From version < 58.22 >
edited by Xiaoling
on 2022/06/06 11:25
To version < 58.29 >
edited by Xiaoling
on 2022/06/06 11:42
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -103,7 +103,6 @@
103 103  * Support Modbus protocol
104 104  * Support Interrupt uplink (Since hardware version v1.2)
105 105  
106 -
107 107  == 1.4 Applications ==
108 108  
109 109  * Smart Buildings & Home Automation
... ... @@ -113,7 +113,6 @@
113 113  * Smart Cities
114 114  * Smart Factory
115 115  
116 -
117 117  == 1.5 Firmware Change log ==
118 118  
119 119  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -307,8 +307,6 @@
307 307  )))
308 308  )))
309 309  
310 -
311 -
312 312  === 3.3.2 Configure sensors ===
313 313  
314 314  (((
... ... @@ -327,8 +327,6 @@
327 327  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
328 328  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
329 329  
330 -
331 -
332 332  === 3.3.3 Configure read commands for each sampling ===
333 333  
334 334  (((
... ... @@ -1184,19 +1184,23 @@
1184 1184  == 3.7 Buttons ==
1185 1185  
1186 1186  
1187 -(% border="1" style="background-color:#f7faff; width:500px" %)
1188 -|=**Button**|=(% style="width: 1420px;" %)**Feature**
1189 -|**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1190 -|**RST**|(% style="width:1420px" %)Reboot RS485
1191 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1181 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1182 +|=(% style="width: 30px;" %)**Button**|=(% style="width: 355px;" %)**Feature**
1183 +|=(% style="width: 30px;" %)**ACT**|(% style="width:355px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1184 +|=(% style="width: 30px;" %)**RST**|(% style="width:355px" %)Reboot RS485
1185 +|=(% style="width: 30px;" %)**PRO**|(% style="width:355px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1192 1192  
1187 +
1188 +
1193 1193  == 3.8 LEDs ==
1194 1194  
1195 -(% border="1" style="background-color:#f7faff; width:500px" %)
1196 -|=**LEDs**|=**Feature**
1197 -|**PWR**|Always on if there is power
1198 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1191 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)
1192 +|=(% style="width: 30px;" %)**LEDs**|=(% style="width: 400px;" %)**Feature**
1193 +|(% style="width:30px" %)**PWR**|=(% style="width: 400px;" %)Always on if there is power
1194 +|(% style="width:30px" %)**SYS**|=(% style="width: 400px;" %)After device is powered on, the SYS will (% style="color:green" %)fast blink in GREEN (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)on GREEN for 5 seconds(%%). SYS will (% style="color:green" %)blink Blue(%%) on every upload and (% style="color:green" %)blink Green(%%) once receive a downlink message.
1199 1199  
1196 +
1197 +
1200 1200  = 4. Case Study =
1201 1201  
1202 1202  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1206,19 +1206,26 @@
1206 1206  
1207 1207  == 5.1 Access AT Command ==
1208 1208  
1207 +(((
1209 1209  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1209 +)))
1210 1210  
1211 1211  [[image:1654162355560-817.png]]
1212 1212  
1213 1213  
1214 +(((
1214 1214  In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1216 +)))
1215 1215  
1216 1216  [[image:1654162368066-342.png]]
1217 1217  
1218 1218  
1221 +(((
1219 1219  More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1223 +)))
1220 1220  
1221 1221  
1226 +
1222 1222  == 5.2 Common AT Command Sequence ==
1223 1223  
1224 1224  === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
... ... @@ -1373,7 +1373,6 @@
1373 1373  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1374 1374  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1375 1375  
1376 -
1377 1377  = 9.Packing Info =
1378 1378  
1379 1379  
... ... @@ -1390,7 +1390,6 @@
1390 1390  * Package Size / pcs : 14.5 x 8 x 5 cm
1391 1391  * Weight / pcs : 170g
1392 1392  
1393 -
1394 1394  = 10. FCC Caution for RS485LN-US915 =
1395 1395  
1396 1396  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved