Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -103,7 +103,6 @@ 103 103 * Support Modbus protocol 104 104 * Support Interrupt uplink (Since hardware version v1.2) 105 105 106 - 107 107 == 1.4 Applications == 108 108 109 109 * Smart Buildings & Home Automation ... ... @@ -113,7 +113,6 @@ 113 113 * Smart Cities 114 114 * Smart Factory 115 115 116 - 117 117 == 1.5 Firmware Change log == 118 118 119 119 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -235,11 +235,15 @@ 235 235 236 236 ((( 237 237 ((( 236 +((( 238 238 There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 239 239 ))) 239 +))) 240 240 241 241 ((( 242 +((( 242 242 (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 244 +))) 243 243 244 244 245 245 ))) ... ... @@ -308,7 +308,6 @@ 308 308 ))) 309 309 310 310 311 - 312 312 === 3.3.2 Configure sensors === 313 313 314 314 ((( ... ... @@ -328,7 +328,6 @@ 328 328 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 329 329 330 330 331 - 332 332 === 3.3.3 Configure read commands for each sampling === 333 333 334 334 ((( ... ... @@ -1106,29 +1106,29 @@ 1106 1106 ))) 1107 1107 1108 1108 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1109 -|=(% style="width: 1 61px;" %)(((1110 -**Command example :**1111 -)))|=(% style="width: 337px;" %)(((1109 +|=(% style="width: 100px;" %)((( 1110 +**Command example** 1111 +)))|=(% style="width: 400px;" %)((( 1112 1112 **Function** 1113 1113 ))) 1114 -|(% style="width:1 61px" %)(((1114 +|(% style="width:100px" %)((( 1115 1115 AT+RXMODE=1,10 1116 -)))|(% style="width: 337px" %)(((1116 +)))|(% style="width:400px" %)((( 1117 1117 Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1118 1118 ))) 1119 -|(% style="width:1 61px" %)(((1119 +|(% style="width:100px" %)((( 1120 1120 AT+RXMODE=2,500 1121 -)))|(% style="width: 337px" %)(((1121 +)))|(% style="width:400px" %)((( 1122 1122 Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1123 1123 ))) 1124 -|(% style="width:1 61px" %)(((1124 +|(% style="width:100px" %)((( 1125 1125 AT+RXMODE=0,0 1126 -)))|(% style="width: 337px" %)(((1126 +)))|(% style="width:400px" %)((( 1127 1127 Disable listening mode. This is the default settings. 1128 1128 ))) 1129 -|(% style="width:1 61px" %)(((1129 +|(% style="width:100px" %)((( 1130 1130 1131 -)))|(% style="width: 337px" %)(((1131 +)))|(% style="width:400px" %)((( 1132 1132 A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1133 1133 ))) 1134 1134 ... ... @@ -1184,23 +1184,22 @@ 1184 1184 == 3.7 Buttons == 1185 1185 1186 1186 1187 -(% border="1" style="background-color:#f7faff; width: 500px" %)1188 -|=**Button**|=(% style="width: 1420px;" %)**Feature**1189 -|**ACT**|(% style="width: 1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**1190 -|**RST**|(% style="width: 1420px" %)Reboot RS4851191 -|**PRO**|(% style="width: 1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]1187 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:400px" %) 1188 +|=(% style="width: 50px;" %)**Button**|=(% style="width: 350px;" %)**Feature** 1189 +|(% style="width:50px" %)**ACT**|(% style="width:350px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 1190 +|(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485 1191 +|(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1192 1192 1193 1193 1194 - 1195 1195 == 3.8 LEDs == 1196 1196 1197 -(% border="1" style="background-color:#f7faff; width:500px" %) 1198 -|=**LEDs**|=**Feature** 1196 + 1197 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1198 +|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature** 1199 1199 |**PWR**|Always on if there is power 1200 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink 1200 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1201 1201 1202 1202 1203 - 1204 1204 = 4. Case Study = 1205 1205 1206 1206 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -1210,19 +1210,26 @@ 1210 1210 1211 1211 == 5.1 Access AT Command == 1212 1212 1212 +((( 1213 1213 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1214 +))) 1214 1214 1215 1215 [[image:1654162355560-817.png]] 1216 1216 1217 1217 1219 +((( 1218 1218 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1221 +))) 1219 1219 1220 1220 [[image:1654162368066-342.png]] 1221 1221 1222 1222 1226 +((( 1223 1223 More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1228 +))) 1224 1224 1225 1225 1231 + 1226 1226 == 5.2 Common AT Command Sequence == 1227 1227 1228 1228 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === ... ... @@ -1296,13 +1296,23 @@ 1296 1296 1297 1297 == 6.1 How to upgrade the image? == 1298 1298 1305 +((( 1299 1299 The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to: 1307 +))) 1300 1300 1301 -* Support new features 1302 -* For bug fix 1303 -* Change LoRaWAN bands. 1309 +* ((( 1310 +Support new features 1311 +))) 1312 +* ((( 1313 +For bug fix 1314 +))) 1315 +* ((( 1316 +Change LoRaWAN bands. 1317 +))) 1304 1304 1319 +((( 1305 1305 Below shows the hardware connection for how to upload an image to RS485-LN: 1321 +))) 1306 1306 1307 1307 [[image:1654162535040-878.png]] 1308 1308 ... ... @@ -1313,8 +1313,10 @@ 1313 1313 **Step3: **Open flashloader; choose the correct COM port to update. 1314 1314 1315 1315 ((( 1332 +((( 1316 1316 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 1317 1317 ))) 1335 +))) 1318 1318 1319 1319 1320 1320 [[image:image-20220602175818-12.png]] ... ... @@ -1377,7 +1377,6 @@ 1377 1377 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1378 1378 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1379 1379 1380 - 1381 1381 = 9.Packing Info = 1382 1382 1383 1383 ... ... @@ -1394,7 +1394,6 @@ 1394 1394 * Package Size / pcs : 14.5 x 8 x 5 cm 1395 1395 * Weight / pcs : 170g 1396 1396 1397 - 1398 1398 = 10. FCC Caution for RS485LN-US915 = 1399 1399 1400 1400 (((