82 82  * Automatic RF Sense and CAD with ultra-fast AFC.
83 83  * Packet engine up to 256 bytes with CRC
84 84  
85 -
86 -
87 87  == 1.3 Features ==
88 88  
89 89  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -95,8 +95,6 @@
95 95  * Support Modbus protocol
96 96  * Support Interrupt uplink (Since hardware version v1.2)
97 97  
98 -
99 -
100 100  == 1.4 Applications ==
101 101  
102 102  * Smart Buildings & Home Automation
... ... @@ -106,8 +106,6 @@
106 106  * Smart Cities
107 107  * Smart Factory
108 108  
109 -
110 -
111 111  == 1.5 Firmware Change log ==
112 112  
113 113  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -223,7 +223,7 @@
223 223  
224 224  (((
225 225  (((
226 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#AT_COMMAND]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
220 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
227 227  )))
228 228  
229 229  (((
... ... @@ -428,6 +428,7 @@
428 428  
429 429  (% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
430 430  
425 +
431 431  1. PAYVER: Defined by AT+PAYVER
432 432  1. PAYLOAD COUNT: Total how many uplinks of this sampling.
433 433  1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
... ... @@ -507,7 +507,7 @@
507 507  
508 508  There are two kinds of Commands:
509 509  
510 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
505 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
511 511  
512 512  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
513 513  
... ... @@ -527,8 +527,6 @@
527 527  
528 528  === 3.5.3 Sensor related commands ===
529 529  
530 -(% class="wikigeneratedid" id="H" %)
531 -
532 532  
533 533  
534 534  ==== **RS485 Debug Command** ====
... ... @@ -737,7 +737,7 @@
737 737  
738 738  * **AT Command:**
739 739  
740 -No AT Command for this, user can press the [[ACT button>>path:#Button]] for 1 second for the same.
733 +No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same.
741 741  
742 742  
743 743  * **Downlink Payload:**
... ... @@ -745,7 +745,6 @@
745 745  **0x08 FF**, RS485-LN will immediately send an uplink.
746 746  
747 747  
748 -==== ====
749 749  
750 750  ==== **Clear RS485 Command** ====
751 751  
... ... @@ -762,7 +762,7 @@
762 762  
763 763  The uplink screen shot is:
764 764  
765 -[[image:1654160691922-496.png]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]]
757 +[[image:1654160691922-496.png]]
766 766  
767 767  
768 768  * **Downlink Payload:**
... ... @@ -861,10 +861,9 @@
861 861  |=**Button**|=(% style="width: 1420px;" %)**Feature**
862 862  |**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
863 863  |**RST**|(% style="width:1420px" %)Reboot RS485
864 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#upgrade_image]]
856 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
865 865  
866 866  
867 -
868 868  == 3.8 LEDs ==
869 869  
870 870  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -873,7 +873,6 @@
873 873  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
874 874  
875 875  
876 -
877 877  = 4. Case Study =
878 878  
879 879  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -893,7 +893,7 @@
893 893  [[image:1654162368066-342.png]]
894 894  
895 895  
896 -More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]
886 +More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
897 897  
898 898  
899 899  == 5.2 Common AT Command Sequence ==
... ... @@ -985,7 +985,9 @@
985 985  
986 986  **Step3: **Open flashloader; choose the correct COM port to update.
987 987  
978 +(((
988 988  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
980 +)))
989 989  
990 990  
991 991  [[image:image-20220602175818-12.png]]
... ... @@ -1066,29 +1066,57 @@
1066 1066  * Package Size / pcs : 14.5 x 8 x 5 cm
1067 1067  * Weight / pcs : 170g
1068 1068  
1061 +
1062 +
1069 1069  = 10. FCC Caution for RS485LN-US915 =
1070 1070  
1065 +(((
1071 1071  Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
1067 +)))
1072 1072  
1069 +(((
1073 1073  This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
1071 +)))
1074 1074  
1073 +(((
1074 +
1075 +)))
1075 1075  
1077 +(((
1076 1076  **IMPORTANT NOTE:**
1079 +)))
1077 1077  
1081 +(((
1078 1078  **Note: **This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1083 +)))
1079 1079  
1085 +(((
1080 1080  —Reorient or relocate the receiving antenna.
1087 +)))
1081 1081  
1089 +(((
1082 1082  —Increase the separation between the equipment and receiver.
1091 +)))
1083 1083  
1093 +(((
1084 1084  —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
1095 +)))
1085 1085  
1097 +(((
1086 1086  —Consult the dealer or an experienced radio/TV technician for help.
1099 +)))
1087 1087  
1101 +(((
1102 +
1103 +)))
1088 1088  
1105 +(((
1089 1089  **FCC Radiation Exposure Statement:**
1107 +)))
1090 1090  
1109 +(((
1091 1091  This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.
1111 +)))
1092 1092  
1093 1093  
1094 1094  = 11. Support =
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0