Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -92,6 +92,8 @@ 92 92 * Automatic RF Sense and CAD with ultra-fast AFC. 93 93 * Packet engine up to 256 bytes with CRC 94 94 95 + 96 + 95 95 == 1.3 Features == 96 96 97 97 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -125,9 +125,13 @@ 125 125 126 126 ((( 127 127 ((( 130 +((( 128 128 v1.2: Add External Interrupt Pin. 132 +))) 129 129 134 +((( 130 130 v1.0: Release 136 +))) 131 131 132 132 133 133 ))) ... ... @@ -155,7 +155,9 @@ 155 155 == 3.1 How it works? == 156 156 157 157 ((( 164 +((( 158 158 The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA. 166 +))) 159 159 160 160 161 161 ))) ... ... @@ -231,11 +231,15 @@ 231 231 232 232 ((( 233 233 ((( 242 +((( 234 234 There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 235 235 ))) 245 +))) 236 236 237 237 ((( 248 +((( 238 238 (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 250 +))) 239 239 240 240 241 241 ))) ... ... @@ -245,19 +245,19 @@ 245 245 246 246 To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are: 247 247 248 -(% border="1" style="background-color:#ffffcc; color:green; width: 782px" %)249 -|(% style="width:1 28px" %)(((260 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 261 +|=(% style="width: 110px;" %)((( 250 250 **AT Commands** 251 -)))|(% style="width: 305px" %)(((263 +)))|=(% style="width: 190px;" %)((( 252 252 **Description** 253 -)))|(% style="width: 346px" %)(((265 +)))|=(% style="width: 190px;" %)((( 254 254 **Example** 255 255 ))) 256 -|(% style="width:1 28px" %)(((268 +|(% style="width:110px" %)((( 257 257 AT+BAUDR 258 -)))|(% style="width: 305px" %)(((270 +)))|(% style="width:190px" %)((( 259 259 Set the baud rate (for RS485 connection). Default Value is: 9600. 260 -)))|(% style="width: 346px" %)(((272 +)))|(% style="width:190px" %)((( 261 261 ((( 262 262 AT+BAUDR=9600 263 263 ))) ... ... @@ -266,11 +266,11 @@ 266 266 Options: (1200,2400,4800,14400,19200,115200) 267 267 ))) 268 268 ))) 269 -|(% style="width:1 28px" %)(((281 +|(% style="width:110px" %)((( 270 270 AT+PARITY 271 -)))|(% style="width: 305px" %)(((283 +)))|(% style="width:190px" %)((( 272 272 Set UART parity (for RS485 connection) 273 -)))|(% style="width: 346px" %)(((285 +)))|(% style="width:190px" %)((( 274 274 ((( 275 275 AT+PARITY=0 276 276 ))) ... ... @@ -279,9 +279,9 @@ 279 279 Option: 0: no parity, 1: odd parity, 2: even parity 280 280 ))) 281 281 ))) 282 -|(% style="width:1 28px" %)(((294 +|(% style="width:110px" %)((( 283 283 AT+STOPBIT 284 -)))|(% style="width: 305px" %)(((296 +)))|(% style="width:190px" %)((( 285 285 ((( 286 286 Set serial stopbit (for RS485 connection) 287 287 ))) ... ... @@ -289,7 +289,7 @@ 289 289 ((( 290 290 291 291 ))) 292 -)))|(% style="width: 346px" %)(((304 +)))|(% style="width:190px" %)((( 293 293 ((( 294 294 AT+STOPBIT=0 for 1bit 295 295 ))) ... ... @@ -311,15 +311,21 @@ 311 311 ))) 312 312 ))) 313 313 314 -(% border="1" style="background-color:#ffffcc; color:green; width:806px" %) 315 -|**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example** 316 -|AT+CFGDEV|(% style="width:418px" %)((( 326 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 327 +|=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 328 +|AT+CFGDEV|(% style="width:110px" %)((( 329 +((( 317 317 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 331 +))) 318 318 333 +((( 319 319 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 335 +))) 320 320 337 +((( 321 321 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 322 -)))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 339 +))) 340 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 323 323 324 324 === 3.3.3 Configure read commands for each sampling === 325 325 ... ... @@ -366,8 +366,8 @@ 366 366 367 367 **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes. 368 368 369 -(% border="1" style="background-color:#4bacc6; color:white; width: 725px" %)370 -|(% style="width: 722px" %)(((387 +(% border="1" style="background-color:#4bacc6; color:white; width:510px" %) 388 +|(% style="width:510px" %)((( 371 371 **AT+DATACUTx=a,b,c** 372 372 373 373 * **a: length for the return of AT+COMMAND** ... ... @@ -493,33 +493,35 @@ 493 493 494 494 == 3.4 Uplink Payload == 495 495 496 -(% border="1" style="background-color:#4bacc6; color:white; width:734px" %) 497 -|**Size(bytes)**|(% style="width:120px" %)**2**|(% style="width:116px" %)**1**|(% style="width:386px" %)**Length depends on the return from the commands** 498 -|Value|(% style="width:120px" %)((( 499 -Battery(mV) 500 500 501 - &515 +[[image:image-20220606110929-1.png]] 502 502 503 -Interrupt _Flag 504 -)))|(% style="width:116px" %)((( 505 -PAYLOAD_VER 506 - 507 - 508 -)))|(% style="width:386px" %)If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server. 509 - 510 510 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 511 511 512 512 513 513 == 3.5 Configure RS485-BL via AT or Downlink == 514 514 522 +((( 515 515 User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands 524 +))) 516 516 526 +((( 517 517 There are two kinds of Commands: 528 +))) 518 518 519 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 530 +* ((( 531 +(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 532 +))) 520 520 521 -* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN. User can see these commands below: 534 +* ((( 535 +(% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN. User can see these commands below: 536 +))) 522 522 538 +((( 539 + 540 +))) 541 + 542 + 523 523 === 3.5.1 Common Commands === 524 524 525 525 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -538,142 +538,282 @@ 538 538 539 539 540 540 561 + 541 541 ==== **RS485 Debug Command** ==== 542 542 564 +((( 543 543 This command is used to configure the RS485 devices; they won’t be used during sampling. 566 +))) 544 544 545 -* **AT Command** 568 +* ((( 569 +**AT Command** 570 +))) 546 546 547 547 (% class="box infomessage" %) 548 548 ((( 574 +((( 549 549 **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 550 550 ))) 577 +))) 551 551 579 +((( 552 552 m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 581 +))) 553 553 554 -* **Downlink Payload** 583 +* ((( 584 +**Downlink Payload** 585 +))) 555 555 587 +((( 556 556 Format: A8 MM NN XX XX XX XX YY 589 +))) 557 557 591 +((( 558 558 Where: 593 +))) 559 559 560 -* MM: 1: add CRC-16/MODBUS ; 0: no CRC 561 -* NN: The length of RS485 command 562 -* XX XX XX XX: RS485 command total NN bytes 563 -* YY: How many bytes will be uplink from the return of this RS485 command, 564 -** if YY=0, RS485-LN will execute the downlink command without uplink; 565 -** if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200 566 -** if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200. 595 +* ((( 596 +MM: 1: add CRC-16/MODBUS ; 0: no CRC 597 +))) 598 +* ((( 599 +NN: The length of RS485 command 600 +))) 601 +* ((( 602 +XX XX XX XX: RS485 command total NN bytes 603 +))) 604 +* ((( 605 +((( 606 +YY: How many bytes will be uplink from the return of this RS485 command, 607 +))) 567 567 609 +* ((( 610 +if YY=0, RS485-LN will execute the downlink command without uplink; 611 +))) 612 +* ((( 613 +if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200 614 +))) 615 +* ((( 616 +if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200. 617 +))) 618 +))) 619 + 620 +((( 568 568 **Example 1** ~-~-> Configure without ask for uplink (YY=0) 622 +))) 569 569 624 +((( 570 570 To connect a Modbus Alarm with below commands. 626 +))) 571 571 572 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 628 +* ((( 629 +The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 630 +))) 573 573 574 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 632 +* ((( 633 +The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 634 +))) 575 575 636 +((( 576 576 So if user want to use downlink command to control to RS485 Alarm, he can use: 638 +))) 577 577 640 +((( 578 578 (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 642 +))) 579 579 644 +((( 580 580 (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 646 +))) 581 581 648 +((( 582 582 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 650 +))) 583 583 652 +((( 653 + 654 +))) 584 584 656 +((( 585 585 **Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 658 +))) 586 586 660 +((( 587 587 User in IoT server send a downlink command: (% style="color:#4f81bd" %)**A8 01 06 0A 08 00 04 00 01 YY** 662 +))) 588 588 664 +((( 665 + 666 +))) 589 589 668 +((( 590 590 RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: 670 +))) 591 591 672 +((( 592 592 **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 674 +))) 593 593 676 +((( 594 594 [[image:1654159460680-153.png]] 678 +))) 595 595 596 596 597 597 682 + 598 598 ==== **Set Payload version** ==== 599 599 685 +((( 600 600 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 687 +))) 601 601 602 -* **AT Command:** 689 +* ((( 690 +**AT Command:** 691 +))) 603 603 604 604 (% class="box infomessage" %) 605 605 ((( 695 +((( 606 606 **AT+PAYVER: Set PAYVER field = 1** 607 607 ))) 698 +))) 608 608 609 -* **Downlink Payload:** 700 +* ((( 701 +**Downlink Payload:** 702 +))) 610 610 704 +((( 611 611 **0xAE 01** ~-~-> Set PAYVER field = 0x01 706 +))) 612 612 708 +((( 613 613 **0xAE 0F** ~-~-> Set PAYVER field = 0x0F 710 +))) 614 614 615 615 616 616 714 + 617 617 ==== **Set RS485 Sampling Commands** ==== 618 618 717 +((( 619 619 AT+COMMANDx or AT+DATACUTx 719 +))) 620 620 721 +((( 621 621 These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 723 +))) 622 622 725 +((( 726 + 727 +))) 623 623 624 -* **AT Command:** 729 +* ((( 730 +**AT Command:** 731 +))) 625 625 626 626 (% class="box infomessage" %) 627 627 ((( 735 +((( 628 628 **AT+COMMANDx: Configure RS485 read command to sensor.** 629 629 ))) 738 +))) 630 630 631 631 (% class="box infomessage" %) 632 632 ((( 742 +((( 633 633 **AT+DATACUTx: Configure how to handle return from RS485 devices.** 634 634 ))) 745 +))) 635 635 747 +((( 748 + 749 +))) 636 636 637 -* **Downlink Payload:** 751 +* ((( 752 +**Downlink Payload:** 753 +))) 638 638 755 +((( 639 639 **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 757 +))) 640 640 759 +((( 641 641 (% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 761 +))) 642 642 763 +((( 643 643 Format: AF MM NN LL XX XX XX XX YY 765 +))) 644 644 767 +((( 645 645 Where: 769 +))) 646 646 647 -* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 648 -* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 649 -* LL: The length of AT+COMMAND or AT+DATACUT command 650 -* XX XX XX XX: AT+COMMAND or AT+DATACUT command 651 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 771 +* ((( 772 +MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 773 +))) 774 +* ((( 775 +NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 776 +))) 777 +* ((( 778 +LL: The length of AT+COMMAND or AT+DATACUT command 779 +))) 780 +* ((( 781 +XX XX XX XX: AT+COMMAND or AT+DATACUT command 782 +))) 783 +* ((( 784 +YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 785 +))) 652 652 787 +((( 653 653 **Example:** 789 +))) 654 654 791 +((( 655 655 (% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1 793 +))) 656 656 795 +((( 657 657 (% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10** 797 +))) 658 658 799 +((( 659 659 (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10** 801 +))) 660 660 661 661 662 662 805 + 663 663 ==== **Fast command to handle MODBUS device** ==== 664 664 808 +((( 665 665 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 810 +))) 666 666 812 +((( 667 667 This command is valid since v1.3 firmware version 814 +))) 668 668 816 +((( 669 669 AT+MBFUN can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 818 +))) 670 670 820 +((( 821 + 822 +))) 671 671 824 +((( 672 672 **Example:** 826 +))) 673 673 674 -* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 675 -* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 676 -* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 828 +* ((( 829 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 830 +))) 831 +* ((( 832 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 833 +))) 834 +* ((( 835 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 836 +))) 677 677 678 678 [[image:image-20220602165351-6.png]] 679 679 ... ... @@ -681,203 +681,375 @@ 681 681 682 682 683 683 844 + 684 684 ==== **RS485 command timeout** ==== 685 685 847 +((( 686 686 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. 849 +))) 687 687 851 +((( 688 688 Default value: 0, range: 0 ~~ 65 seconds 853 +))) 689 689 690 -* **AT Command:** 855 +* ((( 856 +**AT Command:** 857 +))) 691 691 692 692 (% class="box infomessage" %) 693 693 ((( 861 +((( 694 694 **AT+CMDDLaa=hex(bb cc)*1000** 695 695 ))) 864 +))) 696 696 866 +((( 697 697 **Example:** 868 +))) 698 698 870 +((( 699 699 **AT+CMDDL1=1000** to send the open time to 1000ms 872 +))) 700 700 874 +((( 875 + 876 +))) 701 701 702 -* **Downlink Payload:** 878 +* ((( 879 +**Downlink Payload:** 880 +))) 703 703 882 +((( 704 704 **0x AA aa bb cc** 884 +))) 705 705 886 +((( 706 706 Same as: AT+CMDDLaa=hex(bb cc)*1000 888 +))) 707 707 890 +((( 708 708 **Example:** 892 +))) 709 709 894 +((( 710 710 0xAA 01 00 01 ~-~-> Same as **AT+CMDDL1=1000 ms** 896 +))) 711 711 712 712 713 713 900 + 714 714 ==== **Uplink payload mode** ==== 715 715 903 +((( 716 716 Define to use one uplink or multiple uplinks for the sampling. 905 +))) 717 717 907 +((( 718 718 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 909 +))) 719 719 720 -* **AT Command:** 911 +* ((( 912 +**AT Command:** 913 +))) 721 721 722 722 (% class="box infomessage" %) 723 723 ((( 917 +((( 724 724 **AT+DATAUP=0** 725 725 ))) 920 +))) 726 726 727 727 (% class="box infomessage" %) 728 728 ((( 924 +((( 729 729 **AT+DATAUP=1** 730 730 ))) 927 +))) 731 731 929 +((( 930 + 931 +))) 732 732 733 -* **Downlink Payload:** 933 +* ((( 934 +**Downlink Payload:** 935 +))) 734 734 937 +((( 735 735 **0xAD 00** **~-~->** Same as AT+DATAUP=0 939 +))) 736 736 941 +((( 737 737 **0xAD 01** **~-~->** Same as AT+DATAUP=1 943 +))) 738 738 739 739 740 740 947 + 741 741 ==== **Manually trigger an Uplink** ==== 742 742 950 +((( 743 743 Ask device to send an uplink immediately. 952 +))) 744 744 745 -* **AT Command:** 954 +* ((( 955 +**AT Command:** 956 +))) 746 746 958 +((( 747 747 No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same. 960 +))) 748 748 962 +((( 963 + 964 +))) 749 749 750 -* **Downlink Payload:** 966 +* ((( 967 +**Downlink Payload:** 968 +))) 751 751 970 +((( 752 752 **0x08 FF**, RS485-LN will immediately send an uplink. 972 +))) 753 753 754 754 755 755 976 + 756 756 ==== **Clear RS485 Command** ==== 757 757 979 +((( 758 758 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 981 +))) 759 759 760 -* **AT Command:** 983 +* ((( 984 +**AT Command:** 985 +))) 761 761 987 +((( 762 762 **AT+CMDEAR=mm,nn** mm: start position of erase ,nn: stop position of erase 989 +))) 763 763 991 +((( 764 764 Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 993 +))) 765 765 995 +((( 766 766 Example screen shot after clear all RS485 commands. 997 +))) 767 767 999 +((( 1000 + 1001 +))) 768 768 1003 +((( 769 769 The uplink screen shot is: 1005 +))) 770 770 771 771 [[image:1654160691922-496.png]] 772 772 773 773 774 -* **Downlink Payload:** 1010 +* ((( 1011 +**Downlink Payload:** 1012 +))) 775 775 1014 +((( 776 776 **0x09 aa bb** same as AT+CMDEAR=aa,bb 1016 +))) 777 777 778 778 779 779 1020 + 780 780 ==== **Set Serial Communication Parameters** ==== 781 781 1023 +((( 782 782 Set the Rs485 serial communication parameters: 1025 +))) 783 783 784 -* **AT Command:** 1027 +* ((( 1028 +**AT Command:** 1029 +))) 785 785 1031 +((( 786 786 Set Baud Rate: 1033 +))) 787 787 788 788 (% class="box infomessage" %) 789 789 ((( 1037 +((( 790 790 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 791 791 ))) 1040 +))) 792 792 1042 +((( 793 793 Set UART Parity 1044 +))) 794 794 795 795 (% class="box infomessage" %) 796 796 ((( 1048 +((( 797 797 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 798 798 ))) 1051 +))) 799 799 1053 +((( 800 800 Set STOPBIT 1055 +))) 801 801 802 802 (% class="box infomessage" %) 803 803 ((( 1059 +((( 804 804 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 805 805 ))) 1062 +))) 806 806 1064 +((( 1065 + 1066 +))) 807 807 808 -* **Downlink Payload:** 1068 +* ((( 1069 +**Downlink Payload:** 1070 +))) 809 809 1072 +((( 810 810 **A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1074 +))) 811 811 1076 +((( 812 812 **Example:** 1078 +))) 813 813 814 -* A7 01 00 60 same as AT+BAUDR=9600 815 -* A7 01 04 80 same as AT+BAUDR=115200 1080 +* ((( 1081 +A7 01 00 60 same as AT+BAUDR=9600 1082 +))) 1083 +* ((( 1084 +A7 01 04 80 same as AT+BAUDR=115200 1085 +))) 816 816 1087 +((( 817 817 A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1089 +))) 818 818 1091 +((( 819 819 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1093 +))) 820 820 821 821 1096 + 1097 + 822 822 == 3.6 Listening mode for RS485 network == 823 823 1100 +((( 824 824 This feature support since firmware v1.4 1102 +))) 825 825 1104 +((( 826 826 RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN. 1106 +))) 827 827 828 828 [[image:image-20220602171200-8.png||height="567" width="1007"]] 829 829 1110 +((( 830 830 To enable the listening mode, use can run the command AT+RXMODE. 1112 +))) 831 831 1114 +((( 1115 + 1116 +))) 832 832 833 -(% border="1" style="background-color:#ffffcc; width:500px" %) 834 -|=(% style="width: 161px;" %)**Command example:**|=(% style="width: 337px;" %)**Function** 835 -|(% style="width:161px" %)AT+RXMODE=1,10 |(% style="width:337px" %)Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 836 -|(% style="width:161px" %)AT+RXMODE=2,500|(% style="width:337px" %)Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 837 -|(% style="width:161px" %)AT+RXMODE=0,0|(% style="width:337px" %)Disable listening mode. This is the default settings. 838 -|(% style="width:161px" %) |(% style="width:337px" %)A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 ~| cc) 1118 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1119 +|=(% style="width: 100px;" %)((( 1120 +**Command example** 1121 +)))|=(% style="width: 400px;" %)((( 1122 +**Function** 1123 +))) 1124 +|(% style="width:100px" %)((( 1125 +AT+RXMODE=1,10 1126 +)))|(% style="width:400px" %)((( 1127 +Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1128 +))) 1129 +|(% style="width:100px" %)((( 1130 +AT+RXMODE=2,500 1131 +)))|(% style="width:400px" %)((( 1132 +Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1133 +))) 1134 +|(% style="width:100px" %)((( 1135 +AT+RXMODE=0,0 1136 +)))|(% style="width:400px" %)((( 1137 +Disable listening mode. This is the default settings. 1138 +))) 1139 +|(% style="width:100px" %)((( 1140 + 1141 +)))|(% style="width:400px" %)((( 1142 +A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1143 +))) 839 839 1145 +((( 840 840 **Downlink Command:** 1147 +))) 841 841 1149 +((( 842 842 **0xA6 aa bb cc ** same as AT+RXMODE=aa,(bb<<8 | cc) 1151 +))) 843 843 1153 +((( 1154 + 1155 +))) 844 844 1157 +((( 845 845 **Example**: 1159 +))) 846 846 1161 +((( 847 847 The RS485-LN is set to AT+RXMODE=2,1000 1163 +))) 848 848 1165 +((( 849 849 There is a two Modbus commands in the RS485 network as below: 1167 +))) 850 850 1169 +((( 851 851 The Modbus master send a command: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b 1171 +))) 852 852 1173 +((( 853 853 And Modbus slave reply with: (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 1175 +))) 854 854 1177 +((( 855 855 RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 1179 +))) 856 856 1181 +((( 857 857 [[image:image-20220602171200-9.png]] 1183 +))) 858 858 1185 +((( 1186 + 1187 +))) 859 859 1189 +((( 1190 +((( 860 860 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1192 +))) 1193 +))) 861 861 862 862 863 863 == 3.7 Buttons == 864 864 865 865 866 -(% border="1" style="background-color:#f7faff; width: 500px" %)867 -|=**Button**|=(% style="width: 1420px;" %)**Feature**868 -|**ACT**|(% style="width: 1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**869 -|**RST**|(% style="width: 1420px" %)Reboot RS485870 -|**PRO**|(% style="width: 1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]1199 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:400px" %) 1200 +|=(% style="width: 50px;" %)**Button**|=(% style="width: 350px;" %)**Feature** 1201 +|(% style="width:50px" %)**ACT**|(% style="width:350px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 1202 +|(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485 1203 +|(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 871 871 872 - 873 873 == 3.8 LEDs == 874 874 875 -(% border="1" style="background-color:#f7faff; width:500px" %) 876 -|=**LEDs**|=**Feature** 1207 + 1208 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1209 +|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature** 877 877 |**PWR**|Always on if there is power 878 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink 1211 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 879 879 880 - 881 881 = 4. Case Study = 882 882 883 883 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -887,19 +887,26 @@ 887 887 888 888 == 5.1 Access AT Command == 889 889 1222 +((( 890 890 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1224 +))) 891 891 892 892 [[image:1654162355560-817.png]] 893 893 894 894 1229 +((( 895 895 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1231 +))) 896 896 897 897 [[image:1654162368066-342.png]] 898 898 899 899 1236 +((( 900 900 More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1238 +))) 901 901 902 902 1241 + 903 903 == 5.2 Common AT Command Sequence == 904 904 905 905 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === ... ... @@ -922,7 +922,9 @@ 922 922 ))) 923 923 924 924 1264 +((( 925 925 If device already joined network: 1266 +))) 926 926 927 927 (% class="box infomessage" %) 928 928 ((( ... ... @@ -961,10 +961,12 @@ 961 961 962 962 (% style="color:red" %)**Note:** 963 963 1305 +((( 964 964 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 965 965 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 966 966 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 967 967 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1310 +))) 968 968 969 969 [[image:1654162478620-421.png]] 970 970 ... ... @@ -973,25 +973,45 @@ 973 973 974 974 == 6.1 How to upgrade the image? == 975 975 1319 +((( 976 976 The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to: 1321 +))) 977 977 978 -* Support new features 979 -* For bug fix 980 -* Change LoRaWAN bands. 1323 +* ((( 1324 +Support new features 1325 +))) 1326 +* ((( 1327 +For bug fix 1328 +))) 1329 +* ((( 1330 +Change LoRaWAN bands. 1331 +))) 981 981 1333 +((( 982 982 Below shows the hardware connection for how to upload an image to RS485-LN: 1335 +))) 983 983 984 984 [[image:1654162535040-878.png]] 985 985 1339 +((( 986 986 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1341 +))) 987 987 1343 +((( 988 988 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1345 +))) 989 989 1347 +((( 990 990 **Step3: **Open flashloader; choose the correct COM port to update. 1349 +))) 991 991 992 992 ((( 1352 +((( 1353 +((( 993 993 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 994 994 ))) 1356 +))) 1357 +))) 995 995 996 996 997 997 [[image:image-20220602175818-12.png]] ... ... @@ -1054,8 +1054,6 @@ 1054 1054 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1055 1055 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1056 1056 1057 - 1058 - 1059 1059 = 9.Packing Info = 1060 1060 1061 1061 ... ... @@ -1072,8 +1072,6 @@ 1072 1072 * Package Size / pcs : 14.5 x 8 x 5 cm 1073 1073 * Weight / pcs : 170g 1074 1074 1075 - 1076 - 1077 1077 = 10. FCC Caution for RS485LN-US915 = 1078 1078 1079 1079 (((
- image-20220606110929-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.9 KB - Content