Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -937,29 +937,16 @@ 937 937 938 938 ==== **Manually trigger an Uplink** ==== 939 939 940 -((( 941 941 Ask device to send an uplink immediately. 942 -))) 943 943 944 -* ((( 945 -**AT Command:** 946 -))) 942 +* **AT Command:** 947 947 948 -((( 949 949 No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same. 950 -))) 951 951 952 -((( 953 - 954 -))) 955 955 956 -* ((( 957 -**Downlink Payload:** 958 -))) 947 +* **Downlink Payload:** 959 959 960 -((( 961 961 **0x08 FF**, RS485-LN will immediately send an uplink. 962 -))) 963 963 964 964 965 965 ... ... @@ -966,33 +966,18 @@ 966 966 967 967 ==== **Clear RS485 Command** ==== 968 968 969 -((( 970 970 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 971 -))) 972 972 973 -* ((( 974 -**AT Command:** 975 -))) 958 +* **AT Command:** 976 976 977 -((( 978 978 **AT+CMDEAR=mm,nn** mm: start position of erase ,nn: stop position of erase 979 -))) 980 980 981 -((( 982 982 Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 983 -))) 984 984 985 -((( 986 986 Example screen shot after clear all RS485 commands. 987 -))) 988 988 989 -((( 990 - 991 -))) 992 992 993 -((( 994 994 The uplink screen shot is: 995 -))) 996 996 997 997 [[image:1654160691922-496.png]] 998 998