Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -103,7 +103,6 @@ 103 103 * Support Modbus protocol 104 104 * Support Interrupt uplink (Since hardware version v1.2) 105 105 106 - 107 107 == 1.4 Applications == 108 108 109 109 * Smart Buildings & Home Automation ... ... @@ -113,7 +113,6 @@ 113 113 * Smart Cities 114 114 * Smart Factory 115 115 116 - 117 117 == 1.5 Firmware Change log == 118 118 119 119 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -307,8 +307,6 @@ 307 307 ))) 308 308 ))) 309 309 310 - 311 - 312 312 === 3.3.2 Configure sensors === 313 313 314 314 ((( ... ... @@ -327,8 +327,6 @@ 327 327 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 328 328 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 329 329 330 - 331 - 332 332 === 3.3.3 Configure read commands for each sampling === 333 333 334 334 ((( ... ... @@ -1087,61 +1087,120 @@ 1087 1087 1088 1088 == 3.6 Listening mode for RS485 network == 1089 1089 1084 +((( 1090 1090 This feature support since firmware v1.4 1086 +))) 1091 1091 1088 +((( 1092 1092 RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN. 1090 +))) 1093 1093 1094 1094 [[image:image-20220602171200-8.png||height="567" width="1007"]] 1095 1095 1094 +((( 1096 1096 To enable the listening mode, use can run the command AT+RXMODE. 1096 +))) 1097 1097 1098 +((( 1099 + 1100 +))) 1098 1098 1099 -(% border="1" style="background-color:#ffffcc; width:500px" %) 1100 -|=(% style="width: 161px;" %)**Command example:**|=(% style="width: 337px;" %)**Function** 1101 -|(% style="width:161px" %)AT+RXMODE=1,10 |(% style="width:337px" %)Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1102 -|(% style="width:161px" %)AT+RXMODE=2,500|(% style="width:337px" %)Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1103 -|(% style="width:161px" %)AT+RXMODE=0,0|(% style="width:337px" %)Disable listening mode. This is the default settings. 1104 -|(% style="width:161px" %) |(% style="width:337px" %)A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 ~| cc) 1102 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1103 +|=(% style="width: 161px;" %)((( 1104 +**Command example:** 1105 +)))|=(% style="width: 337px;" %)((( 1106 +**Function** 1107 +))) 1108 +|(% style="width:161px" %)((( 1109 +AT+RXMODE=1,10 1110 +)))|(% style="width:337px" %)((( 1111 +Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1112 +))) 1113 +|(% style="width:161px" %)((( 1114 +AT+RXMODE=2,500 1115 +)))|(% style="width:337px" %)((( 1116 +Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1117 +))) 1118 +|(% style="width:161px" %)((( 1119 +AT+RXMODE=0,0 1120 +)))|(% style="width:337px" %)((( 1121 +Disable listening mode. This is the default settings. 1122 +))) 1123 +|(% style="width:161px" %)((( 1124 + 1125 +)))|(% style="width:337px" %)((( 1126 +A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1127 +))) 1105 1105 1129 +((( 1106 1106 **Downlink Command:** 1131 +))) 1107 1107 1133 +((( 1108 1108 **0xA6 aa bb cc ** same as AT+RXMODE=aa,(bb<<8 | cc) 1135 +))) 1109 1109 1137 +((( 1138 + 1139 +))) 1110 1110 1141 +((( 1111 1111 **Example**: 1143 +))) 1112 1112 1145 +((( 1113 1113 The RS485-LN is set to AT+RXMODE=2,1000 1147 +))) 1114 1114 1149 +((( 1115 1115 There is a two Modbus commands in the RS485 network as below: 1151 +))) 1116 1116 1153 +((( 1117 1117 The Modbus master send a command: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b 1155 +))) 1118 1118 1157 +((( 1119 1119 And Modbus slave reply with: (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 1159 +))) 1120 1120 1161 +((( 1121 1121 RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 1163 +))) 1122 1122 1165 +((( 1123 1123 [[image:image-20220602171200-9.png]] 1167 +))) 1124 1124 1169 +((( 1170 + 1171 +))) 1125 1125 1173 +((( 1126 1126 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1175 +))) 1127 1127 1128 1128 1129 1129 == 3.7 Buttons == 1130 1130 1131 1131 1132 -(% border="1" style="background-color:#f7faff; width: 500px" %)1133 -|=**Button**|=(% style="width: 1420px;" %)**Feature**1134 -|**ACT**|(% style="width: 1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**1135 -|**RST**|(% style="width: 1420px" %)Reboot RS4851136 -|**PRO**|(% style="width: 1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]1181 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1182 +|=(% style="width: 30px;" %)**Button**|=(% style="width: 355px;" %)**Feature** 1183 +|=(% style="width: 30px;" %)**ACT**|(% style="width:355px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 1184 +|=(% style="width: 30px;" %)**RST**|(% style="width:355px" %)Reboot RS485 1185 +|=(% style="width: 30px;" %)**PRO**|(% style="width:355px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1137 1137 1187 + 1188 + 1138 1138 == 3.8 LEDs == 1139 1139 1140 -(% border="1" style="background-color:#f7faff; width: 500px" %)1141 -|=**LEDs**|=**Feature** 1142 -|**PWR**|Always on if there is power 1143 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %) **fast blink in GREEN**(%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**.**SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.1191 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1192 +|=(% style="width: 30px;" %)**LEDs**|=(% style="width: 400px;" %)**Feature** 1193 +|(% style="width:30px" %)**PWR**|=(% style="width: 400px;" %)Always on if there is power 1194 +|(% style="width:30px" %)**SYS**|=(% style="width: 400px;" %)After device is powered on, the SYS will (% style="color:green" %)fast blink in GREEN (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)on GREEN for 5 seconds(%%). SYS will (% style="color:green" %)blink Blue(%%) on every upload and (% style="color:green" %)blink Green(%%) once receive a downlink message. 1144 1144 1196 + 1197 + 1145 1145 = 4. Case Study = 1146 1146 1147 1147 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -1151,19 +1151,26 @@ 1151 1151 1152 1152 == 5.1 Access AT Command == 1153 1153 1207 +((( 1154 1154 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1209 +))) 1155 1155 1156 1156 [[image:1654162355560-817.png]] 1157 1157 1158 1158 1214 +((( 1159 1159 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1216 +))) 1160 1160 1161 1161 [[image:1654162368066-342.png]] 1162 1162 1163 1163 1221 +((( 1164 1164 More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1223 +))) 1165 1165 1166 1166 1226 + 1167 1167 == 5.2 Common AT Command Sequence == 1168 1168 1169 1169 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === ... ... @@ -1318,7 +1318,6 @@ 1318 1318 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1319 1319 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1320 1320 1321 - 1322 1322 = 9.Packing Info = 1323 1323 1324 1324 ... ... @@ -1335,7 +1335,6 @@ 1335 1335 * Package Size / pcs : 14.5 x 8 x 5 cm 1336 1336 * Weight / pcs : 170g 1337 1337 1338 - 1339 1339 = 10. FCC Caution for RS485LN-US915 = 1340 1340 1341 1341 (((