Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -RS485-LN – RS485 to LoRaWAN Converter 1 +RS485-LN – RS485 to LoRaWAN Converter User Manual - Content
-
... ... @@ -1,54 +1,80 @@ 1 -(% style="text-align:center" %) 2 -[[image:1653266934636-343.png||height="385" width="385"]] 1 +(% aria-label="1653266934636-343.png image widget" contenteditable="false" role="region" tabindex="-1" %) 2 +((( 3 +(% data-widget="image" style="text-align:center" %) 4 +[[image:1653266934636-343.png||height="385" width="385"]](% title="Click and drag to resize" %) 3 3 6 +(% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||height="15" role="presentation" title="Click and drag to move" width="15"]] 7 +))) 4 4 5 5 6 -**RS485-LN – RS485 to LoRaWAN Converter User Manual** 7 7 8 8 9 9 10 10 14 + 11 11 **Table of Contents:** 12 12 13 13 {{toc/}} 14 14 15 15 20 +(% aria-label="macro:toc widget" contenteditable="false" role="region" tabindex="-1" %) 21 +((( 22 +(% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||height="15" role="presentation" title="Click and drag to move" width="15"]] 23 +))) 16 16 17 17 18 18 19 19 20 20 29 + 30 + 21 21 = 1.Introduction = 22 22 33 + 23 23 == 1.1 What is RS485-LN RS485 to LoRaWAN Converter == 24 24 25 25 ((( 26 26 ((( 38 +((( 39 + 40 + 27 27 The Dragino RS485-LN is a (% style="color:blue" %)**RS485 to LoRaWAN Converter**(%%). It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost. 28 28 ))) 43 +))) 29 29 30 30 ((( 46 +((( 31 31 RS485-LN allows user to (% style="color:blue" %)**monitor / control RS485 devices**(%%) and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on. 32 32 ))) 49 +))) 33 33 34 34 ((( 52 +((( 35 35 (% style="color:blue" %)**For data uplink**(%%), RS485-LN sends user-defined commands to RS485 devices and gets the return from the RS485 devices. RS485-LN will process these returns according to user-define rules to get the final payload and upload to LoRaWAN server. 36 36 ))) 55 +))) 37 37 38 38 ((( 58 +((( 39 39 (% style="color:blue" %)**For data downlink**(%%), RS485-LN runs in LoRaWAN Class C. When there downlink commands from LoRaWAN server, RS485-LN will forward the commands from LoRaWAN server to RS485 devices. 60 +))) 40 40 62 +((( 41 41 (% style="color:blue" %)**Demo Dashboard for RS485-LN**(%%) connect to two energy meters: [[https:~~/~~/app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a>>url:https://app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a]] 64 + 65 + 42 42 ))) 43 43 ))) 68 +))) 44 44 45 -[[image:1653267211009-519.png||height="419" width="724"]] 70 +(% aria-label="1653267211009-519.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653267211009-519.png||data-widget="image" height="419" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 46 46 47 47 73 + 48 48 == 1.2 Specifications == 49 49 50 50 51 -**Hardware System:** 77 +(% style="color:#037691" %)**Hardware System:** 52 52 53 53 * STM32L072CZT6 MCU 54 54 * SX1276/78 Wireless Chip ... ... @@ -56,13 +56,17 @@ 56 56 ** Idle: 32mA@12v 57 57 ** 20dB Transmit: 65mA@12v 58 58 59 -**Interface for Model:** 60 60 86 + 87 +(% style="color:#037691" %)**Interface for Model:** 88 + 61 61 * RS485 62 62 * Power Input 7~~ 24V DC. 63 63 64 -**LoRa Spec:** 65 65 93 + 94 +(% style="color:#037691" %)**LoRa Spec:** 95 + 66 66 * Frequency Range: 67 67 ** Band 1 (HF): 862 ~~ 1020 Mhz 68 68 ** Band 2 (LF): 410 ~~ 528 Mhz ... ... @@ -82,10 +82,14 @@ 82 82 * Automatic RF Sense and CAD with ultra-fast AFC. 83 83 * Packet engine up to 256 bytes with CRC 84 84 115 + 116 + 117 + 85 85 == 1.3 Features == 86 86 120 + 87 87 * LoRaWAN Class A & Class C protocol (default Class C) 88 -* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864 122 +* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864/MA869 89 89 * AT Commands to change parameters 90 90 * Remote configure parameters via LoRa Downlink 91 91 * Firmware upgradable via program port ... ... @@ -93,8 +93,12 @@ 93 93 * Support Modbus protocol 94 94 * Support Interrupt uplink (Since hardware version v1.2) 95 95 130 + 131 + 132 + 96 96 == 1.4 Applications == 97 97 135 + 98 98 * Smart Buildings & Home Automation 99 99 * Logistics and Supply Chain Management 100 100 * Smart Metering ... ... @@ -102,19 +102,30 @@ 102 102 * Smart Cities 103 103 * Smart Factory 104 104 143 + 144 + 145 + 105 105 == 1.5 Firmware Change log == 106 106 148 + 107 107 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] 108 108 109 109 152 + 110 110 == 1.6 Hardware Change log == 111 111 155 + 112 112 ((( 113 113 ((( 158 +((( 114 114 v1.2: Add External Interrupt Pin. 160 +))) 115 115 162 +((( 116 116 v1.0: Release 164 +))) 117 117 166 + 118 118 119 119 ))) 120 120 ))) ... ... @@ -121,6 +121,7 @@ 121 121 122 122 = 2. Power ON Device = 123 123 173 + 124 124 ((( 125 125 The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below 126 126 ... ... @@ -131,28 +131,36 @@ 131 131 Once there is power, the RS485-LN will be on. 132 132 ))) 133 133 134 -[[image:1653268091319-405.png]] 184 +(% aria-label="1653268091319-405.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653268091319-405.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 135 135 186 + 136 136 137 137 ))) 138 138 139 139 = 3. Operation Mode = 140 140 192 + 141 141 == 3.1 How it works? == 142 142 195 + 143 143 ((( 197 +((( 144 144 The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA. 199 +))) 145 145 201 + 146 146 147 147 ))) 148 148 149 149 == 3.2 Example to join LoRaWAN network == 150 150 207 + 151 151 Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 152 152 153 -[[image:1653268155545-638.png||height="334" width="724"]] 154 154 211 +(% aria-label="1653268155545-638.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653268155545-638.png||data-widget="image" height="334" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 155 155 213 + 156 156 ((( 157 157 ((( 158 158 The RS485-LN in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. The connection is as below: ... ... @@ -160,16 +160,21 @@ 160 160 161 161 ((( 162 162 485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively. 221 + 222 + 163 163 ))) 164 164 165 -[[image:1653268227651-549.png||height="592" width="720"]] 225 +(% aria-label="1653268227651-549.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653268227651-549.png||data-widget="image" height="592" width="720"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 166 166 227 + 167 167 ((( 168 168 The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3: 230 + 231 + 169 169 ))) 170 170 171 171 ((( 172 -**Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-LN. 235 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN V3 with the OTAA keys from RS485-LN. 173 173 ))) 174 174 175 175 ((( ... ... @@ -177,73 +177,95 @@ 177 177 ))) 178 178 ))) 179 179 180 -[[image:1652953462722-299.png]] 243 +(% aria-label="1652953462722-299.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1652953462722-299.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 181 181 245 + 182 182 ((( 183 183 ((( 184 184 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot: 249 + 250 + 185 185 ))) 186 186 187 187 ((( 188 -Add APP EUI in the application. 254 +**Add APP EUI in the application.** 189 189 ))) 190 190 ))) 191 191 192 -[[image:image-20220519174512-1.png]] 258 +(% aria-label="image-20220519174512-1.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220519174512-1.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 193 193 194 -[[image:image-20220519174512-2.png||height="323" width="720"]] 260 +(% aria-label="image-20220519174512-2.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220519174512-2.png||data-widget="image" height="323" width="720"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 195 195 196 -[[image:image-20220519174512-3.png||height="556" width="724"]] 262 +(% aria-label="image-20220519174512-3.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220519174512-3.png||data-widget="image" height="556" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 197 197 198 -[[image:image-20220519174512-4.png]] 264 +(% aria-label="image-20220519174512-4.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220519174512-4.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]] 199 199 266 + 267 +(% title="Click and drag to resize" %) 268 + 200 200 You can also choose to create the device manually. 201 201 202 -[[image:1652953542269-423.png||height="710" width="723"]] 271 +(% aria-label="1652953542269-423.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1652953542269-423.png||data-widget="image" height="710" width="723"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 203 203 204 -Add APP KEY and DEV EUI 205 205 206 -[[image:1652953553383-907.png||height="514" width="724"]] 207 207 275 +**Add APP KEY and DEV EUI** 208 208 277 +(% aria-label="1652953553383-907.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1652953553383-907.png||data-widget="image" height="514" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 278 + 279 + 280 + 209 209 ((( 210 -**Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 282 +(% style="color:blue" %)**Step 2**(%%): Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 283 + 284 + 211 211 ))) 212 212 213 -[[image:1652953568895-172.png||height="232" width="724"]] 287 +(% aria-label="1652953568895-172.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1652953568895-172.png||data-widget="image" height="232" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 214 214 215 215 290 + 216 216 == 3.3 Configure Commands to read data == 217 217 293 + 218 218 ((( 219 219 ((( 220 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 296 +((( 297 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-LNviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 298 + 299 + 221 221 ))) 301 +))) 222 222 223 223 ((( 224 -(% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 304 +((( 305 +(% style="color:red" %)**Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1** 306 +))) 225 225 308 + 226 226 227 227 ))) 228 228 ))) 229 229 230 -=== 3.3.1 onfigure UART settings for RS485 or TTL communication === 313 +=== 3.3.1 Configure UART settings for RS485 or TTL communication === 231 231 315 + 232 232 To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are: 233 233 234 -(% border="1" style="background-color:#ffffcc; color:green; width:782px" %) 235 -|(% style="width:128px" %)((( 318 + 319 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 320 +|=(% style="width: 110px;" %)((( 236 236 **AT Commands** 237 -)))|(% style="width: 305px" %)(((322 +)))|=(% style="width: 190px;" %)((( 238 238 **Description** 239 -)))|(% style="width: 346px" %)(((324 +)))|=(% style="width: 190px;" %)((( 240 240 **Example** 241 241 ))) 242 -|(% style="width:1 28px" %)(((327 +|(% style="width:110px" %)((( 243 243 AT+BAUDR 244 -)))|(% style="width: 305px" %)(((329 +)))|(% style="width:190px" %)((( 245 245 Set the baud rate (for RS485 connection). Default Value is: 9600. 246 -)))|(% style="width: 346px" %)(((331 +)))|(% style="width:190px" %)((( 247 247 ((( 248 248 AT+BAUDR=9600 249 249 ))) ... ... @@ -252,11 +252,11 @@ 252 252 Options: (1200,2400,4800,14400,19200,115200) 253 253 ))) 254 254 ))) 255 -|(% style="width:1 28px" %)(((340 +|(% style="width:110px" %)((( 256 256 AT+PARITY 257 -)))|(% style="width: 305px" %)(((342 +)))|(% style="width:190px" %)((( 258 258 Set UART parity (for RS485 connection) 259 -)))|(% style="width: 346px" %)(((344 +)))|(% style="width:190px" %)((( 260 260 ((( 261 261 AT+PARITY=0 262 262 ))) ... ... @@ -265,9 +265,9 @@ 265 265 Option: 0: no parity, 1: odd parity, 2: even parity 266 266 ))) 267 267 ))) 268 -|(% style="width:1 28px" %)(((353 +|(% style="width:110px" %)((( 269 269 AT+STOPBIT 270 -)))|(% style="width: 305px" %)(((355 +)))|(% style="width:190px" %)((( 271 271 ((( 272 272 Set serial stopbit (for RS485 connection) 273 273 ))) ... ... @@ -275,7 +275,7 @@ 275 275 ((( 276 276 277 277 ))) 278 -)))|(% style="width: 346px" %)(((363 +)))|(% style="width:190px" %)((( 279 279 ((( 280 280 AT+STOPBIT=0 for 1bit 281 281 ))) ... ... @@ -289,26 +289,42 @@ 289 289 ))) 290 290 ))) 291 291 377 + 378 + 379 + 292 292 === 3.3.2 Configure sensors === 293 293 382 + 294 294 ((( 295 295 ((( 296 -Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won’t run during each sampling. 385 +Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won't run during each sampling. 386 + 387 + 297 297 ))) 298 298 ))) 299 299 300 -(% border="1" style="background-color:#ffffcc; color:green; width:806px" %) 301 -|**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example** 302 -|AT+CFGDEV|(% style="width:418px" %)((( 391 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 392 +|=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 393 +|AT+CFGDEV|(% style="width:110px" %)((( 394 +((( 303 303 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 396 +))) 304 304 398 +((( 305 305 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 400 +))) 306 306 402 +((( 307 307 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 308 -)))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 404 +))) 405 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 309 309 407 + 408 + 409 + 310 310 === 3.3.3 Configure read commands for each sampling === 311 311 412 + 312 312 ((( 313 313 During each sampling, we need confirm what commands we need to send to the RS485 sensors to read data. After the RS485 sensors send back the value, it normally include some bytes and we only need a few from them for a shorten payload. 314 314 ... ... @@ -319,7 +319,7 @@ 319 319 During each sampling, the RS485-LN can support 15 commands to read sensors. And combine the return to one or several uplink payloads. 320 320 321 321 322 -**Each RS485 commands include two parts:** 423 +(% style="color:#037691" %)**Each RS485 commands include two parts:** 323 323 324 324 ~1. What commands RS485-LN will send to the RS485 sensors. There are total 15 commands from **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF**. All commands are of same grammar. 325 325 ... ... @@ -330,15 +330,14 @@ 330 330 331 331 After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**. 332 332 333 - 334 334 Below are examples for the how above AT Commands works. 335 335 336 336 337 -**AT+COMMANDx : **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is: 437 +(% style="color:#037691" %)**AT+COMMANDx **(%%)**: **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is: 338 338 339 339 (% border="1" style="background-color:#4bacc6; color:white; width:499px" %) 340 340 |(% style="width:496px" %)((( 341 -**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 441 +(% style="color:#037691" %)**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 342 342 343 343 **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent** 344 344 ... ... @@ -350,10 +350,10 @@ 350 350 In the RS485-LN, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same. 351 351 352 352 353 -**AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45bytes.453 +(% style="color:#037691" %)**AT+DATACUTx **(%%)**: **This command defines how to handle the return from AT+COMMANDx, max return length is 100 bytes. 354 354 355 -(% border="1" style="background-color:#4bacc6; color:white; width: 725px" %)356 -|(% style="width: 722px" %)(((455 +(% border="1" style="background-color:#4bacc6; color:white; width:510px" %) 456 +|(% style="width:510px" %)((( 357 357 **AT+DATACUTx=a,b,c** 358 358 359 359 * **a: length for the return of AT+COMMAND** ... ... @@ -363,25 +363,29 @@ 363 363 364 364 **Examples:** 365 365 366 -* Grab bytes :466 +* (% style="color:#037691" %)**Grab bytes** 367 367 368 -[[image:image-20220602153621-1.png]] 468 +(% aria-label="image-20220602153621-1.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602153621-1.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 369 369 370 370 371 -* Grab a section. 372 372 373 - [[image:image-20220602153621-2.png]]472 +* (% style="color:#037691" %)**Grab a section** 374 374 474 +(% aria-label="image-20220602153621-2.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602153621-2.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 375 375 376 -* Grab different sections. 377 377 378 -[[image:image-20220602153621-3.png]] 379 379 478 +* (% style="color:#037691" %)**Grab different sections** 479 + 480 +(% aria-label="image-20220602153621-3.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602153621-3.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 481 + 482 + 380 380 381 381 ))) 382 382 383 383 === 3.3.4 Compose the uplink payload === 384 384 488 + 385 385 ((( 386 386 Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.** 387 387 ... ... @@ -410,7 +410,7 @@ 410 410 Where PAYVER is defined by AT+PAYVER, below is an example screen shot. 411 411 ))) 412 412 413 -[[image:1653269759169-150.png||height="513" width="716"]] 517 +(% aria-label="1653269759169-150.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653269759169-150.png||data-widget="image" height="513" width="716"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 414 414 415 415 416 416 (% style="color:#037691" %)**Examples: AT+DATAUP=1** ... ... @@ -428,7 +428,7 @@ 428 428 1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) 429 429 1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes 430 430 431 -[[image:image-20220602155039-4.png]] 535 +(% aria-label="image-20220602155039-4.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602155039-4.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 432 432 433 433 434 434 So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA ... ... @@ -440,7 +440,7 @@ 440 440 DATA3=the rest of Valid value of RETURN10= **30** 441 441 442 442 443 -(% style="color:red" %)Notice: In firmware v1.3, the Max bytes has been changed according to the max bytes in different Frequency Bands for lowest SF. As below: 547 +(% style="color:red" %)**Notice: In firmware v1.3, the Max bytes has been changed according to the max bytes in different Frequency Bands for lowest SF. As below:** 444 444 445 445 ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink. 446 446 ... ... @@ -450,14 +450,31 @@ 450 450 451 451 ~* For all other bands: max 51 bytes for each uplink. 452 452 557 +(% style="color:red" %)*** When AT+DATAUP=1, the maximum number of segments is 15, and the maximum total number of bytes is 1500;** 453 453 559 +(% style="color:red" %)** When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value. (Since v1.4.0)** 560 + 561 + 562 +(% style="color:#4f81bd" %)**If the data is empty, return to the display(Since v1.4.0)** 563 + 564 +1)When AT+MOD=1, if the data intercepted by AT+DATACUT or AT+MBFUN is empty, it will display NULL, and the payload will be filled with n FFs. 565 + 566 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/test/WebHome/image-20220824114359-3.png?width=1106&height=297&rev=1.1||alt="image-20220824114359-3.png" height="297" width="1106"]] 567 + 568 +2)When AT+MOD=2, if the data intercepted by AT+DATACUT or AT+MBFUN is empty, it will display NULL, and the payload will be filled with n 00s. 569 + 570 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/test/WebHome/image-20220824114330-2.png?rev=1.1||alt="image-20220824114330-2.png"]] 571 + 572 + 454 454 Below are the uplink payloads: 455 455 456 -[[image:1654157178836-407.png]] 575 +(% aria-label="1654157178836-407.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654157178836-407.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 457 457 458 458 578 + 459 459 === 3.3.5 Uplink on demand === 460 460 581 + 461 461 Except uplink periodically, RS485-LN is able to uplink on demand. The server send downlink command to RS485-LN and RS485 will uplink data base on the command. 462 462 463 463 Downlink control command: ... ... @@ -470,578 +470,1070 @@ 470 470 471 471 === 3.3.6 Uplink on Interrupt === 472 472 594 + 473 473 RS485-LN support external Interrupt uplink since hardware v1.2 release. 474 474 475 -[[image:1654157342174-798.png]] 597 +(% aria-label="1654157342174-798.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654157342174-798.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 476 476 477 477 Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet. 478 478 479 479 602 + 480 480 == 3.4 Uplink Payload == 481 481 482 -(% border="1" style="background-color:#4bacc6; color:white; width:734px" %) 483 -|**Size(bytes)**|(% style="width:120px" %)**2**|(% style="width:116px" %)**1**|(% style="width:386px" %)**Length depends on the return from the commands** 484 -|Value|(% style="width:120px" %)((( 485 -Battery(mV) 486 486 487 - &606 +(% aria-label="image-20220606110929-1.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220606110929-1.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 488 488 489 -Interrupt _Flag 490 -)))|(% style="width:116px" %)((( 491 -PAYLOAD_VER 608 +Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 492 492 493 - 494 -)))|(% style="width:386px" %)If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server. 495 495 496 -Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 497 497 612 +== 3.5 Configure RS485-LN via AT or Downlink == 498 498 499 -== 3.5 Configure RS485-BL via AT or Downlink == 500 500 615 +((( 501 501 User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands 617 +))) 502 502 619 +((( 503 503 There are two kinds of Commands: 621 +))) 504 504 505 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 623 +* ((( 624 +(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 625 +))) 506 506 507 -* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN. User can see these commands below: 627 +* ((( 628 +(% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN. User can see these commands below: 629 +))) 508 508 631 +((( 632 + 633 +))) 634 + 635 + 636 + 509 509 === 3.5.1 Common Commands === 510 510 639 + 511 511 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 512 512 513 513 514 -=== 3.5.2 Sensor related commands === 515 515 644 +=== 3.5.2 Downlink Response(Since firmware v1.4) === 645 + 646 + 516 516 Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server. 517 517 518 -[[image:image-20220602163333-5.png||height="263" width="1160"]] 649 +(% aria-label="image-20220602163333-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602163333-5.png||data-widget="image" height="263" width="1160"]](% title="Click and drag to resize" %) 519 519 520 520 The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable) 521 521 522 522 654 + 523 523 === 3.5.3 Sensor related commands === 524 524 525 525 526 526 527 -==== **RS485 Debug Command** ==== 528 528 529 - ThiscommandisusedtoconfiguretheRS485devices; they won’tbeused duringsampling.660 +==== (% style="color:blue" %)**RS485 Debug Command**(%%) ==== 530 530 531 -* **AT Command** 532 532 533 -(% class="box infomessage" %) 534 534 ((( 535 - **AT+CFGDEV=xxxxxxxxxxxxxxxxxxxxxxxx,m**664 +This command is used to configure the RS485 devices; they won't be used during sampling. 536 536 ))) 537 537 538 -m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 667 +* ((( 668 +(% style="color:#037691" %)**AT Command** 539 539 540 -* **Downlink Payload** 670 +((( 671 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 672 +))) 673 +))) 541 541 675 +((( 676 + 677 +))) 678 + 679 +* ((( 680 +(% style="color:#037691" %)**Downlink Payload** 681 +))) 682 + 683 +((( 542 542 Format: A8 MM NN XX XX XX XX YY 685 +))) 543 543 687 +((( 544 544 Where: 689 +))) 545 545 546 -* MM: 1: add CRC-16/MODBUS ; 0: no CRC 547 -* NN: The length of RS485 command 548 -* XX XX XX XX: RS485 command total NN bytes 549 -* YY: How many bytes will be uplink from the return of this RS485 command, 550 -** if YY=0, RS485-LN will execute the downlink command without uplink; 551 -** if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200 552 -** if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200. 691 +* ((( 692 +MM: 1: add CRC-16/MODBUS ; 0: no CRC 693 +))) 694 +* ((( 695 +NN: The length of RS485 command 696 +))) 697 +* ((( 698 +XX XX XX XX: RS485 command total NN bytes 699 +))) 700 +* ((( 701 +((( 702 +YY: How many bytes will be uplink from the return of this RS485 command, 703 +))) 553 553 554 -**Example 1** ~-~-> Configure without ask for uplink (YY=0) 705 +* ((( 706 +if YY=0, RS485-LN will execute the downlink command without uplink; 707 +))) 708 +* ((( 709 +if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200 710 +))) 711 +* ((( 712 +if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200. 713 +))) 714 +))) 555 555 716 +((( 717 + 718 + 719 +(% style="color:blue" %)**Example 1:** (%%) ~-~-> Configure without ask for uplink (YY=0) 720 +))) 721 + 722 +((( 556 556 To connect a Modbus Alarm with below commands. 724 +))) 557 557 558 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 726 +* ((( 727 +The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 728 +))) 559 559 560 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 730 +* ((( 731 +The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 732 +))) 561 561 734 +((( 735 + 736 + 562 562 So if user want to use downlink command to control to RS485 Alarm, he can use: 738 +))) 563 563 740 +((( 564 564 (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 742 +))) 565 565 744 +((( 566 566 (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 746 +))) 567 567 748 +((( 568 568 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 750 +))) 569 569 752 +((( 753 + 754 +))) 570 570 571 -**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 756 +((( 757 +(% style="color:blue" %)**Example 2:** (%%) ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 758 +))) 572 572 760 +((( 573 573 User in IoT server send a downlink command: (% style="color:#4f81bd" %)**A8 01 06 0A 08 00 04 00 01 YY** 762 +))) 574 574 764 +((( 765 + 766 +))) 575 575 576 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: 768 +((( 769 +((( 770 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 771 +))) 577 577 578 - **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 773 + 774 +))) 579 579 580 - [[image:1654159460680-153.png]] 776 +((( 777 + (% aria-label="1654159460680-153.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654159460680-153.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 778 +))) 581 581 582 582 583 583 584 -==== **Set Payload version** ==== 585 585 586 - Thisisthe firstbyte of the uplink payload. RS485-BL can connect todifferent sensors. Usercan setthePAYVER fieldto tell serverhow to decode the currentpayload.783 +==== (% style="color:blue" %)**Set Payload version**(%%) ==== 587 587 588 -* **AT Command:** 589 589 590 -(% class="box infomessage" %) 591 591 ((( 592 - **AT+PAYVER:Set PAYVER field=1**787 +This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 593 593 ))) 594 594 595 -* **Downlink Payload:** 790 +* ((( 791 +(% style="color:#037691" %)**AT Command:** 596 596 597 -** 0xAE01**~-~->Set PAYVER field =0x01793 +**AT+PAYVER: **Set PAYVER field = 1 598 598 599 -**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 795 + 796 +))) 797 +* ((( 798 +(% style="color:#037691" %)**Downlink Payload:** 799 +))) 600 600 801 +((( 802 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 803 +))) 601 601 805 +((( 806 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 807 +))) 602 602 603 -==== **Set RS485 Sampling Commands** ==== 604 604 605 -A T+COMMANDxorAT+DATACUTx810 +1)Add the interrupt flag at the highest bit of the Payver byte, that is, Byte7 of the first byte. (Since v1.4.0)[[image:image-20220824145428-2.png||height="168" width="1300"]] 606 606 607 -These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 608 608 813 +2)if the data intercepted by AT+DATACUT or AT+MBFUN is empty, it will display NULL, and the payload will be filled with n FFs. 609 609 610 - * **AT Command:**815 +[[image:image-20220824145428-3.png||height="308" width="1200"]] 611 611 612 -(% class="box infomessage" %) 817 + 818 +==== (% style="color:blue" %)**Set RS485 Sampling Commands**(%%) ==== 819 + 820 + 613 613 ((( 614 - **AT+COMMANDx:ConfigureRS485read command to sensor.**822 +AT+COMMANDx or AT+DATACUTx 615 615 ))) 616 616 617 -(% class="box infomessage" %) 618 618 ((( 619 - **AT+DATACUTx:Configure how tohandlereturnfromRS485 devices.**826 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 620 620 ))) 621 621 829 +((( 830 + 831 +))) 622 622 623 -* **Downlink Payload:** 833 +* ((( 834 +(% style="color:#037691" %)**AT Command:** 835 +))) 624 624 837 +**AT+COMMANDx: **Configure RS485 read command to sensor. 838 + 839 +**AT+DATACUTx: **Configure how to handle return from RS485 devices. 840 + 841 + 842 +* ((( 843 +(% style="color:#037691" %)**Downlink Payload:** 844 +))) 845 + 846 +((( 625 625 **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 626 626 849 + 850 +))) 851 + 852 +((( 627 627 (% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 628 628 855 + 856 +))) 857 + 858 +((( 629 629 Format: AF MM NN LL XX XX XX XX YY 860 +))) 630 630 862 +((( 631 631 Where: 864 +))) 632 632 633 -* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 634 -* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 635 -* LL: The length of AT+COMMAND or AT+DATACUT command 636 -* XX XX XX XX: AT+COMMAND or AT+DATACUT command 637 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 866 +* ((( 867 +MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 868 +))) 869 +* ((( 870 +NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 871 +))) 872 +* ((( 873 +LL: The length of AT+COMMAND or AT+DATACUT command 874 +))) 875 +* ((( 876 +XX XX XX XX: AT+COMMAND or AT+DATACUT command 877 +))) 878 +* ((( 879 +YY: If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 880 +))) 638 638 882 +((( 883 + 884 + 639 639 **Example:** 886 +))) 640 640 888 +((( 641 641 (% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1 890 +))) 642 642 892 +((( 643 643 (% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10** 894 +))) 644 644 896 +((( 645 645 (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10** 898 +))) 646 646 647 647 648 648 649 -==== **Fast command to handle MODBUS device** ==== 650 650 651 - AT+MBFUNisvalidsincev1.3 firmware version. Thecommand is forfast configure to readModbus devices. Itisonlyvalidfor the devices which follow the[[MODBUS-RTUprotocol>>url:https://www.modbustools.com/modbus.html]].903 +==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ==== 652 652 905 + 906 +((( 907 +**AT+MBFUN** is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 908 +))) 909 + 910 +((( 653 653 This command is valid since v1.3 firmware version 912 +))) 654 654 914 +((( 655 655 AT+MBFUN can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 916 +))) 656 656 918 +((( 919 + 920 +))) 657 657 922 +((( 658 658 **Example:** 924 +))) 659 659 660 -* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 661 -* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 662 -* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 926 +* ((( 927 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 928 +))) 929 +* ((( 930 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 931 +))) 932 +* ((( 933 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 663 663 664 -[[image:image-20220602165351-6.png]] 935 + 936 +))) 665 665 666 -[[image:image-20220602165351- 7.png]]938 +(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% title="Click and drag to resize" %) 667 667 940 +(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %) 668 668 669 669 670 -==== **RS485 command timeout** ==== 671 671 944 + 945 +==== (% style="color:blue" %)**RS485 command timeout**(%%) ==== 946 + 947 + 948 +((( 672 672 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. 950 +))) 673 673 952 +((( 674 674 Default value: 0, range: 0 ~~ 65 seconds 954 +))) 675 675 676 -* **AT Command:** 956 +* ((( 957 +(% style="color:#037691" %)** AT Command:** 677 677 678 -(% class="box infomessage" %) 679 -((( 680 680 **AT+CMDDLaa=hex(bb cc)*1000** 681 681 ))) 682 682 962 +((( 963 + 964 + 683 683 **Example:** 966 +))) 684 684 968 +((( 685 685 **AT+CMDDL1=1000** to send the open time to 1000ms 970 +))) 686 686 972 +((( 973 + 974 +))) 687 687 688 -* **Downlink Payload:** 976 +* ((( 977 +(% style="color:#037691" %)** Downlink Payload:** 978 +))) 689 689 980 +((( 690 690 **0x AA aa bb cc** 982 +))) 691 691 984 +((( 692 692 Same as: AT+CMDDLaa=hex(bb cc)*1000 986 +))) 693 693 694 - **Example:** 988 +((( 989 +**Example:** 990 +))) 695 695 696 - 0xAA 01 00 01 ~-~-> Same as **AT+CMDDL1=1000 ms** 992 +((( 993 +**0xAA 01 00 01** ~-~-> Same as **AT+CMDDL1=1000 ms** 994 +))) 697 697 698 698 997 +==== (% style="color:blue" %)**Uplink payload mode**(%%) ==== 699 699 700 -==== **Uplink payload mode** ==== 701 701 1000 +((( 702 702 Define to use one uplink or multiple uplinks for the sampling. 1002 +))) 703 703 1004 +((( 704 704 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 705 705 706 -* **AT Command:** 1007 + 1008 +))) 707 707 708 -(% class="box infomessage" %) 709 -((( 1010 +* ((( 1011 +(% style="color:#037691" %)** AT Command:** 1012 + 710 710 **AT+DATAUP=0** 711 -))) 712 712 713 -(% class="box infomessage" %) 714 -((( 715 715 **AT+DATAUP=1** 1016 + 1017 + 716 716 ))) 717 717 1020 +**0xAD 01 00 00 14** **~-~->** Same as AT+DATAUP=1,20000 ~/~/(00 00 14 is 20 seconds) 718 718 719 - ***DownlinkPayload:**1022 +Each uplink is sent to the server at 20-second intervals when segmented. 720 720 721 -**0xAD 00** **~-~->** Same as AT+DATAUP=0 722 722 723 -**0xAD 01** **~-~->** Same as AT+DATAUP=1 1025 +* ((( 1026 +(% style="color:#037691" %)** Downlink Payload:** 1027 +))) 724 724 1029 +**0xAD 00** **~-~->** Same as AT+DATAUP=0 725 725 1031 +**0xAD 01** **~-~->** Same as AT+DATAUP=1 ~/~/Each uplink is sent to the server one after the other as it is segmented. 726 726 727 -==== **Manually trigger an Uplink** ==== 728 728 1034 +* ((( 1035 +(% style="color:#037691" %)** AT Command:** 1036 +))) 1037 + 1038 +**AT+DATAUP=1,Timeout** 1039 + 1040 + 1041 +* ((( 1042 +(% style="color:#037691" %)** Downlink Payload:** 1043 +))) 1044 + 1045 +**0xAD 01 00 00 14** **~-~->** Same as AT+DATAUP=1,20000 ~/~/(00 00 14 is 20 seconds) 1046 + 1047 +Each uplink is sent to the server at 20-second intervals when segmented. 1048 + 1049 +==== (% style="color:blue" %)**Manually trigger an Uplink**(%%) ==== 1050 + 1051 + 1052 +((( 729 729 Ask device to send an uplink immediately. 1054 +))) 730 730 731 -* **AT Command:** 1056 +* ((( 1057 +(% style="color:#037691" %)** AT Command:** 1058 +))) 732 732 1060 +((( 733 733 No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same. 1062 +))) 734 734 1064 +((( 1065 + 1066 +))) 735 735 736 -* **Downlink Payload:** 1068 +* ((( 1069 +(% style="color:#037691" %)** Downlink Payload:** 1070 +))) 737 737 1072 +((( 738 738 **0x08 FF**, RS485-LN will immediately send an uplink. 1074 +))) 739 739 740 740 741 741 742 -==== **Clear RS485 Command** ==== 743 743 1079 +==== (% style="color:blue" %)**Clear RS485 Command**(%%) ==== 1080 + 1081 + 1082 +((( 744 744 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 745 745 746 -* **AT Command:** 1085 + 1086 +))) 747 747 1088 +* ((( 1089 +(% style="color:#037691" %)** AT Command:** 1090 +))) 1091 + 1092 +((( 748 748 **AT+CMDEAR=mm,nn** mm: start position of erase ,nn: stop position of erase 1094 +))) 749 749 1096 +((( 750 750 Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1098 +))) 751 751 1100 +((( 752 752 Example screen shot after clear all RS485 commands. 1102 +))) 753 753 1104 +((( 1105 + 1106 +))) 754 754 1108 +((( 755 755 The uplink screen shot is: 1110 +))) 756 756 757 -[[image:1654160691922-496.png]] 1112 +(% aria-label="1654160691922-496.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654160691922-496.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 758 758 759 759 760 -* **Downlink Payload:** 1115 +* ((( 1116 +(% style="color:#037691" %)** Downlink Payload:** 1117 +))) 761 761 1119 +((( 762 762 **0x09 aa bb** same as AT+CMDEAR=aa,bb 1121 +))) 763 763 764 764 765 765 766 -==== **Set Serial Communication Parameters** ==== 767 767 1126 +==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%) ==== 1127 + 1128 + 1129 +((( 768 768 Set the Rs485 serial communication parameters: 769 769 770 -* **AT Command:** 1132 + 1133 +))) 771 771 772 -Set Baud Rate: 1135 +* ((( 1136 +(% style="color:#037691" %)** AT Command:** 1137 +))) 773 773 774 -(% class="box infomessage" %) 775 775 ((( 776 -* *AT+BAUDR=9600**~/~/ Options:(1200,2400,4800,14400,19200,115200)1140 +* Set Baud Rate 777 777 ))) 778 778 779 - SetUARTParity1143 +**AT+BAUDR=9600** ~/~/ Options: (200~~115200) When using low baud rate or receiving multiple bytes, you need to use AT+CMDDL to increase the receive timeout (the default receive timeout is 400ms), otherwise data will be lost 780 780 781 - (% class="box infomessage" %)1145 + 782 782 ((( 783 -* *AT+PARITY=0**~/~/ Option: 0: no parity, 1: odd parity, 2: even parity1147 +* Set UART Parity 784 784 ))) 785 785 786 - Set STOPBIT1150 +**AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 787 787 788 - (% class="box infomessage" %)1152 + 789 789 ((( 790 -* *AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits1154 +* Set STOPBIT 791 791 ))) 792 792 1157 +**AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 793 793 794 -* **Downlink Payload:** 795 795 796 -**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 797 797 1161 +* ((( 1162 +(% style="color:#037691" %)** Downlink Payload:** 1163 +))) 1164 + 1165 +((( 1166 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1167 +))) 1168 + 1169 +((( 798 798 **Example:** 1171 +))) 799 799 800 -* A7 01 00 60 same as AT+BAUDR=9600 801 -* A7 01 04 80 same as AT+BAUDR=115200 1173 +* ((( 1174 +A7 01 00 60 same as AT+BAUDR=9600 1175 +))) 1176 +* ((( 1177 +A7 01 04 80 same as AT+BAUDR=115200 1178 +))) 802 802 803 -A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1180 +((( 1181 +A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1182 +))) 804 804 805 -A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1184 +((( 1185 +A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1186 +))) 806 806 807 807 1189 +==== (% style="color:blue" %)**Encrypted payload**(%%) ==== 1190 + 1191 +((( 1192 + 1193 +))) 1194 + 1195 +* ((( 1196 +(% style="color:#037691" %)** AT Command:** 1197 +))) 1198 + 1199 +**AT+DECRYPT=1 **~/~/ The payload is uploaded without encryption 1200 + 1201 +**AT+DECRYPT=0 **~/~/Encrypt when uploading payload (default) 1202 + 1203 + 1204 +==== (% style="color:blue" %)**Get sensor value**(%%) ==== 1205 + 1206 + 1207 +* ((( 1208 +(% style="color:#037691" %)** AT Command:** 1209 +))) 1210 + 1211 +**AT+GETSENSORVALUE=0 **~/~/ The serial port gets the reading of the current sensor 1212 + 1213 +**AT+GETSENSORVALUE=1 **~/~/The serial port gets the current sensor reading and uploads it. 1214 + 1215 + 1216 +==== (% style="color:blue" %)**Resets the downlink packet count**(%%) ==== 1217 + 1218 + 1219 +* ((( 1220 +(% style="color:#037691" %)** AT Command:** 1221 +))) 1222 + 1223 +**AT+DISFCNTCHECK=0 **~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default) 1224 + 1225 +**AT+DISFCNTCHECK=1 **~/~/When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count. 1226 + 1227 + 1228 +==== (% style="color:blue" %)**When the limit bytes are exceeded, upload in batches**(%%) ==== 1229 + 1230 + 1231 +* ((( 1232 +(% style="color:#037691" %)** AT Command:** 1233 +))) 1234 + 1235 + **AT+DISMACANS=0** ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default) 1236 + 1237 + **AT+DISMACANS=1** ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part. 1238 + 1239 + 1240 +* ((( 1241 +(% style="color:#037691" %)** Downlink Payload:** 1242 +))) 1243 + 1244 +**0x21 00 01 ** ~/~/ Set the DISMACANS=1 1245 + 1246 + 1247 +==== (% style="color:blue" %)** Copy downlink to uplink **(%%) ==== 1248 + 1249 + 1250 +* ((( 1251 +(% style="color:#037691" %)** AT Command:** 1252 +))) 1253 + 1254 +**AT+RPL=5** ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100. 1255 + 1256 +Example:**aa xx xx xx xx** ~/~/ aa indicates whether the configuration has changed, 00 is yes, 01 is no; xx xx xx xx are the bytes sent. 1257 + 1258 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173747-6.png?width=1124&height=165&rev=1.1||alt="image-20220823173747-6.png"]] 1259 + 1260 +For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77. 1261 + 1262 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173833-7.png?width=1124&height=149&rev=1.1||alt="image-20220823173833-7.png"]] 1263 + 1264 +For example, if 01 00 02 58 is issued, a valid configuration of 01 01 00 02 58 will be returned. 1265 + 1266 + 1267 +==== (% style="color:blue" %)**Query version number and frequency band 、TDC**(%%) ==== 1268 + 1269 + 1270 +* ((( 1271 +(% style="color:#037691" %)**Downlink Payload:** 1272 + 1273 +**26 01 ** ~/~/ Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time. 1274 +))) 1275 + 1276 +Example: 1277 + 1278 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]] 1279 + 1280 +==== ==== 1281 + 1282 +==== (% style="color:blue" %)** Monitor RS485 communication of other devices**(%%) ==== 1283 + 1284 + 1285 +* ((( 1286 +(% style="color:#037691" %)** AT Command:** 1287 +))) 1288 + 1289 +**~ AT+RXMODE=1,10** ~/~/ When the RS485-LN receives more than 10 bytes from the RS485, it immediately sends the uplink of the received data. 1290 + 1291 +**~ AT+RXMODE=2,500 ** ~/~/RS485-LN uploads data as uplink from the first byte received by RS485 to the data received within 500ms after that. 1292 + 1293 + **AT+RXMODE=0,0 ** ~/~/Disable this mode (default) 1294 + 1295 + 1296 +* ((( 1297 +(% style="color:#037691" %)**Downlink Payload:** 1298 +))) 1299 + 1300 +**A6 aa bb bb ** ~/~/same as AT+RXMODE=aa,bb 1301 + 1302 +[[image:image-20220824144240-1.png]] 1303 + 1304 + 1305 + 808 808 == 3.6 Listening mode for RS485 network == 809 809 1308 + 1309 +((( 810 810 This feature support since firmware v1.4 1311 +))) 811 811 1313 +((( 812 812 RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN. 813 813 814 -[[image:image-20220602171200-8.png||height="567" width="1007"]] 1316 + 1317 +))) 815 815 1319 +(% aria-label="image-20220602171200-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602171200-8.png||data-widget="image" height="567" width="1007"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1320 + 1321 +((( 816 816 To enable the listening mode, use can run the command AT+RXMODE. 1323 +))) 817 817 1325 +((( 1326 + 1327 +))) 818 818 819 -(% border="1" style="background-color:#ffffcc; width:500px" %) 820 -|=(% style="width: 161px;" %)**Command example:**|=(% style="width: 337px;" %)**Function** 821 -|(% style="width:161px" %)AT+RXMODE=1,10 |(% style="width:337px" %)Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 822 -|(% style="width:161px" %)AT+RXMODE=2,500|(% style="width:337px" %)Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 823 -|(% style="width:161px" %)AT+RXMODE=0,0|(% style="width:337px" %)Disable listening mode. This is the default settings. 824 -|(% style="width:161px" %) |(% style="width:337px" %)A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 ~| cc) 1329 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1330 +|=(% style="width: 100px;" %)((( 1331 +**Command example** 1332 +)))|=(% style="width: 400px;" %)((( 1333 +**Function** 1334 +))) 1335 +|(% style="width:100px" %)((( 1336 +AT+RXMODE=1,10 1337 +)))|(% style="width:400px" %)((( 1338 +Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1339 +))) 1340 +|(% style="width:100px" %)((( 1341 +AT+RXMODE=2,500 1342 +)))|(% style="width:400px" %)((( 1343 +Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1344 +))) 1345 +|(% style="width:100px" %)((( 1346 +AT+RXMODE=0,0 1347 +)))|(% style="width:400px" %)((( 1348 +Disable listening mode. This is the default settings. 1349 +))) 1350 +|(% style="width:100px" %)((( 1351 + 1352 +)))|(% style="width:400px" %)((( 1353 +A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1354 +))) 825 825 826 -**Downlink Command:** 1356 +((( 1357 +(% style="color:#037691" %)** Downlink Command:** 1358 +))) 827 827 1360 +((( 828 828 **0xA6 aa bb cc ** same as AT+RXMODE=aa,(bb<<8 | cc) 1362 +))) 829 829 1364 +((( 1365 + 1366 +))) 830 830 1368 +((( 831 831 **Example**: 1370 +))) 832 832 1372 +((( 833 833 The RS485-LN is set to AT+RXMODE=2,1000 1374 +))) 834 834 1376 +((( 835 835 There is a two Modbus commands in the RS485 network as below: 1378 +))) 836 836 1380 +((( 837 837 The Modbus master send a command: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b 1382 +))) 838 838 1384 +((( 839 839 And Modbus slave reply with: (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 1386 +))) 840 840 1388 +((( 841 841 RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 1390 +))) 842 842 843 -[[image:image-20220602171200-9.png]] 1392 +((( 1393 +(% aria-label="image-20220602171200-9.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602171200-9.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1394 +))) 844 844 1396 +((( 1397 + 1398 +))) 845 845 846 -(% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1400 +((( 1401 +((( 1402 +(% style="color:red" %)**Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.** 1403 +))) 1404 +))) 847 847 848 848 1407 + 849 849 == 3.7 Buttons == 850 850 851 851 852 -(% border="1" style="background-color:#f7faff; width: 500px" %)853 -|=**Button**|=(% style="width: 1 420px;" %)**Feature**854 -|**ACT**|(% style="width:1 420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**855 -|**RST**|(% style="width:1 420px" %)Reboot RS485856 -|**PRO**|(% style="width:1 420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]1411 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1412 +|=(% style="width: 50px;" %)**Button**|=(% style="width: 361px;" %)**Feature** 1413 +|(% style="width:50px" %)**ACT**|(% style="width:361px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 1414 +|(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485 1415 +|(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 857 857 858 - 859 859 == 3.8 LEDs == 860 860 861 -(% border="1" style="background-color:#f7faff; width:500px" %) 862 -|=**LEDs**|=**Feature** 1419 + 1420 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1421 +|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature** 863 863 |**PWR**|Always on if there is power 864 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink 1423 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 865 865 866 - 867 867 = 4. Case Study = 868 868 1427 + 869 869 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] 870 870 871 871 1431 + 872 872 = 5. Use AT Command = 873 873 1434 + 874 874 == 5.1 Access AT Command == 875 875 876 -RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 877 877 878 -[[image:1654162355560-817.png]] 1438 +((( 1439 +RS485-LN supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-LN to use AT command, as below. 1440 +))) 879 879 1442 +(% aria-label="1654162355560-817.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162355560-817.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 880 880 881 -In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 882 882 883 -[[image:1654162368066-342.png]] 1445 +((( 1446 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-LN. The default password is 123456. Below is the output for reference: 1447 +))) 884 884 1449 +(% aria-label="1654162368066-342.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162368066-342.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 885 885 1451 + 1452 +((( 886 886 More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1454 +))) 887 887 888 888 1457 + 889 889 == 5.2 Common AT Command Sequence == 890 890 1460 + 891 891 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 892 892 1463 + 893 893 If device has not joined network yet: 894 894 895 -(% class="box infomessage" %) 896 -((( 897 -**AT+FDR** 898 -))) 1466 +* (% style="color:#037691" %)**AT+FDR** 1467 +* (% style="color:#037691" %)**AT+NJM=0** 1468 +* (% style="color:#037691" %)**ATZ** 899 899 900 -(% class="box infomessage" %) 901 901 ((( 902 -**AT+NJM=0** 903 -))) 1471 + 904 904 905 -(% class="box infomessage" %) 906 -((( 907 -**ATZ** 908 -))) 909 - 910 - 911 911 If device already joined network: 912 912 913 -(% class="box infomessage" %) 914 -((( 915 -**AT+NJM=0** 916 -))) 1475 +* (% style="color:#037691" %)**AT+NJM=0** 1476 +* (% style="color:#037691" %)**ATZ** 917 917 918 -(% class="box infomessage" %) 919 -((( 920 -**ATZ** 1478 + 921 921 ))) 922 922 923 923 1482 + 924 924 === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 925 925 926 926 927 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1486 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 928 928 929 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 1488 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%) Set to ABP mode 930 930 931 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 1490 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) Set the Adaptive Data Rate Off 932 932 933 -(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 1492 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) Set Data Rate 934 934 935 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1494 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 936 936 937 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1496 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 938 938 939 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1498 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 940 940 941 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1500 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 942 942 943 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1502 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 944 944 945 -(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1504 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 946 946 947 947 948 948 (% style="color:red" %)**Note:** 949 949 1509 +((( 950 950 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 951 951 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 952 952 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 953 953 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 954 954 955 -[[image:1654162478620-421.png]] 1515 + 1516 +))) 956 956 1518 +(% aria-label="1654162478620-421.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162478620-421.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 957 957 1520 + 1521 + 958 958 = 6. FAQ = 959 959 1524 + 960 960 == 6.1 How to upgrade the image? == 961 961 1527 + 1528 +((( 962 962 The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to: 1530 +))) 963 963 964 -* Support new features 965 -* For bug fix 966 -* Change LoRaWAN bands. 1532 +* ((( 1533 +Support new features 1534 +))) 1535 +* ((( 1536 +For bug fix 1537 +))) 1538 +* ((( 1539 +Change LoRaWAN bands. 1540 +))) 967 967 1542 +((( 968 968 Below shows the hardware connection for how to upload an image to RS485-LN: 1544 +))) 969 969 970 -[[image:1654162535040-878.png]] 1546 +(% aria-label="1654162535040-878.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162535040-878.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]] 971 971 972 - **Step1:**Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].1548 +(% title="Click and drag to resize" %) 973 973 974 -**Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1550 +((( 1551 +(% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1552 +))) 975 975 976 -**Step3: **Open flashloader; choose the correct COM port to update. 1554 +((( 1555 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:https://www.dropbox.com/sh/g99v0fxcltn9r1y/AACP33wo_ZQLsxW2MJ70oUoba/RS485-LN/Firmware?dl=0&subfolder_nav_tracking=1]]. 1556 +))) 977 977 978 978 ((( 1559 +(% style="color:blue" %)**Step3**(%%)**: **Open flashloader; choose the correct COM port to update. 1560 +))) 1561 + 1562 +((( 1563 +((( 1564 +((( 979 979 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 980 980 ))) 1567 +))) 1568 +))) 981 981 982 982 983 -[[image:image-20220602175818-12.png]] 1571 +(% aria-label="image-20220602175818-12.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175818-12.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 984 984 985 985 986 -[[image:image-20220602175848-13.png]] 1574 +(% aria-label="image-20220602175848-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175848-13.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 987 987 988 988 989 -[[image:image-20220602175912-14.png]] 1577 +(% aria-label="image-20220602175912-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175912-14.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 990 990 991 991 992 -**Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1580 +(% style="color:red" %)**Notice**: **In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:** 993 993 994 -[[image:image-20220602175638-10.png]] 1582 +(% aria-label="image-20220602175638-10.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175638-10.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 995 995 996 996 1585 + 997 997 == 6.2 How to change the LoRa Frequency Bands/Region? == 998 998 1588 + 999 999 User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download. 1000 1000 1001 1001 1002 -== 6.3 How many RS485-Slave can RS485-BL connects? == 1003 1003 1004 - TheRS485-BLcan supportmax 32 RS485 devices. Each uplinkcommand ofRS485-BL can support max 16 differentRS485command.SoRS485-BL can support max 16 RS485 devices pre-program inthe device for uplink. For other devices no pre-program, user can usethe [[downlink message(type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].1593 +== 6.3 How many RS485-Slave can RS485-LN connects? == 1005 1005 1006 1006 1596 +The RS485-LN can support max 32 RS485 devices. Each uplink command of RS485-LN can support max 16 different RS485 command. So RS485-LN can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 1597 + 1598 + 1599 + 1007 1007 == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? == 1008 1008 1602 + 1009 1009 When user need to use with ChirpStack or TTI. Please set AT+RPL=4. 1010 1010 1011 1011 Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]] 1012 1012 1013 1013 1608 + 1609 +== 6.5 Can i use point to point communication for RS485-LN? == 1610 + 1611 + 1612 +Yes, please refer [[Point to Point Communication for RS485-LN>>Point to Point Communication for RS485-LN]]. 1613 + 1614 + 1615 + 1616 +== 6.6 How to Use RS485-LN to connect to RS232 devices? == 1617 + 1618 + 1619 +[[Use RS485-BL or RS485-LN to connect to RS232 devices. - DRAGINO>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/RS485%20to%20RS232/]] 1620 + 1621 + 1622 + 1014 1014 = 7. Trouble Shooting = 1015 1015 1016 -== 7.1 Downlink doesn’t work, how to solve it? == 1017 1017 1626 +== 7.1 Downlink doesn't work, how to solve it? == 1627 + 1628 + 1018 1018 Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]] 1019 1019 1020 1020 1021 -== 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? == 1022 1022 1633 +== 7.2 Why I can't join TTN V3 in US915 /AU915 bands? == 1634 + 1635 + 1023 1023 It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 1024 1024 1025 1025 1639 + 1026 1026 = 8. Order Info = 1027 1027 1642 + 1028 1028 (% style="color:blue" %)**Part Number: RS485-LN-XXX** 1029 1029 1030 1030 (% style="color:blue" %)**XXX:** 1031 1031 1032 -* (% style="color: blue" %)**EU433**(%%): frequency bands EU4331033 -* (% style="color: blue" %)**EU868**(%%): frequency bands EU8681034 -* (% style="color: blue" %)**KR920**(%%): frequency bands KR9201035 -* (% style="color: blue" %)**CN470**(%%): frequency bands CN4701036 -* (% style="color: blue" %)**AS923**(%%): frequency bands AS9231037 -* (% style="color: blue" %)**AU915**(%%): frequency bands AU9151038 -* (% style="color: blue" %)**US915**(%%): frequency bands US9151039 -* (% style="color: blue" %)**IN865**(%%): frequency bands IN8651040 -* (% style="color: blue" %)**RU864**(%%): frequency bands RU8641041 -* (% style="color: blue" %)**KZ865**(%%): frequency bands KZ8651647 +* (% style="color:red" %)**EU433**(%%): frequency bands EU433 1648 +* (% style="color:red" %)**EU868**(%%): frequency bands EU868 1649 +* (% style="color:red" %)**KR920**(%%): frequency bands KR920 1650 +* (% style="color:red" %)**CN470**(%%): frequency bands CN470 1651 +* (% style="color:red" %)**AS923**(%%): frequency bands AS923 1652 +* (% style="color:red" %)**AU915**(%%): frequency bands AU915 1653 +* (% style="color:red" %)**US915**(%%): frequency bands US915 1654 +* (% style="color:red" %)**IN865**(%%): frequency bands IN865 1655 +* (% style="color:red" %)**RU864**(%%): frequency bands RU864 1656 +* (% style="color:red" %)**KZ865**(%%): frequency bands KZ865 1042 1042 1043 - 1044 - 1045 1045 = 9.Packing Info = 1046 1046 1047 1047 ... ... @@ -1058,10 +1058,9 @@ 1058 1058 * Package Size / pcs : 14.5 x 8 x 5 cm 1059 1059 * Weight / pcs : 170g 1060 1060 1061 - 1062 - 1063 1063 = 10. FCC Caution for RS485LN-US915 = 1064 1064 1676 + 1065 1065 ((( 1066 1066 Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 1067 1067 ))) ... ... @@ -1075,11 +1075,11 @@ 1075 1075 ))) 1076 1076 1077 1077 ((( 1078 -**IMPORTANT NOTE:** 1690 +(% style="color:red" %)**IMPORTANT NOTE:** 1079 1079 ))) 1080 1080 1081 1081 ((( 1082 -**Note: **This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1694 +(% style="color:red" %)**Note: **(%%)This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1083 1083 ))) 1084 1084 1085 1085 ((( ... ... @@ -1103,7 +1103,7 @@ 1103 1103 ))) 1104 1104 1105 1105 ((( 1106 -**FCC Radiation Exposure Statement:** 1718 +(% style="color:red" %)**FCC Radiation Exposure Statement:** 1107 1107 ))) 1108 1108 1109 1109 ((( ... ... @@ -1111,7 +1111,16 @@ 1111 1111 ))) 1112 1112 1113 1113 1726 + 1114 1114 = 11. Support = 1115 1115 1116 -* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1117 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]. 1729 + 1730 +* ((( 1731 +Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1732 +))) 1733 +* ((( 1734 +Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]. 1735 + 1736 + 1737 + 1738 +)))
- image-20220606110929-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.9 KB - Content
- image-20220824144240-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +110.9 KB - Content
- image-20220824145428-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.6 KB - Content
- image-20220824145428-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.7 KB - Content