From version < 58.19 >
edited by Xiaoling
on 2022/06/06 11:24
To version < 58.30 >
edited by Xiaoling
on 2022/06/06 11:42
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,5 @@
1 1  (% style="text-align:center" %)
2 -[[image:1653266934636-343.png||height="385" width="385"]]
2 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653266934636-343.png?width=385&height=385&rev=1.1||alt="1653266934636-343.png" height="385" width="385"]]
3 3  
4 4  
5 5  
... ... @@ -10,7 +10,59 @@
10 10  
11 11  **Table of Contents:**
12 12  
13 -{{toc/}}
13 +* [[1.Introduction>>path:#H1.Introduction]]
14 +** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>path:#H1.1A0WhatisRS485-LNRS485toLoRaWANConverter]]
15 +** [[1.2 Specifications>>path:#H1.2A0Specifications]]
16 +** [[1.3 Features>>path:#H1.3Features]]
17 +** [[1.4 Applications>>path:#H1.4A0Applications]]
18 +** [[1.5 Firmware Change log>>path:#H1.5A0FirmwareChangelog]]
19 +** [[1.6 Hardware Change log>>path:#H1.6HardwareChangelog]]
20 +* [[2. Power ON Device>>path:#H2.PowerONDevice]]
21 +* [[3. Operation Mode>>path:#H3.A0OperationMode]]
22 +** [[3.1 How it works?>>path:#H3.1Howitworks3F]]
23 +** [[3.2 Example to join LoRaWAN network>>path:#H3.2ExampletojoinLoRaWANnetwork]]
24 +** [[3.3 Configure Commands to read data>>path:#H3.3ConfigureCommandstoreaddata]]
25 +*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>path:#H3.3.1onfigureUARTsettingsforRS485orTTLcommunication]]
26 +*** [[3.3.2 Configure sensors>>path:#H3.3.2Configuresensors]]
27 +*** [[3.3.3 Configure read commands for each sampling>>path:#H3.3.3Configurereadcommandsforeachsampling]]
28 +*** [[3.3.4 Compose the uplink payload>>path:#H3.3.4Composetheuplinkpayload]]
29 +*** [[3.3.5 Uplink on demand>>path:#H3.3.5Uplinkondemand]]
30 +*** [[3.3.6 Uplink on Interrupt>>path:#H3.3.6UplinkonInterrupt]]
31 +** [[3.4 Uplink Payload>>path:#H3.4UplinkPayload]]
32 +** [[3.5 Configure RS485-BL via AT or Downlink>>path:#H3.5ConfigureRS485-BLviaATorDownlink]]
33 +*** [[3.5.1 Common Commands>>path:#H3.5.1CommonCommands]]
34 +*** [[3.5.2 Sensor related commands>>path:#H3.5.2Sensorrelatedcommands]]
35 +*** [[3.5.3 Sensor related commands>>path:#H3.5.3A0Sensorrelatedcommands]]
36 +**** [[RS485 Debug Command>>path:#HRS485DebugCommand]]
37 +**** [[Set Payload version>>path:#HSetPayloadversion]]
38 +**** [[Set RS485 Sampling Commands>>path:#HSetRS485SamplingCommands]]
39 +**** [[Fast command to handle MODBUS device>>path:#HFastcommandtohandleMODBUSdevice]]
40 +**** [[RS485 command timeout>>path:#HRS485commandtimeout]]
41 +**** [[Uplink payload mode>>path:#HUplinkpayloadmode]]
42 +**** [[Manually trigger an Uplink>>path:#HManuallytriggeranUplink]]
43 +**** [[Clear RS485 Command>>path:#HClearRS485Command]]
44 +**** [[Set Serial Communication Parameters>>path:#HSetSerialCommunicationParameters]]
45 +** [[3.6 Listening mode for RS485 network>>path:#H3.6A0ListeningmodeforRS485network]]
46 +** [[3.7 Buttons>>path:#H3.7Buttons]]
47 +** [[3.8 LEDs>>path:#H3.8LEDs]]
48 +* [[4. Case Study>>path:#H4.CaseStudy]]
49 +* [[5. Use AT Command>>path:#H5.UseATCommand]]
50 +** [[5.1 Access AT Command>>path:#H5.1AccessATCommand]]
51 +** [[5.2 Common AT Command Sequence>>path:#H5.2CommonATCommandSequence]]
52 +*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>path:#H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829]]
53 +*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>path:#H5.5.2Single-channelABPmode28UsewithLG012FLG0229]]
54 +* [[6. FAQ>>path:#H6.FAQ]]
55 +** [[6.1 How to upgrade the image?>>path:#H6.1Howtoupgradetheimage3F]]
56 +** [[6.2 How to change the LoRa Frequency Bands/Region?>>path:#H6.2HowtochangetheLoRaFrequencyBands2FRegion3F]]
57 +** [[6.3 How many RS485-Slave can RS485-BL connects?>>path:#H6.3HowmanyRS485-SlavecanRS485-BLconnects3F]]
58 +** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>path:#H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F]]
59 +* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
60 +** [[7.1 Downlink doesn’t work, how to solve it?>>path:#H7.1Downlinkdoesn2019twork2Chowtosolveit3F]]
61 +** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>path:#H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F]]
62 +* [[8. Order Info>>path:#H8.OrderInfo]]
63 +* [[9.Packing Info>>path:#H9.PackingInfo]]
64 +* [[10. FCC Caution for RS485LN-US915>>path:#H10.FCCCautionforRS485LN-US915]]
65 +* [[11. Support>>path:#H11.Support]]
14 14  
15 15  
16 16  
... ... @@ -52,7 +52,7 @@
52 52  )))
53 53  )))
54 54  
55 -[[image:1653267211009-519.png||height="419" width="724"]]
107 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653267211009-519.png?width=724&height=419&rev=1.1||alt="1653267211009-519.png" height="419" width="724"]]
56 56  
57 57  
58 58  == 1.2 Specifications ==
... ... @@ -103,7 +103,6 @@
103 103  * Support Modbus protocol
104 104  * Support Interrupt uplink (Since hardware version v1.2)
105 105  
106 -
107 107  == 1.4 Applications ==
108 108  
109 109  * Smart Buildings & Home Automation
... ... @@ -113,7 +113,6 @@
113 113  * Smart Cities
114 114  * Smart Factory
115 115  
116 -
117 117  == 1.5 Firmware Change log ==
118 118  
119 119  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -147,7 +147,7 @@
147 147  Once there is power, the RS485-LN will be on.
148 148  )))
149 149  
150 -[[image:1653268091319-405.png]]
200 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268091319-405.png?rev=1.1||alt="1653268091319-405.png"]]
151 151  
152 152  
153 153  )))
... ... @@ -168,7 +168,7 @@
168 168  
169 169  Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
170 170  
171 -[[image:1653268155545-638.png||height="334" width="724"]]
221 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268155545-638.png?width=724&height=334&rev=1.1||alt="1653268155545-638.png" height="334" width="724"]]
172 172  
173 173  
174 174  (((
... ... @@ -180,10 +180,10 @@
180 180  485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively.
181 181  )))
182 182  
183 -[[image:1653268227651-549.png||height="592" width="720"]]
233 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268227651-549.png?width=720&height=592&rev=1.1||alt="1653268227651-549.png" height="592" width="720"]]
184 184  
185 185  (((
186 -The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:
236 +The LG308 is already set to connect to (% class="wikiinternallink" %)[[TTN V3 network >>url:https://www.thethingsnetwork.org/]](%%). So what we need to now is only configure the TTN V3:
187 187  )))
188 188  
189 189  (((
... ... @@ -195,7 +195,7 @@
195 195  )))
196 196  )))
197 197  
198 -[[image:1652953462722-299.png]]
248 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953462722-299.png?rev=1.1||alt="1652953462722-299.png"]]
199 199  
200 200  (((
201 201  (((
... ... @@ -207,21 +207,21 @@
207 207  )))
208 208  )))
209 209  
210 -[[image:image-20220519174512-1.png]]
260 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-1.png?rev=1.1||alt="image-20220519174512-1.png"]]
211 211  
212 -[[image:image-20220519174512-2.png||height="323" width="720"]]
262 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-2.png?width=720&height=323&rev=1.1||alt="image-20220519174512-2.png" height="323" width="720"]]
213 213  
214 -[[image:image-20220519174512-3.png||height="556" width="724"]]
264 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-3.png?width=724&height=556&rev=1.1||alt="image-20220519174512-3.png" height="556" width="724"]]
215 215  
216 -[[image:image-20220519174512-4.png]]
266 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-4.png?rev=1.1||alt="image-20220519174512-4.png"]]
217 217  
218 218  You can also choose to create the device manually.
219 219  
220 -[[image:1652953542269-423.png||height="710" width="723"]]
270 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953542269-423.png?width=723&height=710&rev=1.1||alt="1652953542269-423.png" height="710" width="723"]]
221 221  
222 222  Add APP KEY and DEV EUI
223 223  
224 -[[image:1652953553383-907.png||height="514" width="724"]]
274 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953553383-907.png?width=724&height=514&rev=1.1||alt="1652953553383-907.png" height="514" width="724"]]
225 225  
226 226  
227 227  (((
... ... @@ -228,7 +228,7 @@
228 228  **Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
229 229  )))
230 230  
231 -[[image:1652953568895-172.png||height="232" width="724"]]
281 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953568895-172.png?width=724&height=232&rev=1.1||alt="1652953568895-172.png" height="232" width="724"]]
232 232  
233 233  
234 234  == 3.3 Configure Commands to read data ==
... ... @@ -235,7 +235,7 @@
235 235  
236 236  (((
237 237  (((
238 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
288 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
239 239  )))
240 240  
241 241  (((
... ... @@ -307,8 +307,6 @@
307 307  )))
308 308  )))
309 309  
310 -
311 -
312 312  === 3.3.2 Configure sensors ===
313 313  
314 314  (((
... ... @@ -327,8 +327,6 @@
327 327  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
328 328  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
329 329  
330 -
331 -
332 332  === 3.3.3 Configure read commands for each sampling ===
333 333  
334 334  (((
... ... @@ -387,17 +387,17 @@
387 387  
388 388  * Grab bytes:
389 389  
390 -[[image:image-20220602153621-1.png]]
436 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-1.png?rev=1.1||alt="image-20220602153621-1.png"]]
391 391  
392 392  
393 393  * Grab a section.
394 394  
395 -[[image:image-20220602153621-2.png]]
441 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-2.png?rev=1.1||alt="image-20220602153621-2.png"]]
396 396  
397 397  
398 398  * Grab different sections.
399 399  
400 -[[image:image-20220602153621-3.png]]
446 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-3.png?rev=1.1||alt="image-20220602153621-3.png"]]
401 401  
402 402  
403 403  )))
... ... @@ -432,7 +432,7 @@
432 432  Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
433 433  )))
434 434  
435 -[[image:1653269759169-150.png||height="513" width="716"]]
481 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653269759169-150.png?width=716&height=513&rev=1.1||alt="1653269759169-150.png" height="513" width="716"]]
436 436  
437 437  
438 438  (% style="color:#037691" %)**Examples: AT+DATAUP=1**
... ... @@ -450,7 +450,7 @@
450 450  1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
451 451  1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes
452 452  
453 -[[image:image-20220602155039-4.png]]
499 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602155039-4.png?rev=1.1||alt="image-20220602155039-4.png"]]
454 454  
455 455  
456 456  So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA
... ... @@ -475,7 +475,7 @@
475 475  
476 476  Below are the uplink payloads:
477 477  
478 -[[image:1654157178836-407.png]]
524 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157178836-407.png?rev=1.1||alt="1654157178836-407.png"]]
479 479  
480 480  
481 481  === 3.3.5 Uplink on demand ===
... ... @@ -494,7 +494,7 @@
494 494  
495 495  RS485-LN support external Interrupt uplink since hardware v1.2 release.
496 496  
497 -[[image:1654157342174-798.png]]
543 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157342174-798.png?rev=1.1||alt="1654157342174-798.png"]]
498 498  
499 499  Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet.
500 500  
... ... @@ -502,7 +502,7 @@
502 502  == 3.4 Uplink Payload ==
503 503  
504 504  
505 -[[image:image-20220606110929-1.png]]
551 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220606110929-1.png?rev=1.1||alt="image-20220606110929-1.png"]]
506 506  
507 507  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
508 508  
... ... @@ -518,7 +518,7 @@
518 518  )))
519 519  
520 520  * (((
521 -(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
567 +(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
522 522  )))
523 523  
524 524  * (((
... ... @@ -532,7 +532,7 @@
532 532  
533 533  === 3.5.1 Common Commands ===
534 534  
535 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
581 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
536 536  
537 537  
538 538  === 3.5.2 Sensor related commands ===
... ... @@ -539,7 +539,7 @@
539 539  
540 540  Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server.
541 541  
542 -[[image:image-20220602163333-5.png||height="263" width="1160"]]
588 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602163333-5.png?width=1160&height=263&rev=1.1||alt="image-20220602163333-5.png" height="263" width="1160"]]
543 543  
544 544  The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable)
545 545  
... ... @@ -664,7 +664,7 @@
664 664  )))
665 665  
666 666  (((
667 - [[image:1654159460680-153.png]]
713 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654159460680-153.png?rev=1.1||alt="1654159460680-153.png"]]
668 668  )))
669 669  
670 670  
... ... @@ -709,7 +709,7 @@
709 709  )))
710 710  
711 711  (((
712 -These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
758 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#H3.3.3Configurereadcommandsforeachsampling]].
713 713  )))
714 714  
715 715  (((
... ... @@ -825,9 +825,9 @@
825 825  AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
826 826  )))
827 827  
828 -[[image:image-20220602165351-6.png]]
874 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-6.png?rev=1.1||alt="image-20220602165351-6.png"]]
829 829  
830 -[[image:image-20220602165351-7.png]]
876 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-7.png?rev=1.1||alt="image-20220602165351-7.png"]]
831 831  
832 832  
833 833  
... ... @@ -895,7 +895,7 @@
895 895  )))
896 896  
897 897  (((
898 -The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
944 +The use of this command please see: [[Compose Uplink payload>>path:#H3.3.4Composetheuplinkpayload]]
899 899  )))
900 900  
901 901  * (((
... ... @@ -946,7 +946,7 @@
946 946  )))
947 947  
948 948  (((
949 -No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same.
995 +No AT Command for this, user can press the [[ACT button>>path:#H3.7Buttons]] for 1 second for the same.
950 950  )))
951 951  
952 952  (((
... ... @@ -994,7 +994,7 @@
994 994  The uplink screen shot is:
995 995  )))
996 996  
997 -[[image:1654160691922-496.png]]
1043 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654160691922-496.png?rev=1.1||alt="1654160691922-496.png"]]
998 998  
999 999  
1000 1000  * (((
... ... @@ -1087,64 +1087,121 @@
1087 1087  
1088 1088  == 3.6 Listening mode for RS485 network ==
1089 1089  
1136 +(((
1090 1090  This feature support since firmware v1.4
1138 +)))
1091 1091  
1140 +(((
1092 1092  RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN.
1142 +)))
1093 1093  
1094 -[[image:image-20220602171200-8.png||height="567" width="1007"]]
1144 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-8.png?width=1007&height=567&rev=1.1||alt="image-20220602171200-8.png" height="567" width="1007"]]
1095 1095  
1146 +(((
1096 1096  To enable the listening mode, use can run the command AT+RXMODE.
1148 +)))
1097 1097  
1150 +(((
1151 +
1152 +)))
1098 1098  
1099 -(% border="1" style="background-color:#ffffcc; width:500px" %)
1100 -|=(% style="width: 161px;" %)**Command example:**|=(% style="width: 337px;" %)**Function**
1101 -|(% style="width:161px" %)AT+RXMODE=1,10 |(% style="width:337px" %)Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
1102 -|(% style="width:161px" %)AT+RXMODE=2,500|(% style="width:337px" %)Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
1103 -|(% style="width:161px" %)AT+RXMODE=0,0|(% style="width:337px" %)Disable listening mode. This is the default settings.
1104 -|(% style="width:161px" %) |(% style="width:337px" %)A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 ~| cc)
1154 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
1155 +|=(% style="width: 161px;" %)(((
1156 +**Command example:**
1157 +)))|=(% style="width: 337px;" %)(((
1158 +**Function**
1159 +)))
1160 +|(% style="width:161px" %)(((
1161 +AT+RXMODE=1,10
1162 +)))|(% style="width:337px" %)(((
1163 +Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
1164 +)))
1165 +|(% style="width:161px" %)(((
1166 +AT+RXMODE=2,500
1167 +)))|(% style="width:337px" %)(((
1168 +Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
1169 +)))
1170 +|(% style="width:161px" %)(((
1171 +AT+RXMODE=0,0
1172 +)))|(% style="width:337px" %)(((
1173 +Disable listening mode. This is the default settings.
1174 +)))
1175 +|(% style="width:161px" %)(((
1176 +
1177 +)))|(% style="width:337px" %)(((
1178 +A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 | cc)
1179 +)))
1105 1105  
1181 +(((
1106 1106  **Downlink Command:**
1183 +)))
1107 1107  
1185 +(((
1108 1108  **0xA6 aa bb cc ** same as AT+RXMODE=aa,(bb<<8 | cc)
1187 +)))
1109 1109  
1189 +(((
1190 +
1191 +)))
1110 1110  
1193 +(((
1111 1111  **Example**:
1195 +)))
1112 1112  
1197 +(((
1113 1113  The RS485-LN is set to AT+RXMODE=2,1000
1199 +)))
1114 1114  
1201 +(((
1115 1115  There is a two Modbus commands in the RS485 network as below:
1203 +)))
1116 1116  
1205 +(((
1117 1117  The Modbus master send a command: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b
1207 +)))
1118 1118  
1209 +(((
1119 1119  And Modbus slave reply with: (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33
1211 +)))
1120 1120  
1213 +(((
1121 1121  RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b  (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33
1215 +)))
1122 1122  
1123 -[[image:image-20220602171200-9.png]]
1217 +(((
1218 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-9.png?rev=1.1||alt="image-20220602171200-9.png"]]
1219 +)))
1124 1124  
1221 +(((
1222 +
1223 +)))
1125 1125  
1225 +(((
1126 1126  (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
1227 +)))
1127 1127  
1128 1128  
1129 1129  == 3.7 Buttons ==
1130 1130  
1131 1131  
1132 -(% border="1" style="background-color:#f7faff; width:500px" %)
1133 -|=**Button**|=(% style="width: 1420px;" %)**Feature**
1134 -|**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1135 -|**RST**|(% style="width:1420px" %)Reboot RS485
1136 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1233 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1234 +|=(% style="width: 30px;" %)**Button**|=(% style="width: 355px;" %)**Feature**
1235 +|=(% style="width: 30px;" %)**ACT**|(% style="width:355px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1236 +|=(% style="width: 30px;" %)**RST**|(% style="width:355px" %)Reboot RS485
1237 +|=(% style="width: 30px;" %)**PRO**|(% style="width:355px" %)Use for upload image, see [[How to Update Image>>path:#H6.1Howtoupgradetheimage3F]]
1137 1137  
1239 +
1138 1138  == 3.8 LEDs ==
1139 1139  
1140 -(% border="1" style="background-color:#f7faff; width:500px" %)
1141 -|=**LEDs**|=**Feature**
1142 -|**PWR**|Always on if there is power
1143 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1242 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)
1243 +|=(% style="width: 30px;" %)**LEDs**|=(% style="width: 400px;" %)**Feature**
1244 +|(% style="width:30px" %)**PWR**|=(% style="width: 400px;" %)Always on if there is power
1245 +|(% style="width:30px" %)**SYS**|=(% style="width: 400px;" %)After device is powered on, the SYS will (% style="color:green" %)fast blink in GREEN (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)on GREEN for 5 seconds(%%). SYS will (% style="color:green" %)blink Blue(%%) on every upload and (% style="color:green" %)blink Green(%%) once receive a downlink message.
1144 1144  
1247 +
1145 1145  = 4. Case Study =
1146 1146  
1147 -User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1250 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>path:/xwiki/bin/view/Main/Application%20Note%20%3A%20Communicate%20with%20Different%20Sensors%20-----%20RS485-LN%20%20RS485-BL/]]
1148 1148  
1149 1149  
1150 1150  = 5. Use AT Command =
... ... @@ -1151,19 +1151,26 @@
1151 1151  
1152 1152  == 5.1 Access AT Command ==
1153 1153  
1257 +(((
1154 1154  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1259 +)))
1155 1155  
1156 -[[image:1654162355560-817.png]]
1261 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162355560-817.png?rev=1.1||alt="1654162355560-817.png"]]
1157 1157  
1158 1158  
1264 +(((
1159 1159  In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1266 +)))
1160 1160  
1161 -[[image:1654162368066-342.png]]
1268 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162368066-342.png?rev=1.1||alt="1654162368066-342.png"]]
1162 1162  
1163 1163  
1164 -More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1271 +(((
1272 +More detail AT Command manual can be found at [[AT Command Manual>>url:https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1273 +)))
1165 1165  
1166 1166  
1276 +
1167 1167  == 5.2 Common AT Command Sequence ==
1168 1168  
1169 1169  === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
... ... @@ -1230,7 +1230,7 @@
1230 1230  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1231 1231  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1232 1232  
1233 -[[image:1654162478620-421.png]]
1343 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162478620-421.png?rev=1.1||alt="1654162478620-421.png"]]
1234 1234  
1235 1235  
1236 1236  = 6. FAQ =
... ... @@ -1245,7 +1245,7 @@
1245 1245  
1246 1246  Below shows the hardware connection for how to upload an image to RS485-LN:
1247 1247  
1248 -[[image:1654162535040-878.png]]
1358 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162535040-878.png?rev=1.1||alt="1654162535040-878.png"]]
1249 1249  
1250 1250  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1251 1251  
... ... @@ -1258,28 +1258,28 @@
1258 1258  )))
1259 1259  
1260 1260  
1261 -[[image:image-20220602175818-12.png]]
1371 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175818-12.png?rev=1.1||alt="image-20220602175818-12.png"]]
1262 1262  
1263 1263  
1264 -[[image:image-20220602175848-13.png]]
1374 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175848-13.png?rev=1.1||alt="image-20220602175848-13.png"]]
1265 1265  
1266 1266  
1267 -[[image:image-20220602175912-14.png]]
1377 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175912-14.png?rev=1.1||alt="image-20220602175912-14.png"]]
1268 1268  
1269 1269  
1270 1270  **Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1271 1271  
1272 -[[image:image-20220602175638-10.png]]
1382 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175638-10.png?rev=1.1||alt="image-20220602175638-10.png"]]
1273 1273  
1274 1274  
1275 1275  == 6.2 How to change the LoRa Frequency Bands/Region? ==
1276 1276  
1277 -User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
1387 +User can follow the introduction for [[how to upgrade image>>path:#H6.1Howtoupgradetheimage3F]]. When download the images, choose the required image file for download.
1278 1278  
1279 1279  
1280 1280  == 6.3 How many RS485-Slave can RS485-BL connects? ==
1281 1281  
1282 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1392 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#H3.3.3Configurereadcommandsforeachsampling]].
1283 1283  
1284 1284  
1285 1285  == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==
... ... @@ -1286,7 +1286,7 @@
1286 1286  
1287 1287  When user need to use with ChirpStack or TTI. Please set AT+RPL=4.
1288 1288  
1289 -Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]
1399 +Detail info check this link: [[Set Packet Receiving Response Level>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.23SetPacketReceivingResponseLevel]]
1290 1290  
1291 1291  
1292 1292  = 7. Trouble Shooting =
... ... @@ -1293,12 +1293,12 @@
1293 1293  
1294 1294  == 7.1 Downlink doesn’t work, how to solve it? ==
1295 1295  
1296 -Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]]
1406 +Please see this link for debug: [[LoRaWAN Communication Debug>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/]]
1297 1297  
1298 1298  
1299 1299  == 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? ==
1300 1300  
1301 -It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1411 +It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]]
1302 1302  
1303 1303  
1304 1304  = 8. Order Info =
... ... @@ -1318,7 +1318,6 @@
1318 1318  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1319 1319  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1320 1320  
1321 -
1322 1322  = 9.Packing Info =
1323 1323  
1324 1324  
... ... @@ -1335,7 +1335,6 @@
1335 1335  * Package Size / pcs : 14.5 x 8 x 5 cm
1336 1336  * Weight / pcs : 170g
1337 1337  
1338 -
1339 1339  = 10. FCC Caution for RS485LN-US915 =
1340 1340  
1341 1341  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0