Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Change comment:
Uploaded new attachment "image-20220824145428-2.png", version {1}
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -RS485-LN – RS485 to LoRaWAN Converter 1 +RS485-LN – RS485 to LoRaWAN Converter User Manual - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -1,23 +1,33 @@ 1 -(% style="text-align:center" %) 2 -[[image:1653266934636-343.png||height="385" width="385"]] 1 +(% aria-label="1653266934636-343.png image widget" contenteditable="false" role="region" tabindex="-1" %) 2 +((( 3 +(% data-widget="image" style="text-align:center" %) 4 +[[image:1653266934636-343.png||height="385" width="385"]](% title="Click and drag to resize" %) 3 3 6 +(% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||height="15" role="presentation" title="Click and drag to move" width="15"]] 7 +))) 4 4 5 5 6 -**RS485-LN – RS485 to LoRaWAN Converter User Manual** 7 7 8 8 9 9 10 10 14 + 11 11 **Table of Contents:** 12 12 13 13 {{toc/}} 14 14 15 15 20 +(% aria-label="macro:toc widget" contenteditable="false" role="region" tabindex="-1" %) 21 +((( 22 +(% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||height="15" role="presentation" title="Click and drag to move" width="15"]] 23 +))) 16 16 17 17 18 18 19 19 20 20 29 + 30 + 21 21 = 1.Introduction = 22 22 23 23 == 1.1 What is RS485-LN RS485 to LoRaWAN Converter == ... ... @@ -25,6 +25,8 @@ 25 25 ((( 26 26 ((( 27 27 ((( 38 + 39 + 28 28 The Dragino RS485-LN is a (% style="color:blue" %)**RS485 to LoRaWAN Converter**(%%). It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost. 29 29 ))) 30 30 ))) ... ... @@ -48,17 +48,20 @@ 48 48 49 49 ((( 50 50 (% style="color:blue" %)**Demo Dashboard for RS485-LN**(%%) connect to two energy meters: [[https:~~/~~/app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a>>url:https://app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a]] 63 + 64 + 51 51 ))) 52 52 ))) 53 53 ))) 54 54 55 -[[image:1653267211009-519.png||height="419" width="724"]] 69 +(% aria-label="1653267211009-519.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653267211009-519.png||data-widget="image" height="419" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 56 56 57 57 72 + 58 58 == 1.2 Specifications == 59 59 60 60 61 -**Hardware System:** 76 +(% style="color:#037691" %)**Hardware System:** 62 62 63 63 * STM32L072CZT6 MCU 64 64 * SX1276/78 Wireless Chip ... ... @@ -66,13 +66,15 @@ 66 66 ** Idle: 32mA@12v 67 67 ** 20dB Transmit: 65mA@12v 68 68 69 -**Interface for Model:** 70 70 85 +(% style="color:#037691" %)**Interface for Model:** 86 + 71 71 * RS485 72 72 * Power Input 7~~ 24V DC. 73 73 74 -**LoRa Spec:** 75 75 91 +(% style="color:#037691" %)**LoRa Spec:** 92 + 76 76 * Frequency Range: 77 77 ** Band 1 (HF): 862 ~~ 1020 Mhz 78 78 ** Band 2 (LF): 410 ~~ 528 Mhz ... ... @@ -92,8 +92,11 @@ 92 92 * Automatic RF Sense and CAD with ultra-fast AFC. 93 93 * Packet engine up to 256 bytes with CRC 94 94 112 + 113 + 95 95 == 1.3 Features == 96 96 116 + 97 97 * LoRaWAN Class A & Class C protocol (default Class C) 98 98 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864 99 99 * AT Commands to change parameters ... ... @@ -107,6 +107,7 @@ 107 107 108 108 == 1.4 Applications == 109 109 130 + 110 110 * Smart Buildings & Home Automation 111 111 * Logistics and Supply Chain Management 112 112 * Smart Metering ... ... @@ -118,11 +118,14 @@ 118 118 119 119 == 1.5 Firmware Change log == 120 120 142 + 121 121 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] 122 122 123 123 146 + 124 124 == 1.6 Hardware Change log == 125 125 149 + 126 126 ((( 127 127 ((( 128 128 ((( ... ... @@ -133,6 +133,7 @@ 133 133 v1.0: Release 134 134 ))) 135 135 160 + 136 136 137 137 ))) 138 138 ))) ... ... @@ -139,6 +139,7 @@ 139 139 140 140 = 2. Power ON Device = 141 141 167 + 142 142 ((( 143 143 The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below 144 144 ... ... @@ -149,8 +149,9 @@ 149 149 Once there is power, the RS485-LN will be on. 150 150 ))) 151 151 152 -[[image:1653268091319-405.png]] 178 +(% aria-label="1653268091319-405.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653268091319-405.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 153 153 180 + 154 154 155 155 ))) 156 156 ... ... @@ -158,19 +158,22 @@ 158 158 159 159 == 3.1 How it works? == 160 160 188 + 161 161 ((( 162 162 ((( 163 163 The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA. 164 164 ))) 165 165 194 + 166 166 167 167 ))) 168 168 169 169 == 3.2 Example to join LoRaWAN network == 170 170 200 + 171 171 Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 172 172 173 -[[image:1653268155545-638.png||height="334" width="724"]] 203 +(% aria-label="1653268155545-638.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653268155545-638.png||data-widget="image" height="334" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 174 174 175 175 176 176 ((( ... ... @@ -182,14 +182,17 @@ 182 182 485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively. 183 183 ))) 184 184 185 -[[image:1653268227651-549.png||height="592" width="720"]] 215 +(% aria-label="1653268227651-549.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653268227651-549.png||data-widget="image" height="592" width="720"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 186 186 217 + 187 187 ((( 188 188 The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3: 220 + 221 + 189 189 ))) 190 190 191 191 ((( 192 -**Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-LN. 225 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN V3 with the OTAA keys from RS485-LN. 193 193 ))) 194 194 195 195 ((( ... ... @@ -197,8 +197,9 @@ 197 197 ))) 198 198 ))) 199 199 200 -[[image:1652953462722-299.png]] 233 +(% aria-label="1652953462722-299.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1652953462722-299.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 201 201 235 + 202 202 ((( 203 203 ((( 204 204 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot: ... ... @@ -205,50 +205,60 @@ 205 205 ))) 206 206 207 207 ((( 208 -Add APP EUI in the application. 242 +**Add APP EUI in the application.** 209 209 ))) 210 210 ))) 211 211 212 -[[image:image-20220519174512-1.png]] 246 +(% aria-label="image-20220519174512-1.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220519174512-1.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 213 213 214 -[[image:image-20220519174512-2.png||height="323" width="720"]] 248 +(% aria-label="image-20220519174512-2.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220519174512-2.png||data-widget="image" height="323" width="720"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 215 215 216 -[[image:image-20220519174512-3.png||height="556" width="724"]] 250 +(% aria-label="image-20220519174512-3.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220519174512-3.png||data-widget="image" height="556" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 217 217 218 -[[image:image-20220519174512-4.png]] 252 +(% aria-label="image-20220519174512-4.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220519174512-4.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 219 219 220 220 You can also choose to create the device manually. 221 221 222 -[[image:1652953542269-423.png||height="710" width="723"]] 256 +(% aria-label="1652953542269-423.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1652953542269-423.png||data-widget="image" height="710" width="723"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 223 223 224 -Add APP KEY and DEV EUI 225 225 226 -[[image:1652953553383-907.png||height="514" width="724"]] 227 227 260 +**Add APP KEY and DEV EUI** 228 228 262 +(% aria-label="1652953553383-907.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1652953553383-907.png||data-widget="image" height="514" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 263 + 264 + 229 229 ((( 230 -**Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 266 +(% style="color:blue" %)**Step 2**(%%): Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 231 231 ))) 232 232 233 -[[image:1652953568895-172.png||height="232" width="724"]] 269 +(% aria-label="1652953568895-172.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1652953568895-172.png||data-widget="image" height="232" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 234 234 235 235 272 + 236 236 == 3.3 Configure Commands to read data == 237 237 275 + 238 238 ((( 239 239 ((( 240 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 278 +((( 279 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-LNviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 241 241 ))) 281 +))) 242 242 243 243 ((( 244 -(% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 284 +((( 285 +(% style="color:red" %)**Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1** 286 +))) 245 245 288 + 246 246 247 247 ))) 248 248 ))) 249 249 250 -=== 3.3.1 onfigure UART settings for RS485 or TTL communication === 293 +=== 3.3.1 Configure UART settings for RS485 or TTL communication === 251 251 295 + 252 252 To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are: 253 253 254 254 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) ... ... @@ -309,26 +309,40 @@ 309 309 ))) 310 310 ))) 311 311 356 + 357 + 312 312 === 3.3.2 Configure sensors === 313 313 360 + 314 314 ((( 315 315 ((( 316 -Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won’t run during each sampling. 363 +Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won't run during each sampling. 364 + 365 + 317 317 ))) 318 318 ))) 319 319 320 -(% border="1" style="background-color:#ffffcc; color:green; width:510px" %) 321 -|(% style="width:110px" %)**AT Commands**|(% style="width:190px" %)**Description**|(% style="width:190px" %)**Example** 369 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 370 +|=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 322 322 |AT+CFGDEV|(% style="width:110px" %)((( 372 +((( 323 323 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 374 +))) 324 324 376 +((( 325 325 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 378 +))) 326 326 380 +((( 327 327 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 382 +))) 328 328 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 329 329 385 + 386 + 330 330 === 3.3.3 Configure read commands for each sampling === 331 331 389 + 332 332 ((( 333 333 During each sampling, we need confirm what commands we need to send to the RS485 sensors to read data. After the RS485 sensors send back the value, it normally include some bytes and we only need a few from them for a shorten payload. 334 334 ... ... @@ -339,7 +339,7 @@ 339 339 During each sampling, the RS485-LN can support 15 commands to read sensors. And combine the return to one or several uplink payloads. 340 340 341 341 342 -**Each RS485 commands include two parts:** 400 +(% style="color:#037691" %)**Each RS485 commands include two parts:** 343 343 344 344 ~1. What commands RS485-LN will send to the RS485 sensors. There are total 15 commands from **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF**. All commands are of same grammar. 345 345 ... ... @@ -350,15 +350,14 @@ 350 350 351 351 After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**. 352 352 353 - 354 354 Below are examples for the how above AT Commands works. 355 355 356 356 357 -**AT+COMMANDx : **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is: 414 +(% style="color:#037691" %)**AT+COMMANDx **(%%)**: **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is: 358 358 359 359 (% border="1" style="background-color:#4bacc6; color:white; width:499px" %) 360 360 |(% style="width:496px" %)((( 361 -**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 418 +(% style="color:#037691" %)**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 362 362 363 363 **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent** 364 364 ... ... @@ -370,7 +370,7 @@ 370 370 In the RS485-LN, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same. 371 371 372 372 373 -**AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes. 430 +(% style="color:#037691" %)**AT+DATACUTx **(%%)**: **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes. 374 374 375 375 (% border="1" style="background-color:#4bacc6; color:white; width:510px" %) 376 376 |(% style="width:510px" %)((( ... ... @@ -383,25 +383,29 @@ 383 383 384 384 **Examples:** 385 385 386 -* Grab bytes :443 +* (% style="color:#037691" %)**Grab bytes** 387 387 388 -[[image:image-20220602153621-1.png]] 445 +(% aria-label="image-20220602153621-1.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602153621-1.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 389 389 390 390 391 -* Grab a section. 392 392 393 - [[image:image-20220602153621-2.png]]449 +* (% style="color:#037691" %)**Grab a section** 394 394 451 +(% aria-label="image-20220602153621-2.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602153621-2.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 395 395 396 -* Grab different sections. 397 397 398 -[[image:image-20220602153621-3.png]] 399 399 455 +* (% style="color:#037691" %)**Grab different sections** 456 + 457 +(% aria-label="image-20220602153621-3.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602153621-3.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 458 + 459 + 400 400 401 401 ))) 402 402 403 403 === 3.3.4 Compose the uplink payload === 404 404 465 + 405 405 ((( 406 406 Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.** 407 407 ... ... @@ -430,7 +430,7 @@ 430 430 Where PAYVER is defined by AT+PAYVER, below is an example screen shot. 431 431 ))) 432 432 433 -[[image:1653269759169-150.png||height="513" width="716"]] 494 +(% aria-label="1653269759169-150.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653269759169-150.png||data-widget="image" height="513" width="716"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 434 434 435 435 436 436 (% style="color:#037691" %)**Examples: AT+DATAUP=1** ... ... @@ -448,7 +448,7 @@ 448 448 1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) 449 449 1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes 450 450 451 -[[image:image-20220602155039-4.png]] 512 +(% aria-label="image-20220602155039-4.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602155039-4.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 452 452 453 453 454 454 So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA ... ... @@ -460,7 +460,7 @@ 460 460 DATA3=the rest of Valid value of RETURN10= **30** 461 461 462 462 463 -(% style="color:red" %)Notice: In firmware v1.3, the Max bytes has been changed according to the max bytes in different Frequency Bands for lowest SF. As below: 524 +(% style="color:red" %)**Notice: In firmware v1.3, the Max bytes has been changed according to the max bytes in different Frequency Bands for lowest SF. As below:** 464 464 465 465 ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink. 466 466 ... ... @@ -473,11 +473,13 @@ 473 473 474 474 Below are the uplink payloads: 475 475 476 -[[image:1654157178836-407.png]] 537 +(% aria-label="1654157178836-407.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654157178836-407.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 477 477 478 478 540 + 479 479 === 3.3.5 Uplink on demand === 480 480 543 + 481 481 Except uplink periodically, RS485-LN is able to uplink on demand. The server send downlink command to RS485-LN and RS485 will uplink data base on the command. 482 482 483 483 Downlink control command: ... ... @@ -490,578 +490,945 @@ 490 490 491 491 === 3.3.6 Uplink on Interrupt === 492 492 556 + 493 493 RS485-LN support external Interrupt uplink since hardware v1.2 release. 494 494 495 -[[image:1654157342174-798.png]] 559 +(% aria-label="1654157342174-798.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654157342174-798.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 496 496 497 497 Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet. 498 498 499 499 564 + 500 500 == 3.4 Uplink Payload == 501 501 502 -(% border="1" style="background-color:#4bacc6; color:white; width:734px" %) 503 -|**Size(bytes)**|(% style="width:120px" %)**2**|(% style="width:116px" %)**1**|(% style="width:386px" %)**Length depends on the return from the commands** 504 -|Value|(% style="width:120px" %)((( 505 -Battery(mV) 506 506 507 - &568 +(% aria-label="image-20220606110929-1.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220606110929-1.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 508 508 509 -Interrupt _Flag 510 -)))|(% style="width:116px" %)((( 511 -PAYLOAD_VER 570 +Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 512 512 513 - 514 -)))|(% style="width:386px" %)If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server. 515 515 516 -Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 517 517 574 +== 3.5 Configure RS485-LN via AT or Downlink == 518 518 519 -== 3.5 Configure RS485-BL via AT or Downlink == 520 520 577 +((( 521 521 User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands 579 +))) 522 522 581 +((( 523 523 There are two kinds of Commands: 583 +))) 524 524 525 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 585 +* ((( 586 +(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 587 +))) 526 526 527 -* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN. User can see these commands below: 589 +* ((( 590 +(% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN. User can see these commands below: 591 +))) 528 528 593 +((( 594 + 595 +))) 596 + 597 + 598 + 529 529 === 3.5.1 Common Commands === 530 530 601 + 531 531 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 532 532 533 533 534 -=== 3.5.2 Sensor related commands === 535 535 606 +=== 3.5.2 Downlink Response(Since firmware v1.4) === 607 + 608 + 536 536 Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server. 537 537 538 -[[image:image-20220602163333-5.png||height="263" width="1160"]] 611 +(% aria-label="image-20220602163333-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602163333-5.png||data-widget="image" height="263" width="1160"]](% title="Click and drag to resize" %) 539 539 540 540 The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable) 541 541 542 542 616 + 543 543 === 3.5.3 Sensor related commands === 544 544 545 545 546 546 547 -==== **RS485 Debug Command** ==== 548 548 549 - ThiscommandisusedtoconfiguretheRS485devices; they won’tbeused duringsampling.622 +==== (% style="color:blue" %)**RS485 Debug Command**(%%) ==== 550 550 551 -* **AT Command** 552 552 553 -(% class="box infomessage" %) 554 554 ((( 555 - **AT+CFGDEV=xxxxxxxxxxxxxxxxxxxxxxxx,m**626 +This command is used to configure the RS485 devices; they won't be used during sampling. 556 556 ))) 557 557 558 -m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 629 +* ((( 630 +(% style="color:#037691" %)**AT Command** 559 559 560 -* **Downlink Payload** 632 +((( 633 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 634 +))) 635 +))) 561 561 637 +((( 638 + 639 +))) 640 + 641 +* ((( 642 +(% style="color:#037691" %)**Downlink Payload** 643 +))) 644 + 645 +((( 562 562 Format: A8 MM NN XX XX XX XX YY 647 +))) 563 563 649 +((( 564 564 Where: 651 +))) 565 565 566 -* MM: 1: add CRC-16/MODBUS ; 0: no CRC 567 -* NN: The length of RS485 command 568 -* XX XX XX XX: RS485 command total NN bytes 569 -* YY: How many bytes will be uplink from the return of this RS485 command, 570 -** if YY=0, RS485-LN will execute the downlink command without uplink; 571 -** if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200 572 -** if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200. 653 +* ((( 654 +MM: 1: add CRC-16/MODBUS ; 0: no CRC 655 +))) 656 +* ((( 657 +NN: The length of RS485 command 658 +))) 659 +* ((( 660 +XX XX XX XX: RS485 command total NN bytes 661 +))) 662 +* ((( 663 +((( 664 +YY: How many bytes will be uplink from the return of this RS485 command, 665 +))) 573 573 574 -**Example 1** ~-~-> Configure without ask for uplink (YY=0) 667 +* ((( 668 +if YY=0, RS485-LN will execute the downlink command without uplink; 669 +))) 670 +* ((( 671 +if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200 672 +))) 673 +* ((( 674 +if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200. 675 +))) 676 +))) 575 575 678 +((( 679 + 680 + 681 +(% style="color:blue" %)**Example 1:** (%%) ~-~-> Configure without ask for uplink (YY=0) 682 +))) 683 + 684 +((( 576 576 To connect a Modbus Alarm with below commands. 686 +))) 577 577 578 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 688 +* ((( 689 +The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 690 +))) 579 579 580 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 692 +* ((( 693 +The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 694 +))) 581 581 696 +((( 697 + 698 + 582 582 So if user want to use downlink command to control to RS485 Alarm, he can use: 700 +))) 583 583 702 +((( 584 584 (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 704 +))) 585 585 706 +((( 586 586 (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 708 +))) 587 587 710 +((( 588 588 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 712 +))) 589 589 714 +((( 715 + 716 +))) 590 590 591 -**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 718 +((( 719 +(% style="color:blue" %)**Example 2:** (%%) ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 720 +))) 592 592 722 +((( 593 593 User in IoT server send a downlink command: (% style="color:#4f81bd" %)**A8 01 06 0A 08 00 04 00 01 YY** 724 +))) 594 594 726 +((( 727 + 728 +))) 595 595 596 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: 730 +((( 731 +((( 732 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 733 +))) 597 597 598 - **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 735 + 736 +))) 599 599 600 - [[image:1654159460680-153.png]] 738 +((( 739 + (% aria-label="1654159460680-153.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654159460680-153.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 740 +))) 601 601 602 602 603 603 604 -==== **Set Payload version** ==== 605 605 606 - Thisisthe firstbyte of the uplink payload. RS485-BL can connect todifferent sensors. Usercan setthePAYVER fieldto tell serverhow to decode the currentpayload.745 +==== (% style="color:blue" %)**Set Payload version**(%%) ==== 607 607 608 -* **AT Command:** 609 609 610 -(% class="box infomessage" %) 611 611 ((( 612 - **AT+PAYVER:Set PAYVER field=1**749 +This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 613 613 ))) 614 614 615 -* **Downlink Payload:** 752 +* ((( 753 +(% style="color:#037691" %)**AT Command:** 616 616 617 -** 0xAE01**~-~->Set PAYVER field =0x01755 +**AT+PAYVER: **Set PAYVER field = 1 618 618 619 -**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 757 + 758 +))) 759 +* ((( 760 +(% style="color:#037691" %)**Downlink Payload:** 761 +))) 620 620 763 +((( 764 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 765 +))) 621 621 767 +((( 768 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 769 +))) 622 622 623 -==== **Set RS485 Sampling Commands** ==== 624 624 625 -AT+COMMANDx or AT+DATACUTx 626 626 627 -These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 628 628 774 +==== (% style="color:blue" %)**Set RS485 Sampling Commands**(%%) ==== 629 629 630 -* **AT Command:** 631 631 632 -(% class="box infomessage" %) 633 633 ((( 634 - **AT+COMMANDx:ConfigureRS485read command to sensor.**778 +AT+COMMANDx or AT+DATACUTx 635 635 ))) 636 636 637 -(% class="box infomessage" %) 638 638 ((( 639 - **AT+DATACUTx:Configure how tohandlereturnfromRS485 devices.**782 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 640 640 ))) 641 641 785 +((( 786 + 787 +))) 642 642 643 -* **Downlink Payload:** 789 +* ((( 790 +(% style="color:#037691" %)**AT Command:** 791 +))) 644 644 793 +**AT+COMMANDx: **Configure RS485 read command to sensor. 794 + 795 +**AT+DATACUTx: **Configure how to handle return from RS485 devices. 796 + 797 + 798 +* ((( 799 +(% style="color:#037691" %)**Downlink Payload:** 800 +))) 801 + 802 +((( 645 645 **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 646 646 805 + 806 +))) 807 + 808 +((( 647 647 (% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 648 648 811 + 812 +))) 813 + 814 +((( 649 649 Format: AF MM NN LL XX XX XX XX YY 816 +))) 650 650 818 +((( 651 651 Where: 820 +))) 652 652 653 -* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 654 -* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 655 -* LL: The length of AT+COMMAND or AT+DATACUT command 656 -* XX XX XX XX: AT+COMMAND or AT+DATACUT command 657 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 822 +* ((( 823 +MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 824 +))) 825 +* ((( 826 +NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 827 +))) 828 +* ((( 829 +LL: The length of AT+COMMAND or AT+DATACUT command 830 +))) 831 +* ((( 832 +XX XX XX XX: AT+COMMAND or AT+DATACUT command 833 +))) 834 +* ((( 835 +YY: If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 836 +))) 658 658 838 +((( 839 + 840 + 659 659 **Example:** 842 +))) 660 660 844 +((( 661 661 (% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1 846 +))) 662 662 848 +((( 663 663 (% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10** 850 +))) 664 664 852 +((( 665 665 (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10** 854 +))) 666 666 667 667 668 668 669 -==== **Fast command to handle MODBUS device** ==== 670 670 671 - AT+MBFUNisvalidsincev1.3 firmware version. Thecommand is forfast configure to readModbus devices. Itisonlyvalidfor the devices which follow the[[MODBUS-RTUprotocol>>url:https://www.modbustools.com/modbus.html]].859 +==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ==== 672 672 861 + 862 +((( 863 +**AT+MBFUN** is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 864 +))) 865 + 866 +((( 673 673 This command is valid since v1.3 firmware version 868 +))) 674 674 870 +((( 675 675 AT+MBFUN can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 872 +))) 676 676 874 +((( 875 + 876 +))) 677 677 878 +((( 678 678 **Example:** 880 +))) 679 679 680 -* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 681 -* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 682 -* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 882 +* ((( 883 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 884 +))) 885 +* ((( 886 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 887 +))) 888 +* ((( 889 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 683 683 684 -[[image:image-20220602165351-6.png]] 891 + 892 +))) 685 685 686 -[[image:image-20220602165351- 7.png]]894 +(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% title="Click and drag to resize" %) 687 687 896 +(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %) 688 688 689 689 690 -==== **RS485 command timeout** ==== 691 691 900 + 901 +==== (% style="color:blue" %)**RS485 command timeout**(%%) ==== 902 + 903 + 904 +((( 692 692 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. 906 +))) 693 693 908 +((( 694 694 Default value: 0, range: 0 ~~ 65 seconds 910 +))) 695 695 696 -* **AT Command:** 912 +* ((( 913 +(% style="color:#037691" %)** AT Command:** 697 697 698 -(% class="box infomessage" %) 699 -((( 700 700 **AT+CMDDLaa=hex(bb cc)*1000** 701 701 ))) 702 702 918 +((( 919 + 920 + 703 703 **Example:** 922 +))) 704 704 924 +((( 705 705 **AT+CMDDL1=1000** to send the open time to 1000ms 926 +))) 706 706 928 +((( 929 + 930 +))) 707 707 708 -* **Downlink Payload:** 932 +* ((( 933 +(% style="color:#037691" %)** Downlink Payload:** 934 +))) 709 709 936 +((( 710 710 **0x AA aa bb cc** 938 +))) 711 711 940 +((( 712 712 Same as: AT+CMDDLaa=hex(bb cc)*1000 942 +))) 713 713 714 - **Example:** 944 +((( 945 +**Example:** 946 +))) 715 715 716 - 0xAA 01 00 01 ~-~-> Same as **AT+CMDDL1=1000 ms** 948 +((( 949 +**0xAA 01 00 01** ~-~-> Same as **AT+CMDDL1=1000 ms** 950 +))) 717 717 718 718 719 719 720 -==== **Uplink payload mode** ==== 721 721 955 +==== (% style="color:blue" %)**Uplink payload mode**(%%) ==== 956 + 957 + 958 +((( 722 722 Define to use one uplink or multiple uplinks for the sampling. 960 +))) 723 723 962 +((( 724 724 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 725 725 726 -* **AT Command:** 965 + 966 +))) 727 727 728 -(% class="box infomessage" %) 729 -((( 730 -**AT+DATAUP=0** 968 +* ((( 969 +(% style="color:#037691" %)** AT Command:** 731 731 ))) 732 732 733 - (% class="box infomessage" %)734 - (((972 +**AT+DATAUP=0** 973 + 735 735 **AT+DATAUP=1** 736 -))) 737 737 738 738 739 -* **Downlink Payload:** 977 +* ((( 978 +(% style="color:#037691" %)** Downlink Payload:** 979 +))) 740 740 981 +((( 741 741 **0xAD 00** **~-~->** Same as AT+DATAUP=0 983 +))) 742 742 985 +((( 743 743 **0xAD 01** **~-~->** Same as AT+DATAUP=1 987 +))) 744 744 745 745 746 746 747 -==== **Manually trigger an Uplink** ==== 748 748 992 +==== (% style="color:blue" %)**Manually trigger an Uplink**(%%) ==== 993 + 994 + 995 +((( 749 749 Ask device to send an uplink immediately. 997 +))) 750 750 751 -* **AT Command:** 999 +* ((( 1000 +(% style="color:#037691" %)** AT Command:** 1001 +))) 752 752 1003 +((( 753 753 No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same. 1005 +))) 754 754 1007 +((( 1008 + 1009 +))) 755 755 756 -* **Downlink Payload:** 1011 +* ((( 1012 +(% style="color:#037691" %)** Downlink Payload:** 1013 +))) 757 757 1015 +((( 758 758 **0x08 FF**, RS485-LN will immediately send an uplink. 1017 +))) 759 759 760 760 761 761 762 -==== **Clear RS485 Command** ==== 763 763 1022 +==== (% style="color:blue" %)**Clear RS485 Command**(%%) ==== 1023 + 1024 + 1025 +((( 764 764 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 765 765 766 -* **AT Command:** 1028 + 1029 +))) 767 767 1031 +* ((( 1032 +(% style="color:#037691" %)** AT Command:** 1033 +))) 1034 + 1035 +((( 768 768 **AT+CMDEAR=mm,nn** mm: start position of erase ,nn: stop position of erase 1037 +))) 769 769 1039 +((( 770 770 Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1041 +))) 771 771 1043 +((( 772 772 Example screen shot after clear all RS485 commands. 1045 +))) 773 773 1047 +((( 1048 + 1049 +))) 774 774 1051 +((( 775 775 The uplink screen shot is: 1053 +))) 776 776 777 -[[image:1654160691922-496.png]] 1055 +(% aria-label="1654160691922-496.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654160691922-496.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 778 778 779 779 780 -* **Downlink Payload:** 1058 +* ((( 1059 +(% style="color:#037691" %)** Downlink Payload:** 1060 +))) 781 781 1062 +((( 782 782 **0x09 aa bb** same as AT+CMDEAR=aa,bb 1064 +))) 783 783 784 784 785 785 786 -==== **Set Serial Communication Parameters** ==== 787 787 788 - SettheRs485serialcommunicationparameters:1069 +==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%) ==== 789 789 790 -* **AT Command:** 791 791 792 -Set Baud Rate: 1072 +((( 1073 +Set the Rs485 serial communication parameters: 1074 +))) 793 793 794 -(% class="box infomessage" %) 1076 +* ((( 1077 +(% style="color:#037691" %)** AT Command:** 1078 +))) 1079 + 795 795 ((( 796 -**AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1081 + 1082 + 1083 +* Set Baud Rate 797 797 ))) 798 798 799 - Set UARTParity1086 +**AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 800 800 801 - (% class="box infomessage" %)1088 + 802 802 ((( 803 -* *AT+PARITY=0**~/~/ Option: 0: no parity, 1: odd parity, 2: even parity1090 +* Set UART Parity 804 804 ))) 805 805 806 - Set STOPBIT1093 +**AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 807 807 808 - (% class="box infomessage" %)1095 + 809 809 ((( 810 -* *AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits1097 +* Set STOPBIT 811 811 ))) 812 812 1100 +**AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 813 813 814 -* **Downlink Payload:** 815 815 816 -**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 817 817 1104 +* ((( 1105 +(% style="color:#037691" %)** Downlink Payload:** 1106 +))) 1107 + 1108 +((( 1109 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1110 +))) 1111 + 1112 +((( 818 818 **Example:** 1114 +))) 819 819 820 -* A7 01 00 60 same as AT+BAUDR=9600 821 -* A7 01 04 80 same as AT+BAUDR=115200 1116 +* ((( 1117 +A7 01 00 60 same as AT+BAUDR=9600 1118 +))) 1119 +* ((( 1120 +A7 01 04 80 same as AT+BAUDR=115200 1121 +))) 822 822 823 -A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1123 +((( 1124 +A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1125 +))) 824 824 825 -A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1127 +((( 1128 +A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1129 +))) 826 826 827 827 1132 + 1133 + 828 828 == 3.6 Listening mode for RS485 network == 829 829 1136 + 1137 +((( 830 830 This feature support since firmware v1.4 1139 +))) 831 831 1141 +((( 832 832 RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN. 833 833 834 -[[image:image-20220602171200-8.png||height="567" width="1007"]] 1144 + 1145 +))) 835 835 1147 +(% aria-label="image-20220602171200-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602171200-8.png||data-widget="image" height="567" width="1007"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1148 + 1149 +((( 836 836 To enable the listening mode, use can run the command AT+RXMODE. 1151 +))) 837 837 1153 +((( 1154 + 1155 +))) 838 838 839 -(% border="1" style="background-color:#ffffcc; width:500px" %) 840 -|=(% style="width: 161px;" %)**Command example:**|=(% style="width: 337px;" %)**Function** 841 -|(% style="width:161px" %)AT+RXMODE=1,10 |(% style="width:337px" %)Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 842 -|(% style="width:161px" %)AT+RXMODE=2,500|(% style="width:337px" %)Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 843 -|(% style="width:161px" %)AT+RXMODE=0,0|(% style="width:337px" %)Disable listening mode. This is the default settings. 844 -|(% style="width:161px" %) |(% style="width:337px" %)A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 ~| cc) 1157 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1158 +|=(% style="width: 100px;" %)((( 1159 +**Command example** 1160 +)))|=(% style="width: 400px;" %)((( 1161 +**Function** 1162 +))) 1163 +|(% style="width:100px" %)((( 1164 +AT+RXMODE=1,10 1165 +)))|(% style="width:400px" %)((( 1166 +Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1167 +))) 1168 +|(% style="width:100px" %)((( 1169 +AT+RXMODE=2,500 1170 +)))|(% style="width:400px" %)((( 1171 +Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1172 +))) 1173 +|(% style="width:100px" %)((( 1174 +AT+RXMODE=0,0 1175 +)))|(% style="width:400px" %)((( 1176 +Disable listening mode. This is the default settings. 1177 +))) 1178 +|(% style="width:100px" %)((( 1179 + 1180 +)))|(% style="width:400px" %)((( 1181 +A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1182 +))) 845 845 846 -**Downlink Command:** 1184 +((( 1185 +(% style="color:#037691" %)** Downlink Command:** 1186 +))) 847 847 1188 +((( 848 848 **0xA6 aa bb cc ** same as AT+RXMODE=aa,(bb<<8 | cc) 1190 +))) 849 849 1192 +((( 1193 + 1194 +))) 850 850 1196 +((( 851 851 **Example**: 1198 +))) 852 852 1200 +((( 853 853 The RS485-LN is set to AT+RXMODE=2,1000 1202 +))) 854 854 1204 +((( 855 855 There is a two Modbus commands in the RS485 network as below: 1206 +))) 856 856 1208 +((( 857 857 The Modbus master send a command: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b 1210 +))) 858 858 1212 +((( 859 859 And Modbus slave reply with: (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 1214 +))) 860 860 1216 +((( 861 861 RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 1218 +))) 862 862 863 -[[image:image-20220602171200-9.png]] 1220 +((( 1221 +(% aria-label="image-20220602171200-9.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602171200-9.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1222 +))) 864 864 1224 +((( 1225 + 1226 +))) 865 865 866 -(% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1228 +((( 1229 +((( 1230 +(% style="color:red" %)**Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.** 1231 +))) 1232 +))) 867 867 868 868 1235 + 869 869 == 3.7 Buttons == 870 870 871 871 872 -(% border="1" style="background-color:#f7faff; width: 500px" %)873 -|=**Button**|=(% style="width: 1 420px;" %)**Feature**874 -|**ACT**|(% style="width:1 420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**875 -|**RST**|(% style="width:1 420px" %)Reboot RS485876 -|**PRO**|(% style="width:1 420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]1239 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1240 +|=(% style="width: 50px;" %)**Button**|=(% style="width: 361px;" %)**Feature** 1241 +|(% style="width:50px" %)**ACT**|(% style="width:361px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 1242 +|(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485 1243 +|(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 877 877 878 878 1246 + 1247 + 879 879 == 3.8 LEDs == 880 880 881 -(% border="1" style="background-color:#f7faff; width:500px" %) 882 -|=**LEDs**|=**Feature** 1250 + 1251 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1252 +|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature** 883 883 |**PWR**|Always on if there is power 884 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink 1254 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 885 885 886 886 1257 + 1258 + 887 887 = 4. Case Study = 888 888 1261 + 889 889 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] 890 890 891 891 1265 + 892 892 = 5. Use AT Command = 893 893 1268 + 894 894 == 5.1 Access AT Command == 895 895 896 -RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 897 897 898 -[[image:1654162355560-817.png]] 1272 +((( 1273 +RS485-LN supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-LN to use AT command, as below. 1274 +))) 899 899 1276 +(% aria-label="1654162355560-817.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162355560-817.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 900 900 901 -In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 902 902 903 -[[image:1654162368066-342.png]] 1279 +((( 1280 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-LN. The default password is 123456. Below is the output for reference: 1281 +))) 904 904 1283 +(% aria-label="1654162368066-342.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162368066-342.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 905 905 1285 + 1286 +((( 906 906 More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1288 +))) 907 907 908 908 1291 + 909 909 == 5.2 Common AT Command Sequence == 910 910 1294 + 911 911 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 912 912 1297 + 913 913 If device has not joined network yet: 914 914 915 -(% class="box infomessage" %) 916 -((( 917 -**AT+FDR** 918 -))) 1300 +* (% style="color:#037691" %)**AT+FDR** 1301 +* (% style="color:#037691" %)**AT+NJM=0** 1302 +* (% style="color:#037691" %)**ATZ** 919 919 920 -(% class="box infomessage" %) 921 921 ((( 922 -**AT+NJM=0** 923 -))) 1305 + 924 924 925 -(% class="box infomessage" %) 926 -((( 927 -**ATZ** 928 -))) 929 - 930 - 931 931 If device already joined network: 932 932 933 -(% class="box infomessage" %) 934 -((( 935 -**AT+NJM=0** 936 -))) 1309 +* (% style="color:#037691" %)**AT+NJM=0** 1310 +* (% style="color:#037691" %)**ATZ** 937 937 938 -(% class="box infomessage" %) 939 -((( 940 -**ATZ** 1312 + 941 941 ))) 942 942 943 943 1316 + 944 944 === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 945 945 946 946 947 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1320 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 948 948 949 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 1322 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%) Set to ABP mode 950 950 951 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 1324 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) Set the Adaptive Data Rate Off 952 952 953 -(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 1326 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) Set Data Rate 954 954 955 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1328 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 956 956 957 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1330 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 958 958 959 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1332 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 960 960 961 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1334 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 962 962 963 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1336 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 964 964 965 -(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1338 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 966 966 967 967 968 968 (% style="color:red" %)**Note:** 969 969 1343 +((( 970 970 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 971 971 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 972 972 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 973 973 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 974 974 975 -[[image:1654162478620-421.png]] 1349 + 1350 +))) 976 976 1352 +(% aria-label="1654162478620-421.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162478620-421.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 977 977 1354 + 1355 + 978 978 = 6. FAQ = 979 979 1358 + 980 980 == 6.1 How to upgrade the image? == 981 981 1361 + 1362 +((( 982 982 The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to: 1364 +))) 983 983 984 -* Support new features 985 -* For bug fix 986 -* Change LoRaWAN bands. 1366 +* ((( 1367 +Support new features 1368 +))) 1369 +* ((( 1370 +For bug fix 1371 +))) 1372 +* ((( 1373 +Change LoRaWAN bands. 1374 +))) 987 987 1376 +((( 988 988 Below shows the hardware connection for how to upload an image to RS485-LN: 1378 +))) 989 989 990 -[[image:1654162535040-878.png]] 1380 +(% aria-label="1654162535040-878.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162535040-878.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]] 991 991 992 - **Step1:**Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].1382 +(% title="Click and drag to resize" %) 993 993 994 -**Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1384 +((( 1385 +(% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1386 +))) 995 995 996 -**Step3: **Open flashloader; choose the correct COM port to update. 1388 +((( 1389 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:https://www.dragino.com/downloads/index.php?dir=RS485-LN/Firmware/]]. 1390 +))) 997 997 998 998 ((( 1393 +(% style="color:blue" %)**Step3**(%%)**: **Open flashloader; choose the correct COM port to update. 1394 +))) 1395 + 1396 +((( 1397 +((( 1398 +((( 999 999 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 1000 1000 ))) 1401 +))) 1402 +))) 1001 1001 1002 1002 1003 -[[image:image-20220602175818-12.png]] 1405 +(% aria-label="image-20220602175818-12.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175818-12.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1004 1004 1005 1005 1006 -[[image:image-20220602175848-13.png]] 1408 +(% aria-label="image-20220602175848-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175848-13.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1007 1007 1008 1008 1009 -[[image:image-20220602175912-14.png]] 1411 +(% aria-label="image-20220602175912-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175912-14.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1010 1010 1011 1011 1012 -**Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1414 +(% style="color:red" %)**Notice**: **In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:** 1013 1013 1014 -[[image:image-20220602175638-10.png]] 1416 +(% aria-label="image-20220602175638-10.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175638-10.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1015 1015 1016 1016 1419 + 1017 1017 == 6.2 How to change the LoRa Frequency Bands/Region? == 1018 1018 1422 + 1019 1019 User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download. 1020 1020 1021 1021 1022 -== 6.3 How many RS485-Slave can RS485-BL connects? == 1023 1023 1024 - TheRS485-BLcan supportmax 32 RS485 devices. Each uplinkcommand ofRS485-BL can support max 16 differentRS485command.SoRS485-BL can support max 16 RS485 devices pre-program inthe device for uplink. For other devices no pre-program, user can usethe [[downlink message(type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].1427 +== 6.3 How many RS485-Slave can RS485-LN connects? == 1025 1025 1026 1026 1430 +The RS485-LN can support max 32 RS485 devices. Each uplink command of RS485-LN can support max 16 different RS485 command. So RS485-LN can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 1431 + 1432 + 1433 + 1027 1027 == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? == 1028 1028 1436 + 1029 1029 When user need to use with ChirpStack or TTI. Please set AT+RPL=4. 1030 1030 1031 1031 Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]] 1032 1032 1033 1033 1442 + 1443 +== 6.5 Can i use point to point communication for RS485-LN? == 1444 + 1445 + 1446 +Yes, please refer [[Point to Point Communication for RS485-LN>>Point to Point Communication for RS485-LN]]. 1447 + 1448 + 1449 + 1450 +== 6.6 How to Use RS485-LN to connect to RS232 devices? == 1451 + 1452 + 1453 +[[Use RS485-BL or RS485-LN to connect to RS232 devices. - DRAGINO>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/RS485%20to%20RS232/]] 1454 + 1455 + 1456 + 1034 1034 = 7. Trouble Shooting = 1035 1035 1036 -== 7.1 Downlink doesn’t work, how to solve it? == 1037 1037 1460 +== 7.1 Downlink doesn't work, how to solve it? == 1461 + 1462 + 1038 1038 Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]] 1039 1039 1040 1040 1041 -== 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? == 1042 1042 1467 +== 7.2 Why I can't join TTN V3 in US915 /AU915 bands? == 1468 + 1469 + 1043 1043 It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 1044 1044 1045 1045 1473 + 1046 1046 = 8. Order Info = 1047 1047 1476 + 1048 1048 (% style="color:blue" %)**Part Number: RS485-LN-XXX** 1049 1049 1050 1050 (% style="color:blue" %)**XXX:** 1051 1051 1052 -* (% style="color: blue" %)**EU433**(%%): frequency bands EU4331053 -* (% style="color: blue" %)**EU868**(%%): frequency bands EU8681054 -* (% style="color: blue" %)**KR920**(%%): frequency bands KR9201055 -* (% style="color: blue" %)**CN470**(%%): frequency bands CN4701056 -* (% style="color: blue" %)**AS923**(%%): frequency bands AS9231057 -* (% style="color: blue" %)**AU915**(%%): frequency bands AU9151058 -* (% style="color: blue" %)**US915**(%%): frequency bands US9151059 -* (% style="color: blue" %)**IN865**(%%): frequency bands IN8651060 -* (% style="color: blue" %)**RU864**(%%): frequency bands RU8641061 -* (% style="color: blue" %)**KZ865**(%%): frequency bands KZ8651481 +* (% style="color:red" %)**EU433**(%%): frequency bands EU433 1482 +* (% style="color:red" %)**EU868**(%%): frequency bands EU868 1483 +* (% style="color:red" %)**KR920**(%%): frequency bands KR920 1484 +* (% style="color:red" %)**CN470**(%%): frequency bands CN470 1485 +* (% style="color:red" %)**AS923**(%%): frequency bands AS923 1486 +* (% style="color:red" %)**AU915**(%%): frequency bands AU915 1487 +* (% style="color:red" %)**US915**(%%): frequency bands US915 1488 +* (% style="color:red" %)**IN865**(%%): frequency bands IN865 1489 +* (% style="color:red" %)**RU864**(%%): frequency bands RU864 1490 +* (% style="color:red" %)**KZ865**(%%): frequency bands KZ865 1062 1062 1063 1063 1064 1064 1494 + 1065 1065 = 9.Packing Info = 1066 1066 1067 1067 ... ... @@ -1080,8 +1080,10 @@ 1080 1080 1081 1081 1082 1082 1513 + 1083 1083 = 10. FCC Caution for RS485LN-US915 = 1084 1084 1516 + 1085 1085 ((( 1086 1086 Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 1087 1087 ))) ... ... @@ -1095,11 +1095,11 @@ 1095 1095 ))) 1096 1096 1097 1097 ((( 1098 -**IMPORTANT NOTE:** 1530 +(% style="color:red" %)**IMPORTANT NOTE:** 1099 1099 ))) 1100 1100 1101 1101 ((( 1102 -**Note: **This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1534 +(% style="color:red" %)**Note: **(%%)This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1103 1103 ))) 1104 1104 1105 1105 ((( ... ... @@ -1123,7 +1123,7 @@ 1123 1123 ))) 1124 1124 1125 1125 ((( 1126 -**FCC Radiation Exposure Statement:** 1558 +(% style="color:red" %)**FCC Radiation Exposure Statement:** 1127 1127 ))) 1128 1128 1129 1129 ((( ... ... @@ -1131,11 +1131,16 @@ 1131 1131 ))) 1132 1132 1133 1133 1566 + 1134 1134 = 11. Support = 1135 1135 1569 + 1136 1136 * ((( 1137 1137 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1138 1138 ))) 1139 1139 * ((( 1140 1140 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]. 1575 + 1576 + 1577 + 1141 1141 )))
- image-20220606110929-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.9 KB - Content
- image-20220824144240-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +110.9 KB - Content
- image-20220824145428-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.6 KB - Content