smart Factory
115 115  
116 -
117 117  == 1.5 Firmware Change log ==
118 118  
119 119  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -235,11 +235,15 @@
235 235  
236 236  (((
237 237  (((
236 +(((
238 238  There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
239 239  )))
239 +)))
240 240  
241 241  (((
242 +(((
242 242  (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1
244 +)))
243 243  
244 244  
245 245  )))
... ... @@ -308,7 +308,6 @@
308 308  )))
309 309  
310 310  
311 -
312 312  === 3.3.2 Configure sensors ===
313 313  
314 314  (((
... ... @@ -320,15 +320,20 @@
320 320  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
321 321  |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
322 322  |AT+CFGDEV|(% style="width:110px" %)(((
324 +(((
323 323  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
326 +)))
324 324  
328 +(((
325 325  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
330 +)))
326 326  
332 +(((
327 327  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
334 +)))
328 328  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
329 329  
330 330  
331 -
332 332  === 3.3.3 Configure read commands for each sampling ===
333 333  
334 334  (((
... ... @@ -1106,29 +1106,29 @@
1106 1106  )))
1107 1107  
1108 1108  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
1109 -|=(% style="width: 161px;" %)(((
1110 -**Command example:**
1111 -)))|=(% style="width: 337px;" %)(((
1115 +|=(% style="width: 100px;" %)(((
1116 +**Command example**
1117 +)))|=(% style="width: 400px;" %)(((
1112 1112  **Function**
1113 1113  )))
1114 -|(% style="width:161px" %)(((
1120 +|(% style="width:100px" %)(((
1115 1115  AT+RXMODE=1,10
1116 -)))|(% style="width:337px" %)(((
1122 +)))|(% style="width:400px" %)(((
1117 1117  Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
1118 1118  )))
1119 -|(% style="width:161px" %)(((
1125 +|(% style="width:100px" %)(((
1120 1120  AT+RXMODE=2,500
1121 -)))|(% style="width:337px" %)(((
1127 +)))|(% style="width:400px" %)(((
1122 1122  Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
1123 1123  )))
1124 -|(% style="width:161px" %)(((
1130 +|(% style="width:100px" %)(((
1125 1125  AT+RXMODE=0,0
1126 -)))|(% style="width:337px" %)(((
1132 +)))|(% style="width:400px" %)(((
1127 1127  Disable listening mode. This is the default settings.
1128 1128  )))
1129 -|(% style="width:161px" %)(((
1135 +|(% style="width:100px" %)(((
1130 1130  
1131 -)))|(% style="width:337px" %)(((
1137 +)))|(% style="width:400px" %)(((
1132 1132  A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 | cc)
1133 1133  )))
1134 1134  
... ... @@ -1177,30 +1177,31 @@
1177 1177  )))
1178 1178  
1179 1179  (((
1186 +(((
1180 1180  (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
1181 1181  )))
1189 +)))
1182 1182  
1183 1183  
1184 1184  == 3.7 Buttons ==
1185 1185  
1186 1186  
1187 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)
1188 -|=**Button**|=(% style="width: 1420px;" %)**Feature**
1189 -|**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1190 -|**RST**|(% style="width:1420px" %)Reboot RS485
1191 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1195 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:400px" %)
1196 +|=(% style="width: 50px;" %)**Button**|=(% style="width: 350px;" %)**Feature**
1197 +|(% style="width:50px" %)**ACT**|(% style="width:350px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1198 +|(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485
1199 +|(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1192 1192  
1193 1193  
1194 -
1195 1195  == 3.8 LEDs ==
1196 1196  
1197 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)
1198 -|=**LEDs**|=**Feature**
1204 +
1205 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1206 +|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature**
1199 1199  |**PWR**|Always on if there is power
1200 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1208 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1201 1201  
1202 1202  
1203 -
1204 1204  = 4. Case Study =
1205 1205  
1206 1206  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1224,9 +1224,12 @@
1224 1224  [[image:1654162368066-342.png]]
1225 1225  
1226 1226  
1234 +(((
1227 1227  More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1236 +)))
1228 1228  
1229 1229  
1239 +
1230 1230  == 5.2 Common AT Command Sequence ==
1231 1231  
1232 1232  === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
... ... @@ -1249,7 +1249,9 @@
1249 1249  )))
1250 1250  
1251 1251  
1262 +(((
1252 1252  If device already joined network:
1264 +)))
1253 1253  
1254 1254  (% class="box infomessage" %)
1255 1255  (((
... ... @@ -1288,10 +1288,12 @@
1288 1288  
1289 1289  (% style="color:red" %)**Note:**
1290 1290  
1303 +(((
1291 1291  (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server.
1292 1292  2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1293 1293  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1294 1294  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1308 +)))
1295 1295  
1296 1296  [[image:1654162478620-421.png]]
1297 1297  
... ... @@ -1300,25 +1300,45 @@
1300 1300  
1301 1301  == 6.1 How to upgrade the image? ==
1302 1302  
1317 +(((
1303 1303  The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to:
1319 +)))
1304 1304  
1305 -* Support new features
1306 -* For bug fix
1307 -* Change LoRaWAN bands.
1321 +* (((
1322 +Support new features
1323 +)))
1324 +* (((
1325 +For bug fix
1326 +)))
1327 +* (((
1328 +Change LoRaWAN bands.
1329 +)))
1308 1308  
1331 +(((
1309 1309  Below shows the hardware connection for how to upload an image to RS485-LN:
1333 +)))
1310 1310  
1311 1311  [[image:1654162535040-878.png]]
1312 1312  
1337 +(((
1313 1313  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1339 +)))
1314 1314  
1341 +(((
1315 1315  **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1343 +)))
1316 1316  
1345 +(((
1317 1317  **Step3: **Open flashloader; choose the correct COM port to update.
1347 +)))
1318 1318  
1319 1319  (((
1350 +(((
1351 +(((
1320 1320  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1321 1321  )))
1354 +)))
1355 +)))
1322 1322  
1323 1323  
1324 1324  [[image:image-20220602175818-12.png]]
... ... @@ -1381,7 +1381,6 @@
1381 1381  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1382 1382  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1383 1383  
1384 -
1385 1385  = 9.Packing Info =
1386 1386  
1387 1387  
... ... @@ -1398,7 +1398,6 @@
1398 1398  * Package Size / pcs : 14.5 x 8 x 5 cm
1399 1399  * Weight / pcs : 170g
1400 1400  
1401 -
1402 1402  = 10. FCC Caution for RS485LN-US915 =
1403 1403  
1404 1404  (((