Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% style="text-align:center" %) 2 -[[image:1653266934636-343.png||height="385" width="385"]] 2 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653266934636-343.png?width=385&height=385&rev=1.1||alt="1653266934636-343.png" height="385" width="385"]] 3 3 4 4 5 5 ... ... @@ -10,7 +10,59 @@ 10 10 11 11 **Table of Contents:** 12 12 13 -{{toc/}} 13 +* [[1.Introduction>>path:#H1.Introduction]] 14 +** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>path:#H1.1A0WhatisRS485-LNRS485toLoRaWANConverter]] 15 +** [[1.2 Specifications>>path:#H1.2A0Specifications]] 16 +** [[1.3 Features>>path:#H1.3Features]] 17 +** [[1.4 Applications>>path:#H1.4A0Applications]] 18 +** [[1.5 Firmware Change log>>path:#H1.5A0FirmwareChangelog]] 19 +** [[1.6 Hardware Change log>>path:#H1.6HardwareChangelog]] 20 +* [[2. Power ON Device>>path:#H2.PowerONDevice]] 21 +* [[3. Operation Mode>>path:#H3.A0OperationMode]] 22 +** [[3.1 How it works?>>path:#H3.1Howitworks3F]] 23 +** [[3.2 Example to join LoRaWAN network>>path:#H3.2ExampletojoinLoRaWANnetwork]] 24 +** [[3.3 Configure Commands to read data>>path:#H3.3ConfigureCommandstoreaddata]] 25 +*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>path:#H3.3.1onfigureUARTsettingsforRS485orTTLcommunication]] 26 +*** [[3.3.2 Configure sensors>>path:#H3.3.2Configuresensors]] 27 +*** [[3.3.3 Configure read commands for each sampling>>path:#H3.3.3Configurereadcommandsforeachsampling]] 28 +*** [[3.3.4 Compose the uplink payload>>path:#H3.3.4Composetheuplinkpayload]] 29 +*** [[3.3.5 Uplink on demand>>path:#H3.3.5Uplinkondemand]] 30 +*** [[3.3.6 Uplink on Interrupt>>path:#H3.3.6UplinkonInterrupt]] 31 +** [[3.4 Uplink Payload>>path:#H3.4UplinkPayload]] 32 +** [[3.5 Configure RS485-BL via AT or Downlink>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] 33 +*** [[3.5.1 Common Commands>>path:#H3.5.1CommonCommands]] 34 +*** [[3.5.2 Sensor related commands>>path:#H3.5.2Sensorrelatedcommands]] 35 +*** [[3.5.3 Sensor related commands>>path:#H3.5.3A0Sensorrelatedcommands]] 36 +**** [[RS485 Debug Command>>path:#HRS485DebugCommand]] 37 +**** [[Set Payload version>>path:#HSetPayloadversion]] 38 +**** [[Set RS485 Sampling Commands>>path:#HSetRS485SamplingCommands]] 39 +**** [[Fast command to handle MODBUS device>>path:#HFastcommandtohandleMODBUSdevice]] 40 +**** [[RS485 command timeout>>path:#HRS485commandtimeout]] 41 +**** [[Uplink payload mode>>path:#HUplinkpayloadmode]] 42 +**** [[Manually trigger an Uplink>>path:#HManuallytriggeranUplink]] 43 +**** [[Clear RS485 Command>>path:#HClearRS485Command]] 44 +**** [[Set Serial Communication Parameters>>path:#HSetSerialCommunicationParameters]] 45 +** [[3.6 Listening mode for RS485 network>>path:#H3.6A0ListeningmodeforRS485network]] 46 +** [[3.7 Buttons>>path:#H3.7Buttons]] 47 +** [[3.8 LEDs>>path:#H3.8LEDs]] 48 +* [[4. Case Study>>path:#H4.CaseStudy]] 49 +* [[5. Use AT Command>>path:#H5.UseATCommand]] 50 +** [[5.1 Access AT Command>>path:#H5.1AccessATCommand]] 51 +** [[5.2 Common AT Command Sequence>>path:#H5.2CommonATCommandSequence]] 52 +*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>path:#H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829]] 53 +*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>path:#H5.5.2Single-channelABPmode28UsewithLG012FLG0229]] 54 +* [[6. FAQ>>path:#H6.FAQ]] 55 +** [[6.1 How to upgrade the image?>>path:#H6.1Howtoupgradetheimage3F]] 56 +** [[6.2 How to change the LoRa Frequency Bands/Region?>>path:#H6.2HowtochangetheLoRaFrequencyBands2FRegion3F]] 57 +** [[6.3 How many RS485-Slave can RS485-BL connects?>>path:#H6.3HowmanyRS485-SlavecanRS485-BLconnects3F]] 58 +** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>path:#H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F]] 59 +* [[7. Trouble Shooting>>path:#H7.TroubleShooting]] 60 +** [[7.1 Downlink doesn’t work, how to solve it?>>path:#H7.1Downlinkdoesn2019twork2Chowtosolveit3F]] 61 +** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>path:#H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F]] 62 +* [[8. Order Info>>path:#H8.OrderInfo]] 63 +* [[9.Packing Info>>path:#H9.PackingInfo]] 64 +* [[10. FCC Caution for RS485LN-US915>>path:#H10.FCCCautionforRS485LN-US915]] 65 +* [[11. Support>>path:#H11.Support]] 14 14 15 15 16 16 ... ... @@ -42,7 +42,7 @@ 42 42 ))) 43 43 ))) 44 44 45 -[[image:1653267211009-519.png||height="419" width="724"]] 97 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653267211009-519.png?width=724&height=419&rev=1.1||alt="1653267211009-519.png" height="419" width="724"]] 46 46 47 47 48 48 == 1.2 Specifications == ... ... @@ -131,7 +131,7 @@ 131 131 Once there is power, the RS485-LN will be on. 132 132 ))) 133 133 134 -[[image:1653268091319-405.png]] 186 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268091319-405.png?rev=1.1||alt="1653268091319-405.png"]] 135 135 136 136 137 137 ))) ... ... @@ -150,7 +150,7 @@ 150 150 151 151 Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 152 152 153 -[[image:1653268155545-638.png||height="334" width="724"]] 205 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268155545-638.png?width=724&height=334&rev=1.1||alt="1653268155545-638.png" height="334" width="724"]] 154 154 155 155 156 156 ((( ... ... @@ -162,10 +162,10 @@ 162 162 485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively. 163 163 ))) 164 164 165 -[[image:1653268227651-549.png||height="592" width="720"]] 217 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268227651-549.png?width=720&height=592&rev=1.1||alt="1653268227651-549.png" height="592" width="720"]] 166 166 167 167 ((( 168 -The LG308 is already set to connect to [[TTN V3 network >> path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:220 +The LG308 is already set to connect to (% class="wikiinternallink" %)[[TTN V3 network >>url:https://www.thethingsnetwork.org/]](%%). So what we need to now is only configure the TTN V3: 169 169 ))) 170 170 171 171 ((( ... ... @@ -177,7 +177,7 @@ 177 177 ))) 178 178 ))) 179 179 180 -[[image:1652953462722-299.png]] 232 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953462722-299.png?rev=1.1||alt="1652953462722-299.png"]] 181 181 182 182 ((( 183 183 ((( ... ... @@ -189,21 +189,21 @@ 189 189 ))) 190 190 ))) 191 191 192 -[[image:image-20220519174512-1.png]] 244 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-1.png?rev=1.1||alt="image-20220519174512-1.png"]] 193 193 194 -[[image:image-20220519174512-2.png||height="323" width="720"]] 246 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-2.png?width=720&height=323&rev=1.1||alt="image-20220519174512-2.png" height="323" width="720"]] 195 195 196 -[[image:image-20220519174512-3.png||height="556" width="724"]] 248 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-3.png?width=724&height=556&rev=1.1||alt="image-20220519174512-3.png" height="556" width="724"]] 197 197 198 -[[image:image-20220519174512-4.png]] 250 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-4.png?rev=1.1||alt="image-20220519174512-4.png"]] 199 199 200 200 You can also choose to create the device manually. 201 201 202 -[[image:1652953542269-423.png||height="710" width="723"]] 254 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953542269-423.png?width=723&height=710&rev=1.1||alt="1652953542269-423.png" height="710" width="723"]] 203 203 204 204 Add APP KEY and DEV EUI 205 205 206 -[[image:1652953553383-907.png||height="514" width="724"]] 258 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953553383-907.png?width=724&height=514&rev=1.1||alt="1652953553383-907.png" height="514" width="724"]] 207 207 208 208 209 209 ((( ... ... @@ -210,7 +210,7 @@ 210 210 **Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 211 211 ))) 212 212 213 -[[image:1652953568895-172.png||height="232" width="724"]] 265 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953568895-172.png?width=724&height=232&rev=1.1||alt="1652953568895-172.png" height="232" width="724"]] 214 214 215 215 216 216 == 3.3 Configure Commands to read data == ... ... @@ -217,7 +217,7 @@ 217 217 218 218 ((( 219 219 ((( 220 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>> ||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.272 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 221 221 ))) 222 222 223 223 ((( ... ... @@ -365,17 +365,17 @@ 365 365 366 366 * Grab bytes: 367 367 368 -[[image:image-20220602153621-1.png]] 420 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-1.png?rev=1.1||alt="image-20220602153621-1.png"]] 369 369 370 370 371 371 * Grab a section. 372 372 373 -[[image:image-20220602153621-2.png]] 425 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-2.png?rev=1.1||alt="image-20220602153621-2.png"]] 374 374 375 375 376 376 * Grab different sections. 377 377 378 -[[image:image-20220602153621-3.png]] 430 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-3.png?rev=1.1||alt="image-20220602153621-3.png"]] 379 379 380 380 381 381 ))) ... ... @@ -410,7 +410,7 @@ 410 410 Where PAYVER is defined by AT+PAYVER, below is an example screen shot. 411 411 ))) 412 412 413 -[[image:1653269759169-150.png||height="513" width="716"]] 465 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653269759169-150.png?width=716&height=513&rev=1.1||alt="1653269759169-150.png" height="513" width="716"]] 414 414 415 415 416 416 (% style="color:#037691" %)**Examples: AT+DATAUP=1** ... ... @@ -428,7 +428,7 @@ 428 428 1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) 429 429 1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes 430 430 431 -[[image:image-20220602155039-4.png]] 483 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602155039-4.png?rev=1.1||alt="image-20220602155039-4.png"]] 432 432 433 433 434 434 So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA ... ... @@ -453,7 +453,7 @@ 453 453 454 454 Below are the uplink payloads: 455 455 456 -[[image:1654157178836-407.png]] 508 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157178836-407.png?rev=1.1||alt="1654157178836-407.png"]] 457 457 458 458 459 459 === 3.3.5 Uplink on demand === ... ... @@ -472,7 +472,7 @@ 472 472 473 473 RS485-LN support external Interrupt uplink since hardware v1.2 release. 474 474 475 -[[image:1654157342174-798.png]] 527 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157342174-798.png?rev=1.1||alt="1654157342174-798.png"]] 476 476 477 477 Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet. 478 478 ... ... @@ -502,13 +502,13 @@ 502 502 503 503 There are two kinds of Commands: 504 504 505 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>> doc:Main.End.WebHome]]557 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 506 506 507 507 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN. User can see these commands below: 508 508 509 509 === 3.5.1 Common Commands === 510 510 511 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>> doc:Main.End.WebHome]]563 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 512 512 513 513 514 514 === 3.5.2 Sensor related commands === ... ... @@ -515,7 +515,7 @@ 515 515 516 516 Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server. 517 517 518 -[[image:image-20220602163333-5.png||height="263" width="1160"]] 570 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602163333-5.png?width=1160&height=263&rev=1.1||alt="image-20220602163333-5.png" height="263" width="1160"]] 519 519 520 520 The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable) 521 521 ... ... @@ -577,7 +577,7 @@ 577 577 578 578 **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 579 579 580 - [[image:1654159460680-153.png]] 632 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654159460680-153.png?rev=1.1||alt="1654159460680-153.png"]] 581 581 582 582 583 583 ... ... @@ -604,7 +604,7 @@ 604 604 605 605 AT+COMMANDx or AT+DATACUTx 606 606 607 -These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>> ||anchor="H3.3.3Configurereadcommandsforeachsampling"]].659 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#H3.3.3Configurereadcommandsforeachsampling]]. 608 608 609 609 610 610 * **AT Command:** ... ... @@ -661,9 +661,9 @@ 661 661 * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 662 662 * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 663 663 664 -[[image:image-20220602165351-6.png]] 716 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-6.png?rev=1.1||alt="image-20220602165351-6.png"]] 665 665 666 -[[image:image-20220602165351-7.png]] 718 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-7.png?rev=1.1||alt="image-20220602165351-7.png"]] 667 667 668 668 669 669 ... ... @@ -701,7 +701,7 @@ 701 701 702 702 Define to use one uplink or multiple uplinks for the sampling. 703 703 704 -The use of this command please see: [[Compose Uplink payload>> ||anchor="H3.3.4Composetheuplinkpayload"]]756 +The use of this command please see: [[Compose Uplink payload>>path:#H3.3.4Composetheuplinkpayload]] 705 705 706 706 * **AT Command:** 707 707 ... ... @@ -730,7 +730,7 @@ 730 730 731 731 * **AT Command:** 732 732 733 -No AT Command for this, user can press the [[ACT button>> ||anchor="H3.7Buttons"]] for 1 second for the same.785 +No AT Command for this, user can press the [[ACT button>>path:#H3.7Buttons]] for 1 second for the same. 734 734 735 735 736 736 * **Downlink Payload:** ... ... @@ -754,7 +754,7 @@ 754 754 755 755 The uplink screen shot is: 756 756 757 -[[image:1654160691922-496.png]] 809 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654160691922-496.png?rev=1.1||alt="1654160691922-496.png"]] 758 758 759 759 760 760 * **Downlink Payload:** ... ... @@ -811,7 +811,7 @@ 811 811 812 812 RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN. 813 813 814 -[[image:image-20220602171200-8.png||height="567" width="1007"]] 866 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-8.png?width=1007&height=567&rev=1.1||alt="image-20220602171200-8.png" height="567" width="1007"]] 815 815 816 816 To enable the listening mode, use can run the command AT+RXMODE. 817 817 ... ... @@ -840,7 +840,7 @@ 840 840 841 841 RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 842 842 843 -[[image:image-20220602171200-9.png]] 895 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-9.png?rev=1.1||alt="image-20220602171200-9.png"]] 844 844 845 845 846 846 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. ... ... @@ -853,9 +853,8 @@ 853 853 |=**Button**|=(% style="width: 1420px;" %)**Feature** 854 854 |**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 855 855 |**RST**|(% style="width:1420px" %)Reboot RS485 856 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>> ||anchor="H6.1Howtoupgradetheimage3F"]]908 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#H6.1Howtoupgradetheimage3F]] 857 857 858 - 859 859 == 3.8 LEDs == 860 860 861 861 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -863,10 +863,9 @@ 863 863 |**PWR**|Always on if there is power 864 864 |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 865 865 866 - 867 867 = 4. Case Study = 868 868 869 -User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>> doc:Main.Application\:Communicate.WebHome]]919 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>path:/xwiki/bin/view/Main/Application%20Note%20%3A%20Communicate%20with%20Different%20Sensors%20-----%20RS485-LN%20%20RS485-BL/]] 870 870 871 871 872 872 = 5. Use AT Command = ... ... @@ -875,15 +875,15 @@ 875 875 876 876 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 877 877 878 -[[image:1654162355560-817.png]] 928 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162355560-817.png?rev=1.1||alt="1654162355560-817.png"]] 879 879 880 880 881 881 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 882 882 883 -[[image:1654162368066-342.png]] 933 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162368066-342.png?rev=1.1||alt="1654162368066-342.png"]] 884 884 885 885 886 -More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 936 +More detail AT Command manual can be found at [[AT Command Manual>>url:https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 887 887 888 888 889 889 == 5.2 Common AT Command Sequence == ... ... @@ -952,7 +952,7 @@ 952 952 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 953 953 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 954 954 955 -[[image:1654162478620-421.png]] 1005 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162478620-421.png?rev=1.1||alt="1654162478620-421.png"]] 956 956 957 957 958 958 = 6. FAQ = ... ... @@ -967,7 +967,7 @@ 967 967 968 968 Below shows the hardware connection for how to upload an image to RS485-LN: 969 969 970 -[[image:1654162535040-878.png]] 1020 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162535040-878.png?rev=1.1||alt="1654162535040-878.png"]] 971 971 972 972 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 973 973 ... ... @@ -980,28 +980,28 @@ 980 980 ))) 981 981 982 982 983 -[[image:image-20220602175818-12.png]] 1033 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175818-12.png?rev=1.1||alt="image-20220602175818-12.png"]] 984 984 985 985 986 -[[image:image-20220602175848-13.png]] 1036 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175848-13.png?rev=1.1||alt="image-20220602175848-13.png"]] 987 987 988 988 989 -[[image:image-20220602175912-14.png]] 1039 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175912-14.png?rev=1.1||alt="image-20220602175912-14.png"]] 990 990 991 991 992 992 **Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 993 993 994 -[[image:image-20220602175638-10.png]] 1044 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175638-10.png?rev=1.1||alt="image-20220602175638-10.png"]] 995 995 996 996 997 997 == 6.2 How to change the LoRa Frequency Bands/Region? == 998 998 999 -User can follow the introduction for [[how to upgrade image>> ||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.1049 +User can follow the introduction for [[how to upgrade image>>path:#H6.1Howtoupgradetheimage3F]]. When download the images, choose the required image file for download. 1000 1000 1001 1001 1002 1002 == 6.3 How many RS485-Slave can RS485-BL connects? == 1003 1003 1004 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>> ||anchor="H3.3.3Configurereadcommandsforeachsampling"]].1054 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#H3.3.3Configurereadcommandsforeachsampling]]. 1005 1005 1006 1006 1007 1007 == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? == ... ... @@ -1008,7 +1008,7 @@ 1008 1008 1009 1009 When user need to use with ChirpStack or TTI. Please set AT+RPL=4. 1010 1010 1011 -Detail info check this link: [[Set Packet Receiving Response Level>> doc:Main.End.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]1061 +Detail info check this link: [[Set Packet Receiving Response Level>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.23SetPacketReceivingResponseLevel]] 1012 1012 1013 1013 1014 1014 = 7. Trouble Shooting = ... ... @@ -1015,12 +1015,12 @@ 1015 1015 1016 1016 == 7.1 Downlink doesn’t work, how to solve it? == 1017 1017 1018 -Please see this link for debug: [[LoRaWAN Communication Debug>> doc:Main.LoRaWAN.WebHome]]1068 +Please see this link for debug: [[LoRaWAN Communication Debug>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/]] 1019 1019 1020 1020 1021 1021 == 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? == 1022 1022 1023 -It might about the channels mapping. Please see for detail: [[Notice of Frequency band>> doc:Main.LoRaWAN.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]1073 +It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]] 1024 1024 1025 1025 1026 1026 = 8. Order Info = ... ... @@ -1040,8 +1040,6 @@ 1040 1040 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1041 1041 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1042 1042 1043 - 1044 - 1045 1045 = 9.Packing Info = 1046 1046 1047 1047