<
From version < 58.2 >
edited by Xiaoling
on 2022/06/06 11:09
To version < 57.35 >
edited by Xiaoling
on 2022/06/06 09:32
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,5 @@
1 1  (% style="text-align:center" %)
2 -[[image:1653266934636-343.png||height="385" width="385"]]
2 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653266934636-343.png?width=385&height=385&rev=1.1||alt="1653266934636-343.png" height="385" width="385"]]
3 3  
4 4  
5 5  
... ... @@ -10,7 +10,59 @@
10 10  
11 11  **Table of Contents:**
12 12  
13 -{{toc/}}
13 +* [[1.Introduction>>path:#H1.Introduction]]
14 +** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>path:#H1.1A0WhatisRS485-LNRS485toLoRaWANConverter]]
15 +** [[1.2 Specifications>>path:#H1.2A0Specifications]]
16 +** [[1.3 Features>>path:#H1.3Features]]
17 +** [[1.4 Applications>>path:#H1.4A0Applications]]
18 +** [[1.5 Firmware Change log>>path:#H1.5A0FirmwareChangelog]]
19 +** [[1.6 Hardware Change log>>path:#H1.6HardwareChangelog]]
20 +* [[2. Power ON Device>>path:#H2.PowerONDevice]]
21 +* [[3. Operation Mode>>path:#H3.A0OperationMode]]
22 +** [[3.1 How it works?>>path:#H3.1Howitworks3F]]
23 +** [[3.2 Example to join LoRaWAN network>>path:#H3.2ExampletojoinLoRaWANnetwork]]
24 +** [[3.3 Configure Commands to read data>>path:#H3.3ConfigureCommandstoreaddata]]
25 +*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>path:#H3.3.1onfigureUARTsettingsforRS485orTTLcommunication]]
26 +*** [[3.3.2 Configure sensors>>path:#H3.3.2Configuresensors]]
27 +*** [[3.3.3 Configure read commands for each sampling>>path:#H3.3.3Configurereadcommandsforeachsampling]]
28 +*** [[3.3.4 Compose the uplink payload>>path:#H3.3.4Composetheuplinkpayload]]
29 +*** [[3.3.5 Uplink on demand>>path:#H3.3.5Uplinkondemand]]
30 +*** [[3.3.6 Uplink on Interrupt>>path:#H3.3.6UplinkonInterrupt]]
31 +** [[3.4 Uplink Payload>>path:#H3.4UplinkPayload]]
32 +** [[3.5 Configure RS485-BL via AT or Downlink>>path:#H3.5ConfigureRS485-BLviaATorDownlink]]
33 +*** [[3.5.1 Common Commands>>path:#H3.5.1CommonCommands]]
34 +*** [[3.5.2 Sensor related commands>>path:#H3.5.2Sensorrelatedcommands]]
35 +*** [[3.5.3 Sensor related commands>>path:#H3.5.3A0Sensorrelatedcommands]]
36 +**** [[RS485 Debug Command>>path:#HRS485DebugCommand]]
37 +**** [[Set Payload version>>path:#HSetPayloadversion]]
38 +**** [[Set RS485 Sampling Commands>>path:#HSetRS485SamplingCommands]]
39 +**** [[Fast command to handle MODBUS device>>path:#HFastcommandtohandleMODBUSdevice]]
40 +**** [[RS485 command timeout>>path:#HRS485commandtimeout]]
41 +**** [[Uplink payload mode>>path:#HUplinkpayloadmode]]
42 +**** [[Manually trigger an Uplink>>path:#HManuallytriggeranUplink]]
43 +**** [[Clear RS485 Command>>path:#HClearRS485Command]]
44 +**** [[Set Serial Communication Parameters>>path:#HSetSerialCommunicationParameters]]
45 +** [[3.6 Listening mode for RS485 network>>path:#H3.6A0ListeningmodeforRS485network]]
46 +** [[3.7 Buttons>>path:#H3.7Buttons]]
47 +** [[3.8 LEDs>>path:#H3.8LEDs]]
48 +* [[4. Case Study>>path:#H4.CaseStudy]]
49 +* [[5. Use AT Command>>path:#H5.UseATCommand]]
50 +** [[5.1 Access AT Command>>path:#H5.1AccessATCommand]]
51 +** [[5.2 Common AT Command Sequence>>path:#H5.2CommonATCommandSequence]]
52 +*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>path:#H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829]]
53 +*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>path:#H5.5.2Single-channelABPmode28UsewithLG012FLG0229]]
54 +* [[6. FAQ>>path:#H6.FAQ]]
55 +** [[6.1 How to upgrade the image?>>path:#H6.1Howtoupgradetheimage3F]]
56 +** [[6.2 How to change the LoRa Frequency Bands/Region?>>path:#H6.2HowtochangetheLoRaFrequencyBands2FRegion3F]]
57 +** [[6.3 How many RS485-Slave can RS485-BL connects?>>path:#H6.3HowmanyRS485-SlavecanRS485-BLconnects3F]]
58 +** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>path:#H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F]]
59 +* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
60 +** [[7.1 Downlink doesn’t work, how to solve it?>>path:#H7.1Downlinkdoesn2019twork2Chowtosolveit3F]]
61 +** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>path:#H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F]]
62 +* [[8. Order Info>>path:#H8.OrderInfo]]
63 +* [[9.Packing Info>>path:#H9.PackingInfo]]
64 +* [[10. FCC Caution for RS485LN-US915>>path:#H10.FCCCautionforRS485LN-US915]]
65 +* [[11. Support>>path:#H11.Support]]
14 14  
15 15  
16 16  
... ... @@ -24,35 +24,25 @@
24 24  
25 25  (((
26 26  (((
27 -(((
28 28  The Dragino RS485-LN is a (% style="color:blue" %)**RS485 to LoRaWAN Converter**(%%). It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost.
29 29  )))
30 -)))
31 31  
32 32  (((
33 -(((
34 34  RS485-LN allows user to (% style="color:blue" %)**monitor / control RS485 devices**(%%) and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on.
35 35  )))
36 -)))
37 37  
38 38  (((
39 -(((
40 40  (% style="color:blue" %)**For data uplink**(%%), RS485-LN sends user-defined commands to RS485 devices and gets the return from the RS485 devices. RS485-LN will process these returns according to user-define rules to get the final payload and upload to LoRaWAN server.
41 41  )))
42 -)))
43 43  
44 44  (((
45 -(((
46 46  (% style="color:blue" %)**For data downlink**(%%), RS485-LN runs in LoRaWAN Class C. When there downlink commands from LoRaWAN server, RS485-LN will forward the commands from LoRaWAN server to RS485 devices.
47 -)))
48 48  
49 -(((
50 50  (% style="color:blue" %)**Demo Dashboard for RS485-LN**(%%) connect to two energy meters: [[https:~~/~~/app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a>>url:https://app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a]]
51 51  )))
52 52  )))
53 -)))
54 54  
55 -[[image:1653267211009-519.png||height="419" width="724"]]
97 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653267211009-519.png?width=724&height=419&rev=1.1||alt="1653267211009-519.png" height="419" width="724"]]
56 56  
57 57  
58 58  == 1.2 Specifications ==
... ... @@ -103,7 +103,6 @@
103 103  * Support Modbus protocol
104 104  * Support Interrupt uplink (Since hardware version v1.2)
105 105  
106 -
107 107  == 1.4 Applications ==
108 108  
109 109  * Smart Buildings & Home Automation
... ... @@ -113,7 +113,6 @@
113 113  * Smart Cities
114 114  * Smart Factory
115 115  
116 -
117 117  == 1.5 Firmware Change log ==
118 118  
119 119  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -123,13 +123,9 @@
123 123  
124 124  (((
125 125  (((
126 -(((
127 127  v1.2: Add External Interrupt Pin.
128 -)))
129 129  
130 -(((
131 131  v1.0: Release
132 -)))
133 133  
134 134  
135 135  )))
... ... @@ -147,7 +147,7 @@
147 147  Once there is power, the RS485-LN will be on.
148 148  )))
149 149  
150 -[[image:1653268091319-405.png]]
186 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268091319-405.png?rev=1.1||alt="1653268091319-405.png"]]
151 151  
152 152  
153 153  )))
... ... @@ -157,9 +157,7 @@
157 157  == 3.1 How it works? ==
158 158  
159 159  (((
160 -(((
161 161  The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA.
162 -)))
163 163  
164 164  
165 165  )))
... ... @@ -168,7 +168,7 @@
168 168  
169 169  Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
170 170  
171 -[[image:1653268155545-638.png||height="334" width="724"]]
205 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268155545-638.png?width=724&height=334&rev=1.1||alt="1653268155545-638.png" height="334" width="724"]]
172 172  
173 173  
174 174  (((
... ... @@ -180,10 +180,10 @@
180 180  485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively.
181 181  )))
182 182  
183 -[[image:1653268227651-549.png||height="592" width="720"]]
217 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268227651-549.png?width=720&height=592&rev=1.1||alt="1653268227651-549.png" height="592" width="720"]]
184 184  
185 185  (((
186 -The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:
220 +The LG308 is already set to connect to (% class="wikiinternallink" %)[[TTN V3 network >>url:https://www.thethingsnetwork.org/]](%%). So what we need to now is only configure the TTN V3:
187 187  )))
188 188  
189 189  (((
... ... @@ -195,7 +195,7 @@
195 195  )))
196 196  )))
197 197  
198 -[[image:1652953462722-299.png]]
232 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953462722-299.png?rev=1.1||alt="1652953462722-299.png"]]
199 199  
200 200  (((
201 201  (((
... ... @@ -207,21 +207,21 @@
207 207  )))
208 208  )))
209 209  
210 -[[image:image-20220519174512-1.png]]
244 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-1.png?rev=1.1||alt="image-20220519174512-1.png"]]
211 211  
212 -[[image:image-20220519174512-2.png||height="323" width="720"]]
246 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-2.png?width=720&height=323&rev=1.1||alt="image-20220519174512-2.png" height="323" width="720"]]
213 213  
214 -[[image:image-20220519174512-3.png||height="556" width="724"]]
248 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-3.png?width=724&height=556&rev=1.1||alt="image-20220519174512-3.png" height="556" width="724"]]
215 215  
216 -[[image:image-20220519174512-4.png]]
250 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-4.png?rev=1.1||alt="image-20220519174512-4.png"]]
217 217  
218 218  You can also choose to create the device manually.
219 219  
220 -[[image:1652953542269-423.png||height="710" width="723"]]
254 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953542269-423.png?width=723&height=710&rev=1.1||alt="1652953542269-423.png" height="710" width="723"]]
221 221  
222 222  Add APP KEY and DEV EUI
223 223  
224 -[[image:1652953553383-907.png||height="514" width="724"]]
258 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953553383-907.png?width=724&height=514&rev=1.1||alt="1652953553383-907.png" height="514" width="724"]]
225 225  
226 226  
227 227  (((
... ... @@ -228,7 +228,7 @@
228 228  **Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
229 229  )))
230 230  
231 -[[image:1652953568895-172.png||height="232" width="724"]]
265 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953568895-172.png?width=724&height=232&rev=1.1||alt="1652953568895-172.png" height="232" width="724"]]
232 232  
233 233  
234 234  == 3.3 Configure Commands to read data ==
... ... @@ -235,7 +235,7 @@
235 235  
236 236  (((
237 237  (((
238 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
272 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
239 239  )))
240 240  
241 241  (((
... ... @@ -249,19 +249,19 @@
249 249  
250 250  To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
251 251  
252 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
253 -|=(% style="width: 110px;" %)(((
286 +(% border="1" style="background-color:#ffffcc; color:green; width:782px" %)
287 +|(% style="width:128px" %)(((
254 254  **AT Commands**
255 -)))|=(% style="width: 190px;" %)(((
289 +)))|(% style="width:305px" %)(((
256 256  **Description**
257 -)))|=(% style="width: 190px;" %)(((
291 +)))|(% style="width:346px" %)(((
258 258  **Example**
259 259  )))
260 -|(% style="width:110px" %)(((
294 +|(% style="width:128px" %)(((
261 261  AT+BAUDR
262 -)))|(% style="width:190px" %)(((
296 +)))|(% style="width:305px" %)(((
263 263  Set the baud rate (for RS485 connection). Default Value is: 9600.
264 -)))|(% style="width:190px" %)(((
298 +)))|(% style="width:346px" %)(((
265 265  (((
266 266  AT+BAUDR=9600
267 267  )))
... ... @@ -270,11 +270,11 @@
270 270  Options: (1200,2400,4800,14400,19200,115200)
271 271  )))
272 272  )))
273 -|(% style="width:110px" %)(((
307 +|(% style="width:128px" %)(((
274 274  AT+PARITY
275 -)))|(% style="width:190px" %)(((
309 +)))|(% style="width:305px" %)(((
276 276  Set UART parity (for RS485 connection)
277 -)))|(% style="width:190px" %)(((
311 +)))|(% style="width:346px" %)(((
278 278  (((
279 279  AT+PARITY=0
280 280  )))
... ... @@ -283,9 +283,9 @@
283 283  Option: 0: no parity, 1: odd parity, 2: even parity
284 284  )))
285 285  )))
286 -|(% style="width:110px" %)(((
320 +|(% style="width:128px" %)(((
287 287  AT+STOPBIT
288 -)))|(% style="width:190px" %)(((
322 +)))|(% style="width:305px" %)(((
289 289  (((
290 290  Set serial stopbit (for RS485 connection)
291 291  )))
... ... @@ -293,7 +293,7 @@
293 293  (((
294 294  
295 295  )))
296 -)))|(% style="width:190px" %)(((
330 +)))|(% style="width:346px" %)(((
297 297  (((
298 298  AT+STOPBIT=0 for 1bit
299 299  )))
... ... @@ -307,8 +307,6 @@
307 307  )))
308 308  )))
309 309  
310 -
311 -
312 312  === 3.3.2 Configure sensors ===
313 313  
314 314  (((
... ... @@ -317,18 +317,16 @@
317 317  )))
318 318  )))
319 319  
320 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
321 -|=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
322 -|AT+CFGDEV|(% style="width:110px" %)(((
352 +(% border="1" style="background-color:#ffffcc; color:green; width:806px" %)
353 +|**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example**
354 +|AT+CFGDEV|(% style="width:418px" %)(((
323 323  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
324 324  
325 325  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
326 326  
327 327  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
328 -)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
360 +)))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
329 329  
330 -
331 -
332 332  === 3.3.3 Configure read commands for each sampling ===
333 333  
334 334  (((
... ... @@ -374,8 +374,8 @@
374 374  
375 375  **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
376 376  
377 -(% border="1" style="background-color:#4bacc6; color:white; width:510px" %)
378 -|(% style="width:510px" %)(((
407 +(% border="1" style="background-color:#4bacc6; color:white; width:725px" %)
408 +|(% style="width:722px" %)(((
379 379  **AT+DATACUTx=a,b,c**
380 380  
381 381  * **a: length for the return of AT+COMMAND**
... ... @@ -387,17 +387,17 @@
387 387  
388 388  * Grab bytes:
389 389  
390 -[[image:image-20220602153621-1.png]]
420 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-1.png?rev=1.1||alt="image-20220602153621-1.png"]]
391 391  
392 392  
393 393  * Grab a section.
394 394  
395 -[[image:image-20220602153621-2.png]]
425 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-2.png?rev=1.1||alt="image-20220602153621-2.png"]]
396 396  
397 397  
398 398  * Grab different sections.
399 399  
400 -[[image:image-20220602153621-3.png]]
430 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-3.png?rev=1.1||alt="image-20220602153621-3.png"]]
401 401  
402 402  
403 403  )))
... ... @@ -432,7 +432,7 @@
432 432  Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
433 433  )))
434 434  
435 -[[image:1653269759169-150.png||height="513" width="716"]]
465 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653269759169-150.png?width=716&height=513&rev=1.1||alt="1653269759169-150.png" height="513" width="716"]]
436 436  
437 437  
438 438  (% style="color:#037691" %)**Examples: AT+DATAUP=1**
... ... @@ -450,7 +450,7 @@
450 450  1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
451 451  1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes
452 452  
453 -[[image:image-20220602155039-4.png]]
483 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602155039-4.png?rev=1.1||alt="image-20220602155039-4.png"]]
454 454  
455 455  
456 456  So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA
... ... @@ -475,7 +475,7 @@
475 475  
476 476  Below are the uplink payloads:
477 477  
478 -[[image:1654157178836-407.png]]
508 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157178836-407.png?rev=1.1||alt="1654157178836-407.png"]]
479 479  
480 480  
481 481  === 3.3.5 Uplink on demand ===
... ... @@ -494,7 +494,7 @@
494 494  
495 495  RS485-LN support external Interrupt uplink since hardware v1.2 release.
496 496  
497 -[[image:1654157342174-798.png]]
527 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157342174-798.png?rev=1.1||alt="1654157342174-798.png"]]
498 498  
499 499  Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet.
500 500  
... ... @@ -501,9 +501,20 @@
501 501  
502 502  == 3.4 Uplink Payload ==
503 503  
534 +(% border="1" style="background-color:#4bacc6; color:white; width:734px" %)
535 +|**Size(bytes)**|(% style="width:120px" %)**2**|(% style="width:116px" %)**1**|(% style="width:386px" %)**Length depends on the return from the commands**
536 +|Value|(% style="width:120px" %)(((
537 +Battery(mV)
504 504  
505 -[[image:image-20220606110929-1.png]]
539 +&
506 506  
541 +Interrupt _Flag
542 +)))|(% style="width:116px" %)(((
543 +PAYLOAD_VER
544 +
545 +
546 +)))|(% style="width:386px" %)If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server.
547 +
507 507  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
508 508  
509 509  
... ... @@ -513,13 +513,13 @@
513 513  
514 514  There are two kinds of Commands:
515 515  
516 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
557 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
517 517  
518 518  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
519 519  
520 520  === 3.5.1 Common Commands ===
521 521  
522 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
563 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
523 523  
524 524  
525 525  === 3.5.2 Sensor related commands ===
... ... @@ -526,7 +526,7 @@
526 526  
527 527  Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server.
528 528  
529 -[[image:image-20220602163333-5.png||height="263" width="1160"]]
570 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602163333-5.png?width=1160&height=263&rev=1.1||alt="image-20220602163333-5.png" height="263" width="1160"]]
530 530  
531 531  The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable)
532 532  
... ... @@ -588,7 +588,7 @@
588 588  
589 589   **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
590 590  
591 - [[image:1654159460680-153.png]]
632 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654159460680-153.png?rev=1.1||alt="1654159460680-153.png"]]
592 592  
593 593  
594 594  
... ... @@ -615,7 +615,7 @@
615 615  
616 616  AT+COMMANDx or AT+DATACUTx
617 617  
618 -These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
659 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#H3.3.3Configurereadcommandsforeachsampling]].
619 619  
620 620  
621 621  * **AT Command:**
... ... @@ -672,9 +672,9 @@
672 672  * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
673 673  * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
674 674  
675 -[[image:image-20220602165351-6.png]]
716 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-6.png?rev=1.1||alt="image-20220602165351-6.png"]]
676 676  
677 -[[image:image-20220602165351-7.png]]
718 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-7.png?rev=1.1||alt="image-20220602165351-7.png"]]
678 678  
679 679  
680 680  
... ... @@ -712,7 +712,7 @@
712 712  
713 713  Define to use one uplink or multiple uplinks for the sampling.
714 714  
715 -The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
756 +The use of this command please see: [[Compose Uplink payload>>path:#H3.3.4Composetheuplinkpayload]]
716 716  
717 717  * **AT Command:**
718 718  
... ... @@ -741,7 +741,7 @@
741 741  
742 742  * **AT Command:**
743 743  
744 -No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same.
785 +No AT Command for this, user can press the [[ACT button>>path:#H3.7Buttons]] for 1 second for the same.
745 745  
746 746  
747 747  * **Downlink Payload:**
... ... @@ -765,7 +765,7 @@
765 765  
766 766  The uplink screen shot is:
767 767  
768 -[[image:1654160691922-496.png]]
809 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654160691922-496.png?rev=1.1||alt="1654160691922-496.png"]]
769 769  
770 770  
771 771  * **Downlink Payload:**
... ... @@ -822,7 +822,7 @@
822 822  
823 823  RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN.
824 824  
825 -[[image:image-20220602171200-8.png||height="567" width="1007"]]
866 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-8.png?width=1007&height=567&rev=1.1||alt="image-20220602171200-8.png" height="567" width="1007"]]
826 826  
827 827  To enable the listening mode, use can run the command AT+RXMODE.
828 828  
... ... @@ -851,7 +851,7 @@
851 851  
852 852  RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b  (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33
853 853  
854 -[[image:image-20220602171200-9.png]]
895 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-9.png?rev=1.1||alt="image-20220602171200-9.png"]]
855 855  
856 856  
857 857  (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
... ... @@ -864,7 +864,7 @@
864 864  |=**Button**|=(% style="width: 1420px;" %)**Feature**
865 865  |**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
866 866  |**RST**|(% style="width:1420px" %)Reboot RS485
867 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
908 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#H6.1Howtoupgradetheimage3F]]
868 868  
869 869  == 3.8 LEDs ==
870 870  
... ... @@ -875,7 +875,7 @@
875 875  
876 876  = 4. Case Study =
877 877  
878 -User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
919 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>path:/xwiki/bin/view/Main/Application%20Note%20%3A%20Communicate%20with%20Different%20Sensors%20-----%20RS485-LN%20%20RS485-BL/]]
879 879  
880 880  
881 881  = 5. Use AT Command =
... ... @@ -884,15 +884,15 @@
884 884  
885 885  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
886 886  
887 -[[image:1654162355560-817.png]]
928 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162355560-817.png?rev=1.1||alt="1654162355560-817.png"]]
888 888  
889 889  
890 890  In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
891 891  
892 -[[image:1654162368066-342.png]]
933 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162368066-342.png?rev=1.1||alt="1654162368066-342.png"]]
893 893  
894 894  
895 -More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
936 +More detail AT Command manual can be found at [[AT Command Manual>>url:https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
896 896  
897 897  
898 898  == 5.2 Common AT Command Sequence ==
... ... @@ -961,7 +961,7 @@
961 961  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
962 962  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
963 963  
964 -[[image:1654162478620-421.png]]
1005 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162478620-421.png?rev=1.1||alt="1654162478620-421.png"]]
965 965  
966 966  
967 967  = 6. FAQ =
... ... @@ -976,7 +976,7 @@
976 976  
977 977  Below shows the hardware connection for how to upload an image to RS485-LN:
978 978  
979 -[[image:1654162535040-878.png]]
1020 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162535040-878.png?rev=1.1||alt="1654162535040-878.png"]]
980 980  
981 981  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
982 982  
... ... @@ -989,28 +989,28 @@
989 989  )))
990 990  
991 991  
992 -[[image:image-20220602175818-12.png]]
1033 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175818-12.png?rev=1.1||alt="image-20220602175818-12.png"]]
993 993  
994 994  
995 -[[image:image-20220602175848-13.png]]
1036 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175848-13.png?rev=1.1||alt="image-20220602175848-13.png"]]
996 996  
997 997  
998 -[[image:image-20220602175912-14.png]]
1039 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175912-14.png?rev=1.1||alt="image-20220602175912-14.png"]]
999 999  
1000 1000  
1001 1001  **Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1002 1002  
1003 -[[image:image-20220602175638-10.png]]
1044 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175638-10.png?rev=1.1||alt="image-20220602175638-10.png"]]
1004 1004  
1005 1005  
1006 1006  == 6.2 How to change the LoRa Frequency Bands/Region? ==
1007 1007  
1008 -User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
1049 +User can follow the introduction for [[how to upgrade image>>path:#H6.1Howtoupgradetheimage3F]]. When download the images, choose the required image file for download.
1009 1009  
1010 1010  
1011 1011  == 6.3 How many RS485-Slave can RS485-BL connects? ==
1012 1012  
1013 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1054 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#H3.3.3Configurereadcommandsforeachsampling]].
1014 1014  
1015 1015  
1016 1016  == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==
... ... @@ -1017,7 +1017,7 @@
1017 1017  
1018 1018  When user need to use with ChirpStack or TTI. Please set AT+RPL=4.
1019 1019  
1020 -Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]
1061 +Detail info check this link: [[Set Packet Receiving Response Level>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.23SetPacketReceivingResponseLevel]]
1021 1021  
1022 1022  
1023 1023  = 7. Trouble Shooting =
... ... @@ -1024,12 +1024,12 @@
1024 1024  
1025 1025  == 7.1 Downlink doesn’t work, how to solve it? ==
1026 1026  
1027 -Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]]
1068 +Please see this link for debug: [[LoRaWAN Communication Debug>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/]]
1028 1028  
1029 1029  
1030 1030  == 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? ==
1031 1031  
1032 -It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1073 +It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]]
1033 1033  
1034 1034  
1035 1035  = 8. Order Info =
... ... @@ -1049,7 +1049,6 @@
1049 1049  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1050 1050  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1051 1051  
1052 -
1053 1053  = 9.Packing Info =
1054 1054  
1055 1055  
... ... @@ -1066,63 +1066,32 @@
1066 1066  * Package Size / pcs : 14.5 x 8 x 5 cm
1067 1067  * Weight / pcs : 170g
1068 1068  
1069 -
1070 1070  = 10. FCC Caution for RS485LN-US915 =
1071 1071  
1072 -(((
1073 1073  Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
1074 -)))
1075 1075  
1076 -(((
1077 1077  This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
1078 -)))
1079 1079  
1080 -(((
1081 -
1082 -)))
1083 1083  
1084 -(((
1085 1085  **IMPORTANT NOTE:**
1086 -)))
1087 1087  
1088 -(((
1089 1089  **Note: **This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1090 -)))
1091 1091  
1092 -(((
1093 1093  —Reorient or relocate the receiving antenna.
1094 -)))
1095 1095  
1096 -(((
1097 1097  —Increase the separation between the equipment and receiver.
1098 -)))
1099 1099  
1100 -(((
1101 1101  —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
1102 -)))
1103 1103  
1104 -(((
1105 1105  —Consult the dealer or an experienced radio/TV technician for help.
1106 -)))
1107 1107  
1108 -(((
1109 -
1110 -)))
1111 1111  
1112 -(((
1113 1113  **FCC Radiation Exposure Statement:**
1114 -)))
1115 1115  
1116 -(((
1117 1117  This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.
1118 -)))
1119 1119  
1120 1120  
1121 1121  = 11. Support =
1122 1122  
1123 -* (((
1124 -Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1125 -)))
1126 -* (((
1127 -Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
1128 -)))
1136 +* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1137 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
image-20220606110929-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -13.9 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0