From version < 58.19 >
edited by Xiaoling
on 2022/06/06 11:24
To version < 58.25 >
edited by Xiaoling
on 2022/06/06 11:27
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1087,61 +1087,120 @@
1087 1087  
1088 1088  == 3.6 Listening mode for RS485 network ==
1089 1089  
1090 +(((
1090 1090  This feature support since firmware v1.4
1092 +)))
1091 1091  
1094 +(((
1092 1092  RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN.
1096 +)))
1093 1093  
1094 1094  [[image:image-20220602171200-8.png||height="567" width="1007"]]
1095 1095  
1100 +(((
1096 1096  To enable the listening mode, use can run the command AT+RXMODE.
1102 +)))
1097 1097  
1104 +(((
1105 +
1106 +)))
1098 1098  
1099 -(% border="1" style="background-color:#ffffcc; width:500px" %)
1100 -|=(% style="width: 161px;" %)**Command example:**|=(% style="width: 337px;" %)**Function**
1101 -|(% style="width:161px" %)AT+RXMODE=1,10 |(% style="width:337px" %)Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
1102 -|(% style="width:161px" %)AT+RXMODE=2,500|(% style="width:337px" %)Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
1103 -|(% style="width:161px" %)AT+RXMODE=0,0|(% style="width:337px" %)Disable listening mode. This is the default settings.
1104 -|(% style="width:161px" %) |(% style="width:337px" %)A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 ~| cc)
1108 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
1109 +|=(% style="width: 161px;" %)(((
1110 +**Command example:**
1111 +)))|=(% style="width: 337px;" %)(((
1112 +**Function**
1113 +)))
1114 +|(% style="width:161px" %)(((
1115 +AT+RXMODE=1,10
1116 +)))|(% style="width:337px" %)(((
1117 +Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
1118 +)))
1119 +|(% style="width:161px" %)(((
1120 +AT+RXMODE=2,500
1121 +)))|(% style="width:337px" %)(((
1122 +Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
1123 +)))
1124 +|(% style="width:161px" %)(((
1125 +AT+RXMODE=0,0
1126 +)))|(% style="width:337px" %)(((
1127 +Disable listening mode. This is the default settings.
1128 +)))
1129 +|(% style="width:161px" %)(((
1130 +
1131 +)))|(% style="width:337px" %)(((
1132 +A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 | cc)
1133 +)))
1105 1105  
1135 +(((
1106 1106  **Downlink Command:**
1137 +)))
1107 1107  
1139 +(((
1108 1108  **0xA6 aa bb cc ** same as AT+RXMODE=aa,(bb<<8 | cc)
1141 +)))
1109 1109  
1143 +(((
1144 +
1145 +)))
1110 1110  
1147 +(((
1111 1111  **Example**:
1149 +)))
1112 1112  
1151 +(((
1113 1113  The RS485-LN is set to AT+RXMODE=2,1000
1153 +)))
1114 1114  
1155 +(((
1115 1115  There is a two Modbus commands in the RS485 network as below:
1157 +)))
1116 1116  
1159 +(((
1117 1117  The Modbus master send a command: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b
1161 +)))
1118 1118  
1163 +(((
1119 1119  And Modbus slave reply with: (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33
1165 +)))
1120 1120  
1167 +(((
1121 1121  RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b  (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33
1169 +)))
1122 1122  
1171 +(((
1123 1123  [[image:image-20220602171200-9.png]]
1173 +)))
1124 1124  
1175 +(((
1176 +
1177 +)))
1125 1125  
1179 +(((
1126 1126  (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
1181 +)))
1127 1127  
1128 1128  
1129 1129  == 3.7 Buttons ==
1130 1130  
1131 1131  
1132 -(% border="1" style="background-color:#f7faff; width:500px" %)
1187 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)
1133 1133  |=**Button**|=(% style="width: 1420px;" %)**Feature**
1134 1134  |**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1135 1135  |**RST**|(% style="width:1420px" %)Reboot RS485
1136 1136  |**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1137 1137  
1193 +
1194 +
1138 1138  == 3.8 LEDs ==
1139 1139  
1140 -(% border="1" style="background-color:#f7faff; width:500px" %)
1197 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)
1141 1141  |=**LEDs**|=**Feature**
1142 1142  |**PWR**|Always on if there is power
1143 1143  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1144 1144  
1202 +
1203 +
1145 1145  = 4. Case Study =
1146 1146  
1147 1147  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1151,12 +1151,16 @@
1151 1151  
1152 1152  == 5.1 Access AT Command ==
1153 1153  
1213 +(((
1154 1154  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1215 +)))
1155 1155  
1156 1156  [[image:1654162355560-817.png]]
1157 1157  
1158 1158  
1220 +(((
1159 1159  In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1222 +)))
1160 1160  
1161 1161  [[image:1654162368066-342.png]]
1162 1162  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0