... ... @@ -1184,19 +1184,23 @@
1184 1184  == 3.7 Buttons ==
1185 1185  
1186 1186  
1187 -(% border="1" style="background-color:#f7faff; width:500px" %)
1187 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)
1188 1188  |=**Button**|=(% style="width: 1420px;" %)**Feature**
1189 1189  |**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1190 1190  |**RST**|(% style="width:1420px" %)Reboot RS485
1191 1191  |**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1192 1192  
1193 +
1194 +
1193 1193  == 3.8 LEDs ==
1194 1194  
1195 -(% border="1" style="background-color:#f7faff; width:500px" %)
1197 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)
1196 1196  |=**LEDs**|=**Feature**
1197 1197  |**PWR**|Always on if there is power
1198 1198  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1199 1199  
1202 +
1203 +
1200 1200  = 4. Case Study =
1201 1201  
1202 1202  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1206,12 +1206,16 @@
1206 1206  
1207 1207  == 5.1 Access AT Command ==
1208 1208  
1213 +(((
1209 1209  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1215 +)))
1210 1210  
1211 1211  [[image:1654162355560-817.png]]
1212 1212  
1213 1213  
1220 +(((
1214 1214  In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1222 +)))
1215 1215  
1216 1216  [[image:1654162368066-342.png]]
1217 1217  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved