From version < 57.33 >
edited by Xiaoling
on 2022/06/06 09:27
To version < 57.12 >
edited by Xiaoling
on 2022/06/06 08:59
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -82,6 +82,8 @@
82 82  * Automatic RF Sense and CAD with ultra-fast AFC.
83 83  * Packet engine up to 256 bytes with CRC
84 84  
85 +
86 +
85 85  == 1.3 Features ==
86 86  
87 87  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -93,6 +93,8 @@
93 93  * Support Modbus protocol
94 94  * Support Interrupt uplink (Since hardware version v1.2)
95 95  
98 +
99 +
96 96  == 1.4 Applications ==
97 97  
98 98  * Smart Buildings & Home Automation
... ... @@ -102,6 +102,8 @@
102 102  * Smart Cities
103 103  * Smart Factory
104 104  
109 +
110 +
105 105  == 1.5 Firmware Change log ==
106 106  
107 107  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -217,7 +217,7 @@
217 217  
218 218  (((
219 219  (((
220 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
226 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#AT_COMMAND]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
221 221  )))
222 222  
223 223  (((
... ... @@ -422,7 +422,6 @@
422 422  
423 423  (% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
424 424  
425 -
426 426  1. PAYVER: Defined by AT+PAYVER
427 427  1. PAYLOAD COUNT: Total how many uplinks of this sampling.
428 428  1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
... ... @@ -502,7 +502,7 @@
502 502  
503 503  There are two kinds of Commands:
504 504  
505 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
510 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
506 506  
507 507  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
508 508  
... ... @@ -730,7 +730,7 @@
730 730  
731 731  * **AT Command:**
732 732  
733 -No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same.
738 +No AT Command for this, user can press the [[ACT button>>path:#Button]] for 1 second for the same.
734 734  
735 735  
736 736  * **Downlink Payload:**
... ... @@ -754,7 +754,7 @@
754 754  
755 755  The uplink screen shot is:
756 756  
757 -[[image:1654160691922-496.png]]
762 +[[image:1654160691922-496.png]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]]
758 758  
759 759  
760 760  * **Downlink Payload:**
... ... @@ -853,9 +853,10 @@
853 853  |=**Button**|=(% style="width: 1420px;" %)**Feature**
854 854  |**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
855 855  |**RST**|(% style="width:1420px" %)Reboot RS485
856 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
861 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#upgrade_image]]
857 857  
858 858  
864 +
859 859  == 3.8 LEDs ==
860 860  
861 861  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -864,6 +864,7 @@
864 864  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
865 865  
866 866  
873 +
867 867  = 4. Case Study =
868 868  
869 869  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -883,7 +883,7 @@
883 883  [[image:1654162368066-342.png]]
884 884  
885 885  
886 -More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
893 +More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]
887 887  
888 888  
889 889  == 5.2 Common AT Command Sequence ==
... ... @@ -1038,6 +1038,8 @@
1038 1038  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1039 1039  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1040 1040  
1048 +
1049 +
1041 1041  = 9.Packing Info =
1042 1042  
1043 1043  
... ... @@ -1054,6 +1054,8 @@
1054 1054  * Package Size / pcs : 14.5 x 8 x 5 cm
1055 1055  * Weight / pcs : 170g
1056 1056  
1066 +
1067 +
1057 1057  = 10. FCC Caution for RS485LN-US915 =
1058 1058  
1059 1059  Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0