Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -103,6 +103,7 @@ 103 103 * Support Modbus protocol 104 104 * Support Interrupt uplink (Since hardware version v1.2) 105 105 106 + 106 106 == 1.4 Applications == 107 107 108 108 * Smart Buildings & Home Automation ... ... @@ -112,6 +112,7 @@ 112 112 * Smart Cities 113 113 * Smart Factory 114 114 116 + 115 115 == 1.5 Firmware Change log == 116 116 117 117 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -121,9 +121,13 @@ 121 121 122 122 ((( 123 123 ((( 126 +((( 124 124 v1.2: Add External Interrupt Pin. 128 +))) 125 125 130 +((( 126 126 v1.0: Release 132 +))) 127 127 128 128 129 129 ))) ... ... @@ -151,7 +151,9 @@ 151 151 == 3.1 How it works? == 152 152 153 153 ((( 160 +((( 154 154 The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA. 162 +))) 155 155 156 156 157 157 ))) ... ... @@ -241,19 +241,19 @@ 241 241 242 242 To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are: 243 243 244 -(% border="1" style="background-color:#ffffcc; color:green; width: 782px" %)245 -|(% style="width:1 28px" %)(((252 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 253 +|=(% style="width: 110px;" %)((( 246 246 **AT Commands** 247 -)))|(% style="width: 305px" %)(((255 +)))|=(% style="width: 190px;" %)((( 248 248 **Description** 249 -)))|(% style="width: 346px" %)(((257 +)))|=(% style="width: 190px;" %)((( 250 250 **Example** 251 251 ))) 252 -|(% style="width:1 28px" %)(((260 +|(% style="width:110px" %)((( 253 253 AT+BAUDR 254 -)))|(% style="width: 305px" %)(((262 +)))|(% style="width:190px" %)((( 255 255 Set the baud rate (for RS485 connection). Default Value is: 9600. 256 -)))|(% style="width: 346px" %)(((264 +)))|(% style="width:190px" %)((( 257 257 ((( 258 258 AT+BAUDR=9600 259 259 ))) ... ... @@ -262,11 +262,11 @@ 262 262 Options: (1200,2400,4800,14400,19200,115200) 263 263 ))) 264 264 ))) 265 -|(% style="width:1 28px" %)(((273 +|(% style="width:110px" %)((( 266 266 AT+PARITY 267 -)))|(% style="width: 305px" %)(((275 +)))|(% style="width:190px" %)((( 268 268 Set UART parity (for RS485 connection) 269 -)))|(% style="width: 346px" %)(((277 +)))|(% style="width:190px" %)((( 270 270 ((( 271 271 AT+PARITY=0 272 272 ))) ... ... @@ -275,9 +275,9 @@ 275 275 Option: 0: no parity, 1: odd parity, 2: even parity 276 276 ))) 277 277 ))) 278 -|(% style="width:1 28px" %)(((286 +|(% style="width:110px" %)((( 279 279 AT+STOPBIT 280 -)))|(% style="width: 305px" %)(((288 +)))|(% style="width:190px" %)((( 281 281 ((( 282 282 Set serial stopbit (for RS485 connection) 283 283 ))) ... ... @@ -285,7 +285,7 @@ 285 285 ((( 286 286 287 287 ))) 288 -)))|(% style="width: 346px" %)(((296 +)))|(% style="width:190px" %)((( 289 289 ((( 290 290 AT+STOPBIT=0 for 1bit 291 291 ))) ... ... @@ -299,6 +299,8 @@ 299 299 ))) 300 300 ))) 301 301 310 + 311 + 302 302 === 3.3.2 Configure sensors === 303 303 304 304 ((( ... ... @@ -307,16 +307,18 @@ 307 307 ))) 308 308 ))) 309 309 310 -(% border="1" style="background-color:#ffffcc; color:green; width: 806px" %)311 -|**AT Commands**|(% style="width: 418px" %)**Description**|(% style="width:256px" %)**Example**312 -|AT+CFGDEV|(% style="width: 418px" %)(((320 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 321 +|=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 322 +|AT+CFGDEV|(% style="width:110px" %)((( 313 313 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 314 314 315 315 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 316 316 317 317 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 318 -)))|(% style="width: 256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m328 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 319 319 330 + 331 + 320 320 === 3.3.3 Configure read commands for each sampling === 321 321 322 322 ((( ... ... @@ -362,8 +362,8 @@ 362 362 363 363 **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes. 364 364 365 -(% border="1" style="background-color:#4bacc6; color:white; width: 725px" %)366 -|(% style="width: 722px" %)(((377 +(% border="1" style="background-color:#4bacc6; color:white; width:510px" %) 378 +|(% style="width:510px" %)((( 367 367 **AT+DATACUTx=a,b,c** 368 368 369 369 * **a: length for the return of AT+COMMAND** ... ... @@ -865,7 +865,6 @@ 865 865 |**RST**|(% style="width:1420px" %)Reboot RS485 866 866 |**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 867 867 868 - 869 869 == 3.8 LEDs == 870 870 871 871 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -873,7 +873,6 @@ 873 873 |**PWR**|Always on if there is power 874 874 |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 875 875 876 - 877 877 = 4. Case Study = 878 878 879 879 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -1051,7 +1051,6 @@ 1051 1051 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1052 1052 1053 1053 1054 - 1055 1055 = 9.Packing Info = 1056 1056 1057 1057 ... ... @@ -1069,7 +1069,6 @@ 1069 1069 * Weight / pcs : 170g 1070 1070 1071 1071 1072 - 1073 1073 = 10. FCC Caution for RS485LN-US915 = 1074 1074 1075 1075 (((