From version < 58.22 >
edited by Xiaoling
on 2022/06/06 11:25
To version < 58.37 >
edited by Xiaoling
on 2022/06/06 11:53
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -103,7 +103,6 @@
103 103  * Support Modbus protocol
104 104  * Support Interrupt uplink (Since hardware version v1.2)
105 105  
106 -
107 107  == 1.4 Applications ==
108 108  
109 109  * Smart Buildings & Home Automation
... ... @@ -113,7 +113,6 @@
113 113  * Smart Cities
114 114  * Smart Factory
115 115  
116 -
117 117  == 1.5 Firmware Change log ==
118 118  
119 119  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -307,8 +307,6 @@
307 307  )))
308 308  )))
309 309  
310 -
311 -
312 312  === 3.3.2 Configure sensors ===
313 313  
314 314  (((
... ... @@ -327,8 +327,6 @@
327 327  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
328 328  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
329 329  
330 -
331 -
332 332  === 3.3.3 Configure read commands for each sampling ===
333 333  
334 334  (((
... ... @@ -1184,19 +1184,21 @@
1184 1184  == 3.7 Buttons ==
1185 1185  
1186 1186  
1187 -(% border="1" style="background-color:#f7faff; width:500px" %)
1188 -|=**Button**|=(% style="width: 1420px;" %)**Feature**
1189 -|**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1190 -|**RST**|(% style="width:1420px" %)Reboot RS485
1191 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1181 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1182 +|=(% style="width: 30px;" %)**Button**|=(% style="width: 355px;" %)**Feature**
1183 +|(% style="width:30px" %)**ACT**|(% style="width:355px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1184 +|(% style="width:30px" %)**RST**|(% style="width:355px" %)Reboot RS485
1185 +|(% style="width:30px" %)**PRO**|(% style="width:355px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1192 1192  
1193 1193  == 3.8 LEDs ==
1194 1194  
1195 -(% border="1" style="background-color:#f7faff; width:500px" %)
1196 -|=**LEDs**|=**Feature**
1189 +
1190 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1191 +|=(% style="width: 30px;" %)**LEDs**|=(% style="width: 400px;" %)**Feature**
1197 1197  |**PWR**|Always on if there is power
1198 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1193 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1199 1199  
1195 +
1200 1200  = 4. Case Study =
1201 1201  
1202 1202  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1206,19 +1206,26 @@
1206 1206  
1207 1207  == 5.1 Access AT Command ==
1208 1208  
1205 +(((
1209 1209  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1207 +)))
1210 1210  
1211 1211  [[image:1654162355560-817.png]]
1212 1212  
1213 1213  
1212 +(((
1214 1214  In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1214 +)))
1215 1215  
1216 1216  [[image:1654162368066-342.png]]
1217 1217  
1218 1218  
1219 +(((
1219 1219  More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1221 +)))
1220 1220  
1221 1221  
1224 +
1222 1222  == 5.2 Common AT Command Sequence ==
1223 1223  
1224 1224  === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
... ... @@ -1292,13 +1292,23 @@
1292 1292  
1293 1293  == 6.1 How to upgrade the image? ==
1294 1294  
1298 +(((
1295 1295  The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to:
1300 +)))
1296 1296  
1297 -* Support new features
1298 -* For bug fix
1299 -* Change LoRaWAN bands.
1302 +* (((
1303 +Support new features
1304 +)))
1305 +* (((
1306 +For bug fix
1307 +)))
1308 +* (((
1309 +Change LoRaWAN bands.
1310 +)))
1300 1300  
1312 +(((
1301 1301  Below shows the hardware connection for how to upload an image to RS485-LN:
1314 +)))
1302 1302  
1303 1303  [[image:1654162535040-878.png]]
1304 1304  
... ... @@ -1309,8 +1309,10 @@
1309 1309  **Step3: **Open flashloader; choose the correct COM port to update.
1310 1310  
1311 1311  (((
1325 +(((
1312 1312  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1313 1313  )))
1328 +)))
1314 1314  
1315 1315  
1316 1316  [[image:image-20220602175818-12.png]]
... ... @@ -1373,7 +1373,6 @@
1373 1373  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1374 1374  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1375 1375  
1376 -
1377 1377  = 9.Packing Info =
1378 1378  
1379 1379  
... ... @@ -1390,7 +1390,6 @@
1390 1390  * Package Size / pcs : 14.5 x 8 x 5 cm
1391 1391  * Weight / pcs : 170g
1392 1392  
1393 -
1394 1394  = 10. FCC Caution for RS485LN-US915 =
1395 1395  
1396 1396  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0