From version < 58.23 >
edited by Xiaoling
on 2022/06/06 11:26
To version < 58.50 >
edited by Xiaoling
on 2022/06/06 13:46
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -103,7 +103,6 @@
103 103  * Support Modbus protocol
104 104  * Support Interrupt uplink (Since hardware version v1.2)
105 105  
106 -
107 107  == 1.4 Applications ==
108 108  
109 109  * Smart Buildings & Home Automation
... ... @@ -113,7 +113,6 @@
113 113  * Smart Cities
114 114  * Smart Factory
115 115  
116 -
117 117  == 1.5 Firmware Change log ==
118 118  
119 119  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -235,11 +235,15 @@
235 235  
236 236  (((
237 237  (((
236 +(((
238 238  There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
239 239  )))
239 +)))
240 240  
241 241  (((
242 +(((
242 242  (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1
244 +)))
243 243  
244 244  
245 245  )))
... ... @@ -308,7 +308,6 @@
308 308  )))
309 309  
310 310  
311 -
312 312  === 3.3.2 Configure sensors ===
313 313  
314 314  (((
... ... @@ -328,7 +328,6 @@
328 328  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
329 329  
330 330  
331 -
332 332  === 3.3.3 Configure read commands for each sampling ===
333 333  
334 334  (((
... ... @@ -1106,29 +1106,29 @@
1106 1106  )))
1107 1107  
1108 1108  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
1109 -|=(% style="width: 161px;" %)(((
1110 -**Command example:**
1111 -)))|=(% style="width: 337px;" %)(((
1109 +|=(% style="width: 100px;" %)(((
1110 +**Command example**
1111 +)))|=(% style="width: 400px;" %)(((
1112 1112  **Function**
1113 1113  )))
1114 -|(% style="width:161px" %)(((
1114 +|(% style="width:100px" %)(((
1115 1115  AT+RXMODE=1,10
1116 -)))|(% style="width:337px" %)(((
1116 +)))|(% style="width:400px" %)(((
1117 1117  Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
1118 1118  )))
1119 -|(% style="width:161px" %)(((
1119 +|(% style="width:100px" %)(((
1120 1120  AT+RXMODE=2,500
1121 -)))|(% style="width:337px" %)(((
1121 +)))|(% style="width:400px" %)(((
1122 1122  Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
1123 1123  )))
1124 -|(% style="width:161px" %)(((
1124 +|(% style="width:100px" %)(((
1125 1125  AT+RXMODE=0,0
1126 -)))|(% style="width:337px" %)(((
1126 +)))|(% style="width:400px" %)(((
1127 1127  Disable listening mode. This is the default settings.
1128 1128  )))
1129 -|(% style="width:161px" %)(((
1129 +|(% style="width:100px" %)(((
1130 1130  
1131 -)))|(% style="width:337px" %)(((
1131 +)))|(% style="width:400px" %)(((
1132 1132  A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 | cc)
1133 1133  )))
1134 1134  
... ... @@ -1177,28 +1177,31 @@
1177 1177  )))
1178 1178  
1179 1179  (((
1180 +(((
1180 1180  (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
1181 1181  )))
1183 +)))
1182 1182  
1183 1183  
1184 1184  == 3.7 Buttons ==
1185 1185  
1186 1186  
1187 -(% border="1" style="background-color:#f7faff; width:500px" %)
1188 -|=**Button**|=(% style="width: 1420px;" %)**Feature**
1189 -|**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1190 -|**RST**|(% style="width:1420px" %)Reboot RS485
1191 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1189 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:400px" %)
1190 +|=(% style="width: 50px;" %)**Button**|=(% style="width: 350px;" %)**Feature**
1191 +|(% style="width:50px" %)**ACT**|(% style="width:350px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1192 +|(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485
1193 +|(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1192 1192  
1193 1193  
1194 -
1195 1195  == 3.8 LEDs ==
1196 1196  
1197 -(% border="1" style="background-color:#f7faff; width:500px" %)
1198 -|=**LEDs**|=**Feature**
1198 +
1199 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1200 +|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature**
1199 1199  |**PWR**|Always on if there is power
1200 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1202 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1201 1201  
1204 +
1202 1202  = 4. Case Study =
1203 1203  
1204 1204  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1208,19 +1208,26 @@
1208 1208  
1209 1209  == 5.1 Access AT Command ==
1210 1210  
1214 +(((
1211 1211  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1216 +)))
1212 1212  
1213 1213  [[image:1654162355560-817.png]]
1214 1214  
1215 1215  
1221 +(((
1216 1216  In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1223 +)))
1217 1217  
1218 1218  [[image:1654162368066-342.png]]
1219 1219  
1220 1220  
1228 +(((
1221 1221  More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1230 +)))
1222 1222  
1223 1223  
1233 +
1224 1224  == 5.2 Common AT Command Sequence ==
1225 1225  
1226 1226  === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
... ... @@ -1294,13 +1294,23 @@
1294 1294  
1295 1295  == 6.1 How to upgrade the image? ==
1296 1296  
1307 +(((
1297 1297  The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to:
1309 +)))
1298 1298  
1299 -* Support new features
1300 -* For bug fix
1301 -* Change LoRaWAN bands.
1311 +* (((
1312 +Support new features
1313 +)))
1314 +* (((
1315 +For bug fix
1316 +)))
1317 +* (((
1318 +Change LoRaWAN bands.
1319 +)))
1302 1302  
1321 +(((
1303 1303  Below shows the hardware connection for how to upload an image to RS485-LN:
1323 +)))
1304 1304  
1305 1305  [[image:1654162535040-878.png]]
1306 1306  
... ... @@ -1311,8 +1311,10 @@
1311 1311  **Step3: **Open flashloader; choose the correct COM port to update.
1312 1312  
1313 1313  (((
1334 +(((
1314 1314  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1315 1315  )))
1337 +)))
1316 1316  
1317 1317  
1318 1318  [[image:image-20220602175818-12.png]]
... ... @@ -1375,7 +1375,6 @@
1375 1375  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1376 1376  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1377 1377  
1378 -
1379 1379  = 9.Packing Info =
1380 1380  
1381 1381  
... ... @@ -1392,7 +1392,6 @@
1392 1392  * Package Size / pcs : 14.5 x 8 x 5 cm
1393 1393  * Weight / pcs : 170g
1394 1394  
1395 -
1396 1396  = 10. FCC Caution for RS485LN-US915 =
1397 1397  
1398 1398  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0