... ... @@ -501,33 +501,35 @@
501 501  
502 502  == 3.4 Uplink Payload ==
503 503  
504 -(% border="1" style="background-color:#4bacc6; color:white; width:734px" %)
505 -|**Size(bytes)**|(% style="width:120px" %)**2**|(% style="width:116px" %)**1**|(% style="width:386px" %)**Length depends on the return from the commands**
506 -|Value|(% style="width:120px" %)(((
507 -Battery(mV)
508 508  
509 -&
505 +[[image:image-20220606110929-1.png]]
510 510  
511 -Interrupt _Flag
512 -)))|(% style="width:116px" %)(((
513 -PAYLOAD_VER
514 -
515 -
516 -)))|(% style="width:386px" %)If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server.
517 -
518 518  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
519 519  
520 520  
521 521  == 3.5 Configure RS485-BL via AT or Downlink ==
522 522  
512 +(((
523 523  User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands
514 +)))
524 524  
516 +(((
525 525  There are two kinds of Commands:
518 +)))
526 526  
527 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
520 +* (((
521 +(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
522 +)))
528 528  
529 -* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
524 +* (((
525 +(% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
526 +)))
530 530  
528 +(((
529 +
530 +)))
531 +
532 +
531 531  === 3.5.1 Common Commands ===
532 532  
533 533  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -546,82 +546,159 @@
546 546  
547 547  
548 548  
551 +
549 549  ==== **RS485 Debug Command** ====
550 550  
554 +(((
551 551  This command is used to configure the RS485 devices; they won’t be used during sampling.
556 +)))
552 552  
553 -* **AT Command**
558 +* (((
559 +**AT Command**
560 +)))
554 554  
555 555  (% class="box infomessage" %)
556 556  (((
564 +(((
557 557  **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
558 558  )))
567 +)))
559 559  
569 +(((
560 560  m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
571 +)))
561 561  
562 -* **Downlink Payload**
573 +* (((
574 +**Downlink Payload**
575 +)))
563 563  
577 +(((
564 564  Format: A8 MM NN XX XX XX XX YY
579 +)))
565 565  
581 +(((
566 566  Where:
583 +)))
567 567  
568 -* MM: 1: add CRC-16/MODBUS ; 0: no CRC
569 -* NN: The length of RS485 command
570 -* XX XX XX XX: RS485 command total NN bytes
571 -* YY: How many bytes will be uplink from the return of this RS485 command,
572 -** if YY=0, RS485-LN will execute the downlink command without uplink;
573 -** if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200
574 -** if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200.
585 +* (((
586 +MM: 1: add CRC-16/MODBUS ; 0: no CRC
587 +)))
588 +* (((
589 +NN: The length of RS485 command
590 +)))
591 +* (((
592 +XX XX XX XX: RS485 command total NN bytes
593 +)))
594 +* (((
595 +(((
596 +YY: How many bytes will be uplink from the return of this RS485 command,
597 +)))
575 575  
599 +* (((
600 +if YY=0, RS485-LN will execute the downlink command without uplink;
601 +)))
602 +* (((
603 +if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200
604 +)))
605 +* (((
606 +if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200.
607 +)))
608 +)))
609 +
610 +(((
576 576  **Example 1** ~-~-> Configure without ask for uplink (YY=0)
612 +)))
577 577  
614 +(((
578 578  To connect a Modbus Alarm with below commands.
616 +)))
579 579  
580 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
618 +* (((
619 +The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
620 +)))
581 581  
582 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
622 +* (((
623 +The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
624 +)))
583 583  
626 +(((
584 584  So if user want to use downlink command to control to RS485 Alarm, he can use:
628 +)))
585 585  
630 +(((
586 586  (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm
632 +)))
587 587  
634 +(((
588 588  (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm
636 +)))
589 589  
638 +(((
590 590  A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
640 +)))
591 591  
642 +(((
643 +
644 +)))
592 592  
646 +(((
593 593  **Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
648 +)))
594 594  
650 +(((
595 595  User in IoT server send a downlink command: (% style="color:#4f81bd" %)**A8 01 06 0A 08 00 04 00 01 YY**
652 +)))
596 596  
654 +(((
655 +
656 +)))
597 597  
658 +(((
598 598  RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:
660 +)))
599 599  
662 +(((
600 600   **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
664 +)))
601 601  
666 +(((
602 602   [[image:1654159460680-153.png]]
668 +)))
603 603  
604 604  
605 605  
606 606  ==== **Set Payload version** ====
607 607  
674 +(((
608 608  This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
676 +)))
609 609  
610 -* **AT Command:**
678 +* (((
679 +**AT Command:**
680 +)))
611 611  
612 612  (% class="box infomessage" %)
613 613  (((
684 +(((
614 614  **AT+PAYVER: Set PAYVER field = 1**
615 615  )))
687 +)))
616 616  
617 -* **Downlink Payload:**
689 +* (((
690 +**Downlink Payload:**
691 +)))
618 618  
693 +(((
619 619  **0xAE 01**  ~-~-> Set PAYVER field =  0x01
695 +)))
620 620  
697 +(((
621 621  **0xAE 0F**   ~-~-> Set PAYVER field =  0x0F
699 +)))
622 622  
623 623  
624 624  
703 +
625 625  ==== **Set RS485 Sampling Commands** ====
626 626  
627 627  AT+COMMANDx or AT+DATACUTx