Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -509,14 +509,27 @@ 509 509 510 510 == 3.5 Configure RS485-BL via AT or Downlink == 511 511 512 +((( 512 512 User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands 514 +))) 513 513 516 +((( 514 514 There are two kinds of Commands: 518 +))) 515 515 516 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 520 +* ((( 521 +(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 522 +))) 517 517 518 -* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN. User can see these commands below: 524 +* ((( 525 +(% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN. User can see these commands below: 526 +))) 519 519 528 +((( 529 + 530 +))) 531 + 532 + 520 520 === 3.5.1 Common Commands === 521 521 522 522 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -535,142 +535,282 @@ 535 535 536 536 537 537 551 + 538 538 ==== **RS485 Debug Command** ==== 539 539 554 +((( 540 540 This command is used to configure the RS485 devices; they won’t be used during sampling. 556 +))) 541 541 542 -* **AT Command** 558 +* ((( 559 +**AT Command** 560 +))) 543 543 544 544 (% class="box infomessage" %) 545 545 ((( 564 +((( 546 546 **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 547 547 ))) 567 +))) 548 548 569 +((( 549 549 m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 571 +))) 550 550 551 -* **Downlink Payload** 573 +* ((( 574 +**Downlink Payload** 575 +))) 552 552 577 +((( 553 553 Format: A8 MM NN XX XX XX XX YY 579 +))) 554 554 581 +((( 555 555 Where: 583 +))) 556 556 557 -* MM: 1: add CRC-16/MODBUS ; 0: no CRC 558 -* NN: The length of RS485 command 559 -* XX XX XX XX: RS485 command total NN bytes 560 -* YY: How many bytes will be uplink from the return of this RS485 command, 561 -** if YY=0, RS485-LN will execute the downlink command without uplink; 562 -** if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200 563 -** if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200. 585 +* ((( 586 +MM: 1: add CRC-16/MODBUS ; 0: no CRC 587 +))) 588 +* ((( 589 +NN: The length of RS485 command 590 +))) 591 +* ((( 592 +XX XX XX XX: RS485 command total NN bytes 593 +))) 594 +* ((( 595 +((( 596 +YY: How many bytes will be uplink from the return of this RS485 command, 597 +))) 564 564 599 +* ((( 600 +if YY=0, RS485-LN will execute the downlink command without uplink; 601 +))) 602 +* ((( 603 +if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200 604 +))) 605 +* ((( 606 +if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200. 607 +))) 608 +))) 609 + 610 +((( 565 565 **Example 1** ~-~-> Configure without ask for uplink (YY=0) 612 +))) 566 566 614 +((( 567 567 To connect a Modbus Alarm with below commands. 616 +))) 568 568 569 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 618 +* ((( 619 +The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 620 +))) 570 570 571 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 622 +* ((( 623 +The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 624 +))) 572 572 626 +((( 573 573 So if user want to use downlink command to control to RS485 Alarm, he can use: 628 +))) 574 574 630 +((( 575 575 (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 632 +))) 576 576 634 +((( 577 577 (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 636 +))) 578 578 638 +((( 579 579 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 640 +))) 580 580 642 +((( 643 + 644 +))) 581 581 646 +((( 582 582 **Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 648 +))) 583 583 650 +((( 584 584 User in IoT server send a downlink command: (% style="color:#4f81bd" %)**A8 01 06 0A 08 00 04 00 01 YY** 652 +))) 585 585 654 +((( 655 + 656 +))) 586 586 658 +((( 587 587 RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: 660 +))) 588 588 662 +((( 589 589 **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 664 +))) 590 590 666 +((( 591 591 [[image:1654159460680-153.png]] 668 +))) 592 592 593 593 594 594 672 + 595 595 ==== **Set Payload version** ==== 596 596 675 +((( 597 597 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 677 +))) 598 598 599 -* **AT Command:** 679 +* ((( 680 +**AT Command:** 681 +))) 600 600 601 601 (% class="box infomessage" %) 602 602 ((( 685 +((( 603 603 **AT+PAYVER: Set PAYVER field = 1** 604 604 ))) 688 +))) 605 605 606 -* **Downlink Payload:** 690 +* ((( 691 +**Downlink Payload:** 692 +))) 607 607 694 +((( 608 608 **0xAE 01** ~-~-> Set PAYVER field = 0x01 696 +))) 609 609 698 +((( 610 610 **0xAE 0F** ~-~-> Set PAYVER field = 0x0F 700 +))) 611 611 612 612 613 613 704 + 614 614 ==== **Set RS485 Sampling Commands** ==== 615 615 707 +((( 616 616 AT+COMMANDx or AT+DATACUTx 709 +))) 617 617 711 +((( 618 618 These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 713 +))) 619 619 715 +((( 716 + 717 +))) 620 620 621 -* **AT Command:** 719 +* ((( 720 +**AT Command:** 721 +))) 622 622 623 623 (% class="box infomessage" %) 624 624 ((( 725 +((( 625 625 **AT+COMMANDx: Configure RS485 read command to sensor.** 626 626 ))) 728 +))) 627 627 628 628 (% class="box infomessage" %) 629 629 ((( 732 +((( 630 630 **AT+DATACUTx: Configure how to handle return from RS485 devices.** 631 631 ))) 735 +))) 632 632 737 +((( 738 + 739 +))) 633 633 634 -* **Downlink Payload:** 741 +* ((( 742 +**Downlink Payload:** 743 +))) 635 635 745 +((( 636 636 **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 747 +))) 637 637 749 +((( 638 638 (% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 751 +))) 639 639 753 +((( 640 640 Format: AF MM NN LL XX XX XX XX YY 755 +))) 641 641 757 +((( 642 642 Where: 759 +))) 643 643 644 -* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 645 -* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 646 -* LL: The length of AT+COMMAND or AT+DATACUT command 647 -* XX XX XX XX: AT+COMMAND or AT+DATACUT command 648 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 761 +* ((( 762 +MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 763 +))) 764 +* ((( 765 +NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 766 +))) 767 +* ((( 768 +LL: The length of AT+COMMAND or AT+DATACUT command 769 +))) 770 +* ((( 771 +XX XX XX XX: AT+COMMAND or AT+DATACUT command 772 +))) 773 +* ((( 774 +YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 775 +))) 649 649 777 +((( 650 650 **Example:** 779 +))) 651 651 781 +((( 652 652 (% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1 783 +))) 653 653 785 +((( 654 654 (% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10** 787 +))) 655 655 789 +((( 656 656 (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10** 791 +))) 657 657 658 658 659 659 795 + 660 660 ==== **Fast command to handle MODBUS device** ==== 661 661 798 +((( 662 662 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 800 +))) 663 663 802 +((( 664 664 This command is valid since v1.3 firmware version 804 +))) 665 665 806 +((( 666 666 AT+MBFUN can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 808 +))) 667 667 810 +((( 811 + 812 +))) 668 668 814 +((( 669 669 **Example:** 816 +))) 670 670 671 -* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 672 -* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 673 -* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 818 +* ((( 819 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 820 +))) 821 +* ((( 822 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 823 +))) 824 +* ((( 825 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 826 +))) 674 674 675 675 [[image:image-20220602165351-6.png]] 676 676 ... ... @@ -678,63 +678,110 @@ 678 678 679 679 680 680 834 + 681 681 ==== **RS485 command timeout** ==== 682 682 837 +((( 683 683 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. 839 +))) 684 684 841 +((( 685 685 Default value: 0, range: 0 ~~ 65 seconds 843 +))) 686 686 687 -* **AT Command:** 845 +* ((( 846 +**AT Command:** 847 +))) 688 688 689 689 (% class="box infomessage" %) 690 690 ((( 851 +((( 691 691 **AT+CMDDLaa=hex(bb cc)*1000** 692 692 ))) 854 +))) 693 693 856 +((( 694 694 **Example:** 858 +))) 695 695 860 +((( 696 696 **AT+CMDDL1=1000** to send the open time to 1000ms 862 +))) 697 697 864 +((( 865 + 866 +))) 698 698 699 -* **Downlink Payload:** 868 +* ((( 869 +**Downlink Payload:** 870 +))) 700 700 872 +((( 701 701 **0x AA aa bb cc** 874 +))) 702 702 876 +((( 703 703 Same as: AT+CMDDLaa=hex(bb cc)*1000 878 +))) 704 704 880 +((( 705 705 **Example:** 882 +))) 706 706 884 +((( 707 707 0xAA 01 00 01 ~-~-> Same as **AT+CMDDL1=1000 ms** 886 +))) 708 708 709 709 710 710 890 + 711 711 ==== **Uplink payload mode** ==== 712 712 893 +((( 713 713 Define to use one uplink or multiple uplinks for the sampling. 895 +))) 714 714 897 +((( 715 715 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 899 +))) 716 716 717 -* **AT Command:** 901 +* ((( 902 +**AT Command:** 903 +))) 718 718 719 719 (% class="box infomessage" %) 720 720 ((( 907 +((( 721 721 **AT+DATAUP=0** 722 722 ))) 910 +))) 723 723 724 724 (% class="box infomessage" %) 725 725 ((( 914 +((( 726 726 **AT+DATAUP=1** 727 727 ))) 917 +))) 728 728 919 +((( 920 + 921 +))) 729 729 730 -* **Downlink Payload:** 923 +* ((( 924 +**Downlink Payload:** 925 +))) 731 731 927 +((( 732 732 **0xAD 00** **~-~->** Same as AT+DATAUP=0 929 +))) 733 733 931 +((( 734 734 **0xAD 01** **~-~->** Same as AT+DATAUP=1 933 +))) 735 735 736 736 737 737 937 + 738 738 ==== **Manually trigger an Uplink** ==== 739 739 740 740 Ask device to send an uplink immediately. ... ... @@ -750,6 +750,7 @@ 750 750 751 751 752 752 953 + 753 753 ==== **Clear RS485 Command** ==== 754 754 755 755 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. ... ... @@ -774,6 +774,7 @@ 774 774 775 775 776 776 978 + 777 777 ==== **Set Serial Communication Parameters** ==== 778 778 779 779 Set the Rs485 serial communication parameters: