<
From version < 57.47 >
edited by Xiaoling
on 2022/06/06 10:49
To version < 57.46 >
edited by Xiaoling
on 2022/06/06 10:22
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -251,19 +251,19 @@
251 251  
252 252  To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
253 253  
254 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
255 -|=(% style="width: 110px;" %)(((
254 +(% border="1" style="background-color:#ffffcc; color:green; width:782px" %)
255 +|(% style="width:128px" %)(((
256 256  **AT Commands**
257 -)))|=(% style="width: 190px;" %)(((
257 +)))|(% style="width:305px" %)(((
258 258  **Description**
259 -)))|=(% style="width: 190px;" %)(((
259 +)))|(% style="width:346px" %)(((
260 260  **Example**
261 261  )))
262 -|(% style="width:110px" %)(((
262 +|(% style="width:128px" %)(((
263 263  AT+BAUDR
264 -)))|(% style="width:190px" %)(((
264 +)))|(% style="width:305px" %)(((
265 265  Set the baud rate (for RS485 connection). Default Value is: 9600.
266 -)))|(% style="width:190px" %)(((
266 +)))|(% style="width:346px" %)(((
267 267  (((
268 268  AT+BAUDR=9600
269 269  )))
... ... @@ -272,11 +272,11 @@
272 272  Options: (1200,2400,4800,14400,19200,115200)
273 273  )))
274 274  )))
275 -|(% style="width:110px" %)(((
275 +|(% style="width:128px" %)(((
276 276  AT+PARITY
277 -)))|(% style="width:190px" %)(((
277 +)))|(% style="width:305px" %)(((
278 278  Set UART parity (for RS485 connection)
279 -)))|(% style="width:190px" %)(((
279 +)))|(% style="width:346px" %)(((
280 280  (((
281 281  AT+PARITY=0
282 282  )))
... ... @@ -285,9 +285,9 @@
285 285  Option: 0: no parity, 1: odd parity, 2: even parity
286 286  )))
287 287  )))
288 -|(% style="width:110px" %)(((
288 +|(% style="width:128px" %)(((
289 289  AT+STOPBIT
290 -)))|(% style="width:190px" %)(((
290 +)))|(% style="width:305px" %)(((
291 291  (((
292 292  Set serial stopbit (for RS485 connection)
293 293  )))
... ... @@ -295,7 +295,7 @@
295 295  (((
296 296  
297 297  )))
298 -)))|(% style="width:190px" %)(((
298 +)))|(% style="width:346px" %)(((
299 299  (((
300 300  AT+STOPBIT=0 for 1bit
301 301  )))
... ... @@ -317,15 +317,15 @@
317 317  )))
318 318  )))
319 319  
320 -(% border="1" style="background-color:#ffffcc; color:green; width:510px" %)
321 -|(% style="width:110px" %)**AT Commands**|(% style="width:190px" %)**Description**|(% style="width:190px" %)**Example**
322 -|AT+CFGDEV|(% style="width:110px" %)(((
320 +(% border="1" style="background-color:#ffffcc; color:green; width:806px" %)
321 +|**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example**
322 +|AT+CFGDEV|(% style="width:418px" %)(((
323 323  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
324 324  
325 325  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
326 326  
327 327  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
328 -)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
328 +)))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
329 329  
330 330  === 3.3.3 Configure read commands for each sampling ===
331 331  
... ... @@ -372,8 +372,8 @@
372 372  
373 373  **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
374 374  
375 -(% border="1" style="background-color:#4bacc6; color:white; width:510px" %)
376 -|(% style="width:510px" %)(((
375 +(% border="1" style="background-color:#4bacc6; color:white; width:725px" %)
376 +|(% style="width:722px" %)(((
377 377  **AT+DATACUTx=a,b,c**
378 378  
379 379  * **a: length for the return of AT+COMMAND**
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0