... ... @@ -1097,88 +1097,37 @@ 1097 1097 1098 1098 [[image:image-20220602171200-8.png||height="567" width="1007"]] 1099 1099 1100 -((( 1101 1101 To enable the listening mode, use can run the command AT+RXMODE. 1102 -))) 1103 1103 1104 -((( 1105 - 1106 -))) 1107 1107 1108 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1109 -|=(% style="width: 161px;" %)((( 1110 -**Command example:** 1111 -)))|=(% style="width: 337px;" %)((( 1112 -**Function** 1113 -))) 1114 -|(% style="width:161px" %)((( 1115 -AT+RXMODE=1,10 1116 -)))|(% style="width:337px" %)((( 1117 -Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1118 -))) 1119 -|(% style="width:161px" %)((( 1120 -AT+RXMODE=2,500 1121 -)))|(% style="width:337px" %)((( 1122 -Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1123 -))) 1124 -|(% style="width:161px" %)((( 1125 -AT+RXMODE=0,0 1126 -)))|(% style="width:337px" %)((( 1127 -Disable listening mode. This is the default settings. 1128 -))) 1129 -|(% style="width:161px" %)((( 1130 - 1131 -)))|(% style="width:337px" %)((( 1132 -A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1133 -))) 1103 +(% border="1" style="background-color:#ffffcc; width:500px" %) 1104 +|=(% style="width: 161px;" %)**Command example:**|=(% style="width: 337px;" %)**Function** 1105 +|(% style="width:161px" %)AT+RXMODE=1,10 |(% style="width:337px" %)Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1106 +|(% style="width:161px" %)AT+RXMODE=2,500|(% style="width:337px" %)Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1107 +|(% style="width:161px" %)AT+RXMODE=0,0|(% style="width:337px" %)Disable listening mode. This is the default settings. 1108 +|(% style="width:161px" %) |(% style="width:337px" %)A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 ~| cc) 1134 1134 1135 -((( 1136 1136 **Downlink Command:** 1137 -))) 1138 1138 1139 -((( 1140 1140 **0xA6 aa bb cc ** same as AT+RXMODE=aa,(bb<<8 | cc) 1141 -))) 1142 1142 1143 -((( 1144 - 1145 -))) 1146 1146 1147 -((( 1148 1148 **Example**: 1149 -))) 1150 1150 1151 -((( 1152 1152 The RS485-LN is set to AT+RXMODE=2,1000 1153 -))) 1154 1154 1155 -((( 1156 1156 There is a two Modbus commands in the RS485 network as below: 1157 -))) 1158 1158 1159 -((( 1160 1160 The Modbus master send a command: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b 1161 -))) 1162 1162 1163 -((( 1164 1164 And Modbus slave reply with: (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 1165 -))) 1166 1166 1167 -((( 1168 1168 RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 1169 -))) 1170 1170 1171 -((( 1172 1172 [[image:image-20220602171200-9.png]] 1173 -))) 1174 1174 1175 -((( 1176 - 1177 -))) 1178 1178 1179 -((( 1180 1180 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1181 -))) 1182 1182 1183 1183 1184 1184 == 3.7 Buttons ==