Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Karry Zhuang on 2025/03/06 16:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 5 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,18 +6,12 @@ 6 6 **RS485-LN – RS485 to LoRaWAN Converter User Manual** 7 7 8 8 9 - 10 - 11 11 **Table of Contents:** 12 12 13 -{{toc/}} 14 14 15 15 16 16 17 17 18 - 19 - 20 - 21 21 = 1.Introduction = 22 22 23 23 == 1.1 What is RS485-LN RS485 to LoRaWAN Converter == ... ... @@ -80,10 +80,8 @@ 80 80 * Preamble detection. 81 81 * 127 dB Dynamic Range RSSI. 82 82 * Automatic RF Sense and CAD with ultra-fast AFC. 83 -* Packet engine up to 256 bytes with CRC 77 +* Packet engine up to 256 bytes with CRC. 84 84 85 - 86 - 87 87 == 1.3 Features == 88 88 89 89 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -95,8 +95,6 @@ 95 95 * Support Modbus protocol 96 96 * Support Interrupt uplink (Since hardware version v1.2) 97 97 98 - 99 - 100 100 == 1.4 Applications == 101 101 102 102 * Smart Buildings & Home Automation ... ... @@ -106,8 +106,6 @@ 106 106 * Smart Cities 107 107 * Smart Factory 108 108 109 - 110 - 111 111 == 1.5 Firmware Change log == 112 112 113 113 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -171,7 +171,7 @@ 171 171 [[image:1653268227651-549.png||height="592" width="720"]] 172 172 173 173 ((( 174 -The LG308 is already set to connect to [[TTN V3 network >>path: https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:162 +The LG308 is already set to connect to [[TTN V3 network >>path:eu1.cloud.thethings.network/]]. So what we need to now is only configure the TTN V3: 175 175 ))) 176 176 177 177 ((( ... ... @@ -527,10 +527,8 @@ 527 527 528 528 === 3.5.3 Sensor related commands === 529 529 530 -(% class="wikigeneratedid" id="H" %) 531 - 518 +==== ==== 532 532 533 - 534 534 ==== **RS485 Debug Command** ==== 535 535 536 536 This command is used to configure the RS485 devices; they won’t be used during sampling. ... ... @@ -863,8 +863,6 @@ 863 863 |**RST**|(% style="width:1420px" %)Reboot RS485 864 864 |**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#upgrade_image]] 865 865 866 - 867 - 868 868 == 3.8 LEDs == 869 869 870 870 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -983,23 +983,17 @@ 983 983 984 984 **Step3: **Open flashloader; choose the correct COM port to update. 985 985 986 -(% style="color: blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.970 +(% style="color:#037691" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 987 987 972 +[[image:image-20220602102605-1.png]] 988 988 989 -[[image:image-20220602175818-12.png]] 990 990 975 +[[image:image-20220602102637-2.png]] 991 991 992 -[[image:image-20220602175848-13.png]] 993 993 978 +[[image:image-20220602102715-3.png]] 994 994 995 -[[image:image-20220602175912-14.png]] 996 996 997 - 998 -**Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 999 - 1000 -[[image:image-20220602175638-10.png]] 1001 - 1002 - 1003 1003 == 6.2 How to change the LoRa Frequency Bands/Region? == 1004 1004 1005 1005 User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download. ... ... @@ -1019,6 +1019,7 @@ 1019 1019 1020 1020 = 7. Trouble Shooting = 1021 1021 1000 + 1022 1022 == 7.1 Downlink doesn’t work, how to solve it? == 1023 1023 1024 1024 Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]] ... ... @@ -1031,7 +1031,7 @@ 1031 1031 1032 1032 = 8. Order Info = 1033 1033 1034 -(% style="color:blue" %)**Part Number: RS485-L N-XXX**1013 +(% style="color:blue" %)**Part Number: RS485-BL-XXX** 1035 1035 1036 1036 (% style="color:blue" %)**XXX:** 1037 1037 ... ... @@ -1046,48 +1046,5 @@ 1046 1046 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1047 1047 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1048 1048 1049 -= 9.Packing Info = 1050 - 1051 - 1052 -**Package Includes**: 1053 - 1054 -* RS485-LN x 1 1055 -* Stick Antenna for LoRa RF part x 1 1056 -* Program cable x 1 1057 - 1058 -**Dimension and weight**: 1059 - 1060 -* Device Size: 13.5 x 7 x 3 cm 1061 -* Device Weight: 105g 1062 -* Package Size / pcs : 14.5 x 8 x 5 cm 1063 -* Weight / pcs : 170g 1064 - 1065 -= 10. FCC Caution for RS485LN-US915 = 1066 - 1067 -Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 1068 - 1069 -This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 1070 - 1071 - 1072 -**IMPORTANT NOTE:** 1073 - 1074 -**Note: **This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1075 - 1076 -—Reorient or relocate the receiving antenna. 1077 - 1078 -—Increase the separation between the equipment and receiver. 1079 - 1080 -—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 1081 - 1082 -—Consult the dealer or an experienced radio/TV technician for help. 1083 - 1084 - 1085 -**FCC Radiation Exposure Statement:** 1086 - 1087 -This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.This equipment should be installed and operated with minimum distance 20cm between the radiator& your body. 1088 - 1089 - 1090 -= 11. Support = 1091 - 1092 -* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1093 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]. 1028 +(% class="wikigeneratedid" %) 1029 +
- image-20220602175638-10.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -85.5 KB - Content
- image-20220602175743-11.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -85.5 KB - Content
- image-20220602175818-12.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -102.5 KB - Content
- image-20220602175848-13.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -250.9 KB - Content
- image-20220602175912-14.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -176.1 KB - Content