<
From version < 57.48 >
edited by Xiaoling
on 2022/06/06 11:01
To version < 57.35 >
edited by Xiaoling
on 2022/06/06 09:32
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,5 @@
1 1  (% style="text-align:center" %)
2 -[[image:1653266934636-343.png||height="385" width="385"]]
2 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653266934636-343.png?width=385&height=385&rev=1.1||alt="1653266934636-343.png" height="385" width="385"]]
3 3  
4 4  
5 5  
... ... @@ -10,7 +10,59 @@
10 10  
11 11  **Table of Contents:**
12 12  
13 -{{toc/}}
13 +* [[1.Introduction>>path:#H1.Introduction]]
14 +** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>path:#H1.1A0WhatisRS485-LNRS485toLoRaWANConverter]]
15 +** [[1.2 Specifications>>path:#H1.2A0Specifications]]
16 +** [[1.3 Features>>path:#H1.3Features]]
17 +** [[1.4 Applications>>path:#H1.4A0Applications]]
18 +** [[1.5 Firmware Change log>>path:#H1.5A0FirmwareChangelog]]
19 +** [[1.6 Hardware Change log>>path:#H1.6HardwareChangelog]]
20 +* [[2. Power ON Device>>path:#H2.PowerONDevice]]
21 +* [[3. Operation Mode>>path:#H3.A0OperationMode]]
22 +** [[3.1 How it works?>>path:#H3.1Howitworks3F]]
23 +** [[3.2 Example to join LoRaWAN network>>path:#H3.2ExampletojoinLoRaWANnetwork]]
24 +** [[3.3 Configure Commands to read data>>path:#H3.3ConfigureCommandstoreaddata]]
25 +*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>path:#H3.3.1onfigureUARTsettingsforRS485orTTLcommunication]]
26 +*** [[3.3.2 Configure sensors>>path:#H3.3.2Configuresensors]]
27 +*** [[3.3.3 Configure read commands for each sampling>>path:#H3.3.3Configurereadcommandsforeachsampling]]
28 +*** [[3.3.4 Compose the uplink payload>>path:#H3.3.4Composetheuplinkpayload]]
29 +*** [[3.3.5 Uplink on demand>>path:#H3.3.5Uplinkondemand]]
30 +*** [[3.3.6 Uplink on Interrupt>>path:#H3.3.6UplinkonInterrupt]]
31 +** [[3.4 Uplink Payload>>path:#H3.4UplinkPayload]]
32 +** [[3.5 Configure RS485-BL via AT or Downlink>>path:#H3.5ConfigureRS485-BLviaATorDownlink]]
33 +*** [[3.5.1 Common Commands>>path:#H3.5.1CommonCommands]]
34 +*** [[3.5.2 Sensor related commands>>path:#H3.5.2Sensorrelatedcommands]]
35 +*** [[3.5.3 Sensor related commands>>path:#H3.5.3A0Sensorrelatedcommands]]
36 +**** [[RS485 Debug Command>>path:#HRS485DebugCommand]]
37 +**** [[Set Payload version>>path:#HSetPayloadversion]]
38 +**** [[Set RS485 Sampling Commands>>path:#HSetRS485SamplingCommands]]
39 +**** [[Fast command to handle MODBUS device>>path:#HFastcommandtohandleMODBUSdevice]]
40 +**** [[RS485 command timeout>>path:#HRS485commandtimeout]]
41 +**** [[Uplink payload mode>>path:#HUplinkpayloadmode]]
42 +**** [[Manually trigger an Uplink>>path:#HManuallytriggeranUplink]]
43 +**** [[Clear RS485 Command>>path:#HClearRS485Command]]
44 +**** [[Set Serial Communication Parameters>>path:#HSetSerialCommunicationParameters]]
45 +** [[3.6 Listening mode for RS485 network>>path:#H3.6A0ListeningmodeforRS485network]]
46 +** [[3.7 Buttons>>path:#H3.7Buttons]]
47 +** [[3.8 LEDs>>path:#H3.8LEDs]]
48 +* [[4. Case Study>>path:#H4.CaseStudy]]
49 +* [[5. Use AT Command>>path:#H5.UseATCommand]]
50 +** [[5.1 Access AT Command>>path:#H5.1AccessATCommand]]
51 +** [[5.2 Common AT Command Sequence>>path:#H5.2CommonATCommandSequence]]
52 +*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>path:#H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829]]
53 +*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>path:#H5.5.2Single-channelABPmode28UsewithLG012FLG0229]]
54 +* [[6. FAQ>>path:#H6.FAQ]]
55 +** [[6.1 How to upgrade the image?>>path:#H6.1Howtoupgradetheimage3F]]
56 +** [[6.2 How to change the LoRa Frequency Bands/Region?>>path:#H6.2HowtochangetheLoRaFrequencyBands2FRegion3F]]
57 +** [[6.3 How many RS485-Slave can RS485-BL connects?>>path:#H6.3HowmanyRS485-SlavecanRS485-BLconnects3F]]
58 +** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>path:#H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F]]
59 +* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
60 +** [[7.1 Downlink doesn’t work, how to solve it?>>path:#H7.1Downlinkdoesn2019twork2Chowtosolveit3F]]
61 +** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>path:#H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F]]
62 +* [[8. Order Info>>path:#H8.OrderInfo]]
63 +* [[9.Packing Info>>path:#H9.PackingInfo]]
64 +* [[10. FCC Caution for RS485LN-US915>>path:#H10.FCCCautionforRS485LN-US915]]
65 +* [[11. Support>>path:#H11.Support]]
14 14  
15 15  
16 16  
... ... @@ -24,35 +24,25 @@
24 24  
25 25  (((
26 26  (((
27 -(((
28 28  The Dragino RS485-LN is a (% style="color:blue" %)**RS485 to LoRaWAN Converter**(%%). It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost.
29 29  )))
30 -)))
31 31  
32 32  (((
33 -(((
34 34  RS485-LN allows user to (% style="color:blue" %)**monitor / control RS485 devices**(%%) and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on.
35 35  )))
36 -)))
37 37  
38 38  (((
39 -(((
40 40  (% style="color:blue" %)**For data uplink**(%%), RS485-LN sends user-defined commands to RS485 devices and gets the return from the RS485 devices. RS485-LN will process these returns according to user-define rules to get the final payload and upload to LoRaWAN server.
41 41  )))
42 -)))
43 43  
44 44  (((
45 -(((
46 46  (% style="color:blue" %)**For data downlink**(%%), RS485-LN runs in LoRaWAN Class C. When there downlink commands from LoRaWAN server, RS485-LN will forward the commands from LoRaWAN server to RS485 devices.
47 -)))
48 48  
49 -(((
50 50  (% style="color:blue" %)**Demo Dashboard for RS485-LN**(%%) connect to two energy meters: [[https:~~/~~/app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a>>url:https://app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a]]
51 51  )))
52 52  )))
53 -)))
54 54  
55 -[[image:1653267211009-519.png||height="419" width="724"]]
97 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653267211009-519.png?width=724&height=419&rev=1.1||alt="1653267211009-519.png" height="419" width="724"]]
56 56  
57 57  
58 58  == 1.2 Specifications ==
... ... @@ -103,7 +103,6 @@
103 103  * Support Modbus protocol
104 104  * Support Interrupt uplink (Since hardware version v1.2)
105 105  
106 -
107 107  == 1.4 Applications ==
108 108  
109 109  * Smart Buildings & Home Automation
... ... @@ -113,7 +113,6 @@
113 113  * Smart Cities
114 114  * Smart Factory
115 115  
116 -
117 117  == 1.5 Firmware Change log ==
118 118  
119 119  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -123,13 +123,9 @@
123 123  
124 124  (((
125 125  (((
126 -(((
127 127  v1.2: Add External Interrupt Pin.
128 -)))
129 129  
130 -(((
131 131  v1.0: Release
132 -)))
133 133  
134 134  
135 135  )))
... ... @@ -147,7 +147,7 @@
147 147  Once there is power, the RS485-LN will be on.
148 148  )))
149 149  
150 -[[image:1653268091319-405.png]]
186 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268091319-405.png?rev=1.1||alt="1653268091319-405.png"]]
151 151  
152 152  
153 153  )))
... ... @@ -157,9 +157,7 @@
157 157  == 3.1 How it works? ==
158 158  
159 159  (((
160 -(((
161 161  The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA.
162 -)))
163 163  
164 164  
165 165  )))
... ... @@ -168,7 +168,7 @@
168 168  
169 169  Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
170 170  
171 -[[image:1653268155545-638.png||height="334" width="724"]]
205 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268155545-638.png?width=724&height=334&rev=1.1||alt="1653268155545-638.png" height="334" width="724"]]
172 172  
173 173  
174 174  (((
... ... @@ -180,10 +180,10 @@
180 180  485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively.
181 181  )))
182 182  
183 -[[image:1653268227651-549.png||height="592" width="720"]]
217 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268227651-549.png?width=720&height=592&rev=1.1||alt="1653268227651-549.png" height="592" width="720"]]
184 184  
185 185  (((
186 -The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:
220 +The LG308 is already set to connect to (% class="wikiinternallink" %)[[TTN V3 network >>url:https://www.thethingsnetwork.org/]](%%). So what we need to now is only configure the TTN V3:
187 187  )))
188 188  
189 189  (((
... ... @@ -195,7 +195,7 @@
195 195  )))
196 196  )))
197 197  
198 -[[image:1652953462722-299.png]]
232 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953462722-299.png?rev=1.1||alt="1652953462722-299.png"]]
199 199  
200 200  (((
201 201  (((
... ... @@ -207,21 +207,21 @@
207 207  )))
208 208  )))
209 209  
210 -[[image:image-20220519174512-1.png]]
244 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-1.png?rev=1.1||alt="image-20220519174512-1.png"]]
211 211  
212 -[[image:image-20220519174512-2.png||height="323" width="720"]]
246 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-2.png?width=720&height=323&rev=1.1||alt="image-20220519174512-2.png" height="323" width="720"]]
213 213  
214 -[[image:image-20220519174512-3.png||height="556" width="724"]]
248 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-3.png?width=724&height=556&rev=1.1||alt="image-20220519174512-3.png" height="556" width="724"]]
215 215  
216 -[[image:image-20220519174512-4.png]]
250 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-4.png?rev=1.1||alt="image-20220519174512-4.png"]]
217 217  
218 218  You can also choose to create the device manually.
219 219  
220 -[[image:1652953542269-423.png||height="710" width="723"]]
254 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953542269-423.png?width=723&height=710&rev=1.1||alt="1652953542269-423.png" height="710" width="723"]]
221 221  
222 222  Add APP KEY and DEV EUI
223 223  
224 -[[image:1652953553383-907.png||height="514" width="724"]]
258 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953553383-907.png?width=724&height=514&rev=1.1||alt="1652953553383-907.png" height="514" width="724"]]
225 225  
226 226  
227 227  (((
... ... @@ -228,7 +228,7 @@
228 228  **Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
229 229  )))
230 230  
231 -[[image:1652953568895-172.png||height="232" width="724"]]
265 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953568895-172.png?width=724&height=232&rev=1.1||alt="1652953568895-172.png" height="232" width="724"]]
232 232  
233 233  
234 234  == 3.3 Configure Commands to read data ==
... ... @@ -235,7 +235,7 @@
235 235  
236 236  (((
237 237  (((
238 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
272 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
239 239  )))
240 240  
241 241  (((
... ... @@ -249,19 +249,19 @@
249 249  
250 250  To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
251 251  
252 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
253 -|=(% style="width: 110px;" %)(((
286 +(% border="1" style="background-color:#ffffcc; color:green; width:782px" %)
287 +|(% style="width:128px" %)(((
254 254  **AT Commands**
255 -)))|=(% style="width: 190px;" %)(((
289 +)))|(% style="width:305px" %)(((
256 256  **Description**
257 -)))|=(% style="width: 190px;" %)(((
291 +)))|(% style="width:346px" %)(((
258 258  **Example**
259 259  )))
260 -|(% style="width:110px" %)(((
294 +|(% style="width:128px" %)(((
261 261  AT+BAUDR
262 -)))|(% style="width:190px" %)(((
296 +)))|(% style="width:305px" %)(((
263 263  Set the baud rate (for RS485 connection). Default Value is: 9600.
264 -)))|(% style="width:190px" %)(((
298 +)))|(% style="width:346px" %)(((
265 265  (((
266 266  AT+BAUDR=9600
267 267  )))
... ... @@ -270,11 +270,11 @@
270 270  Options: (1200,2400,4800,14400,19200,115200)
271 271  )))
272 272  )))
273 -|(% style="width:110px" %)(((
307 +|(% style="width:128px" %)(((
274 274  AT+PARITY
275 -)))|(% style="width:190px" %)(((
309 +)))|(% style="width:305px" %)(((
276 276  Set UART parity (for RS485 connection)
277 -)))|(% style="width:190px" %)(((
311 +)))|(% style="width:346px" %)(((
278 278  (((
279 279  AT+PARITY=0
280 280  )))
... ... @@ -283,9 +283,9 @@
283 283  Option: 0: no parity, 1: odd parity, 2: even parity
284 284  )))
285 285  )))
286 -|(% style="width:110px" %)(((
320 +|(% style="width:128px" %)(((
287 287  AT+STOPBIT
288 -)))|(% style="width:190px" %)(((
322 +)))|(% style="width:305px" %)(((
289 289  (((
290 290  Set serial stopbit (for RS485 connection)
291 291  )))
... ... @@ -293,7 +293,7 @@
293 293  (((
294 294  
295 295  )))
296 -)))|(% style="width:190px" %)(((
330 +)))|(% style="width:346px" %)(((
297 297  (((
298 298  AT+STOPBIT=0 for 1bit
299 299  )))
... ... @@ -307,8 +307,6 @@
307 307  )))
308 308  )))
309 309  
310 -
311 -
312 312  === 3.3.2 Configure sensors ===
313 313  
314 314  (((
... ... @@ -317,15 +317,15 @@
317 317  )))
318 318  )))
319 319  
320 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
321 -|=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
322 -|AT+CFGDEV|(% style="width:110px" %)(((
352 +(% border="1" style="background-color:#ffffcc; color:green; width:806px" %)
353 +|**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example**
354 +|AT+CFGDEV|(% style="width:418px" %)(((
323 323  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
324 324  
325 325  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
326 326  
327 327  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
328 -)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
360 +)))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
329 329  
330 330  === 3.3.3 Configure read commands for each sampling ===
331 331  
... ... @@ -372,8 +372,8 @@
372 372  
373 373  **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
374 374  
375 -(% border="1" style="background-color:#4bacc6; color:white; width:510px" %)
376 -|(% style="width:510px" %)(((
407 +(% border="1" style="background-color:#4bacc6; color:white; width:725px" %)
408 +|(% style="width:722px" %)(((
377 377  **AT+DATACUTx=a,b,c**
378 378  
379 379  * **a: length for the return of AT+COMMAND**
... ... @@ -385,17 +385,17 @@
385 385  
386 386  * Grab bytes:
387 387  
388 -[[image:image-20220602153621-1.png]]
420 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-1.png?rev=1.1||alt="image-20220602153621-1.png"]]
389 389  
390 390  
391 391  * Grab a section.
392 392  
393 -[[image:image-20220602153621-2.png]]
425 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-2.png?rev=1.1||alt="image-20220602153621-2.png"]]
394 394  
395 395  
396 396  * Grab different sections.
397 397  
398 -[[image:image-20220602153621-3.png]]
430 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-3.png?rev=1.1||alt="image-20220602153621-3.png"]]
399 399  
400 400  
401 401  )))
... ... @@ -430,7 +430,7 @@
430 430  Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
431 431  )))
432 432  
433 -[[image:1653269759169-150.png||height="513" width="716"]]
465 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653269759169-150.png?width=716&height=513&rev=1.1||alt="1653269759169-150.png" height="513" width="716"]]
434 434  
435 435  
436 436  (% style="color:#037691" %)**Examples: AT+DATAUP=1**
... ... @@ -448,7 +448,7 @@
448 448  1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
449 449  1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes
450 450  
451 -[[image:image-20220602155039-4.png]]
483 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602155039-4.png?rev=1.1||alt="image-20220602155039-4.png"]]
452 452  
453 453  
454 454  So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA
... ... @@ -473,7 +473,7 @@
473 473  
474 474  Below are the uplink payloads:
475 475  
476 -[[image:1654157178836-407.png]]
508 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157178836-407.png?rev=1.1||alt="1654157178836-407.png"]]
477 477  
478 478  
479 479  === 3.3.5 Uplink on demand ===
... ... @@ -492,7 +492,7 @@
492 492  
493 493  RS485-LN support external Interrupt uplink since hardware v1.2 release.
494 494  
495 -[[image:1654157342174-798.png]]
527 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157342174-798.png?rev=1.1||alt="1654157342174-798.png"]]
496 496  
497 497  Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet.
498 498  
... ... @@ -522,13 +522,13 @@
522 522  
523 523  There are two kinds of Commands:
524 524  
525 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
557 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
526 526  
527 527  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
528 528  
529 529  === 3.5.1 Common Commands ===
530 530  
531 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
563 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
532 532  
533 533  
534 534  === 3.5.2 Sensor related commands ===
... ... @@ -535,7 +535,7 @@
535 535  
536 536  Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server.
537 537  
538 -[[image:image-20220602163333-5.png||height="263" width="1160"]]
570 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602163333-5.png?width=1160&height=263&rev=1.1||alt="image-20220602163333-5.png" height="263" width="1160"]]
539 539  
540 540  The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable)
541 541  
... ... @@ -597,7 +597,7 @@
597 597  
598 598   **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
599 599  
600 - [[image:1654159460680-153.png]]
632 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654159460680-153.png?rev=1.1||alt="1654159460680-153.png"]]
601 601  
602 602  
603 603  
... ... @@ -624,7 +624,7 @@
624 624  
625 625  AT+COMMANDx or AT+DATACUTx
626 626  
627 -These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
659 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#H3.3.3Configurereadcommandsforeachsampling]].
628 628  
629 629  
630 630  * **AT Command:**
... ... @@ -681,9 +681,9 @@
681 681  * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
682 682  * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
683 683  
684 -[[image:image-20220602165351-6.png]]
716 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-6.png?rev=1.1||alt="image-20220602165351-6.png"]]
685 685  
686 -[[image:image-20220602165351-7.png]]
718 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-7.png?rev=1.1||alt="image-20220602165351-7.png"]]
687 687  
688 688  
689 689  
... ... @@ -721,7 +721,7 @@
721 721  
722 722  Define to use one uplink or multiple uplinks for the sampling.
723 723  
724 -The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
756 +The use of this command please see: [[Compose Uplink payload>>path:#H3.3.4Composetheuplinkpayload]]
725 725  
726 726  * **AT Command:**
727 727  
... ... @@ -750,7 +750,7 @@
750 750  
751 751  * **AT Command:**
752 752  
753 -No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same.
785 +No AT Command for this, user can press the [[ACT button>>path:#H3.7Buttons]] for 1 second for the same.
754 754  
755 755  
756 756  * **Downlink Payload:**
... ... @@ -774,7 +774,7 @@
774 774  
775 775  The uplink screen shot is:
776 776  
777 -[[image:1654160691922-496.png]]
809 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654160691922-496.png?rev=1.1||alt="1654160691922-496.png"]]
778 778  
779 779  
780 780  * **Downlink Payload:**
... ... @@ -831,7 +831,7 @@
831 831  
832 832  RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN.
833 833  
834 -[[image:image-20220602171200-8.png||height="567" width="1007"]]
866 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-8.png?width=1007&height=567&rev=1.1||alt="image-20220602171200-8.png" height="567" width="1007"]]
835 835  
836 836  To enable the listening mode, use can run the command AT+RXMODE.
837 837  
... ... @@ -860,7 +860,7 @@
860 860  
861 861  RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b  (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33
862 862  
863 -[[image:image-20220602171200-9.png]]
895 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-9.png?rev=1.1||alt="image-20220602171200-9.png"]]
864 864  
865 865  
866 866  (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
... ... @@ -873,7 +873,7 @@
873 873  |=**Button**|=(% style="width: 1420px;" %)**Feature**
874 874  |**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
875 875  |**RST**|(% style="width:1420px" %)Reboot RS485
876 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
908 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#H6.1Howtoupgradetheimage3F]]
877 877  
878 878  == 3.8 LEDs ==
879 879  
... ... @@ -884,7 +884,7 @@
884 884  
885 885  = 4. Case Study =
886 886  
887 -User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
919 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>path:/xwiki/bin/view/Main/Application%20Note%20%3A%20Communicate%20with%20Different%20Sensors%20-----%20RS485-LN%20%20RS485-BL/]]
888 888  
889 889  
890 890  = 5. Use AT Command =
... ... @@ -893,15 +893,15 @@
893 893  
894 894  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
895 895  
896 -[[image:1654162355560-817.png]]
928 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162355560-817.png?rev=1.1||alt="1654162355560-817.png"]]
897 897  
898 898  
899 899  In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
900 900  
901 -[[image:1654162368066-342.png]]
933 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162368066-342.png?rev=1.1||alt="1654162368066-342.png"]]
902 902  
903 903  
904 -More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
936 +More detail AT Command manual can be found at [[AT Command Manual>>url:https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
905 905  
906 906  
907 907  == 5.2 Common AT Command Sequence ==
... ... @@ -970,7 +970,7 @@
970 970  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
971 971  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
972 972  
973 -[[image:1654162478620-421.png]]
1005 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162478620-421.png?rev=1.1||alt="1654162478620-421.png"]]
974 974  
975 975  
976 976  = 6. FAQ =
... ... @@ -985,7 +985,7 @@
985 985  
986 986  Below shows the hardware connection for how to upload an image to RS485-LN:
987 987  
988 -[[image:1654162535040-878.png]]
1020 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162535040-878.png?rev=1.1||alt="1654162535040-878.png"]]
989 989  
990 990  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
991 991  
... ... @@ -998,28 +998,28 @@
998 998  )))
999 999  
1000 1000  
1001 -[[image:image-20220602175818-12.png]]
1033 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175818-12.png?rev=1.1||alt="image-20220602175818-12.png"]]
1002 1002  
1003 1003  
1004 -[[image:image-20220602175848-13.png]]
1036 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175848-13.png?rev=1.1||alt="image-20220602175848-13.png"]]
1005 1005  
1006 1006  
1007 -[[image:image-20220602175912-14.png]]
1039 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175912-14.png?rev=1.1||alt="image-20220602175912-14.png"]]
1008 1008  
1009 1009  
1010 1010  **Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1011 1011  
1012 -[[image:image-20220602175638-10.png]]
1044 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175638-10.png?rev=1.1||alt="image-20220602175638-10.png"]]
1013 1013  
1014 1014  
1015 1015  == 6.2 How to change the LoRa Frequency Bands/Region? ==
1016 1016  
1017 -User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
1049 +User can follow the introduction for [[how to upgrade image>>path:#H6.1Howtoupgradetheimage3F]]. When download the images, choose the required image file for download.
1018 1018  
1019 1019  
1020 1020  == 6.3 How many RS485-Slave can RS485-BL connects? ==
1021 1021  
1022 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1054 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#H3.3.3Configurereadcommandsforeachsampling]].
1023 1023  
1024 1024  
1025 1025  == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==
... ... @@ -1026,7 +1026,7 @@
1026 1026  
1027 1027  When user need to use with ChirpStack or TTI. Please set AT+RPL=4.
1028 1028  
1029 -Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]
1061 +Detail info check this link: [[Set Packet Receiving Response Level>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.23SetPacketReceivingResponseLevel]]
1030 1030  
1031 1031  
1032 1032  = 7. Trouble Shooting =
... ... @@ -1033,12 +1033,12 @@
1033 1033  
1034 1034  == 7.1 Downlink doesn’t work, how to solve it? ==
1035 1035  
1036 -Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]]
1068 +Please see this link for debug: [[LoRaWAN Communication Debug>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/]]
1037 1037  
1038 1038  
1039 1039  == 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? ==
1040 1040  
1041 -It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1073 +It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]]
1042 1042  
1043 1043  
1044 1044  = 8. Order Info =
... ... @@ -1058,7 +1058,6 @@
1058 1058  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1059 1059  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1060 1060  
1061 -
1062 1062  = 9.Packing Info =
1063 1063  
1064 1064  
... ... @@ -1075,63 +1075,32 @@
1075 1075  * Package Size / pcs : 14.5 x 8 x 5 cm
1076 1076  * Weight / pcs : 170g
1077 1077  
1078 -
1079 1079  = 10. FCC Caution for RS485LN-US915 =
1080 1080  
1081 -(((
1082 1082  Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
1083 -)))
1084 1084  
1085 -(((
1086 1086  This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
1087 -)))
1088 1088  
1089 -(((
1090 -
1091 -)))
1092 1092  
1093 -(((
1094 1094  **IMPORTANT NOTE:**
1095 -)))
1096 1096  
1097 -(((
1098 1098  **Note: **This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1099 -)))
1100 1100  
1101 -(((
1102 1102  —Reorient or relocate the receiving antenna.
1103 -)))
1104 1104  
1105 -(((
1106 1106  —Increase the separation between the equipment and receiver.
1107 -)))
1108 1108  
1109 -(((
1110 1110  —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
1111 -)))
1112 1112  
1113 -(((
1114 1114  —Consult the dealer or an experienced radio/TV technician for help.
1115 -)))
1116 1116  
1117 -(((
1118 -
1119 -)))
1120 1120  
1121 -(((
1122 1122  **FCC Radiation Exposure Statement:**
1123 -)))
1124 1124  
1125 -(((
1126 1126  This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.
1127 -)))
1128 1128  
1129 1129  
1130 1130  = 11. Support =
1131 1131  
1132 -* (((
1133 -Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1134 -)))
1135 -* (((
1136 -Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
1137 -)))
1136 +* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1137 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0