Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% style="text-align:center" %) 2 -[[image:1653266934636-343.png||height="385" width="385"]] 2 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653266934636-343.png?width=385&height=385&rev=1.1||alt="1653266934636-343.png" height="385" width="385"]] 3 3 4 4 5 5 ... ... @@ -10,7 +10,59 @@ 10 10 11 11 **Table of Contents:** 12 12 13 -{{toc/}} 13 +* [[1.Introduction>>path:#H1.Introduction]] 14 +** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>path:#H1.1A0WhatisRS485-LNRS485toLoRaWANConverter]] 15 +** [[1.2 Specifications>>path:#H1.2A0Specifications]] 16 +** [[1.3 Features>>path:#H1.3Features]] 17 +** [[1.4 Applications>>path:#H1.4A0Applications]] 18 +** [[1.5 Firmware Change log>>path:#H1.5A0FirmwareChangelog]] 19 +** [[1.6 Hardware Change log>>path:#H1.6HardwareChangelog]] 20 +* [[2. Power ON Device>>path:#H2.PowerONDevice]] 21 +* [[3. Operation Mode>>path:#H3.A0OperationMode]] 22 +** [[3.1 How it works?>>path:#H3.1Howitworks3F]] 23 +** [[3.2 Example to join LoRaWAN network>>path:#H3.2ExampletojoinLoRaWANnetwork]] 24 +** [[3.3 Configure Commands to read data>>path:#H3.3ConfigureCommandstoreaddata]] 25 +*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>path:#H3.3.1onfigureUARTsettingsforRS485orTTLcommunication]] 26 +*** [[3.3.2 Configure sensors>>path:#H3.3.2Configuresensors]] 27 +*** [[3.3.3 Configure read commands for each sampling>>path:#H3.3.3Configurereadcommandsforeachsampling]] 28 +*** [[3.3.4 Compose the uplink payload>>path:#H3.3.4Composetheuplinkpayload]] 29 +*** [[3.3.5 Uplink on demand>>path:#H3.3.5Uplinkondemand]] 30 +*** [[3.3.6 Uplink on Interrupt>>path:#H3.3.6UplinkonInterrupt]] 31 +** [[3.4 Uplink Payload>>path:#H3.4UplinkPayload]] 32 +** [[3.5 Configure RS485-BL via AT or Downlink>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] 33 +*** [[3.5.1 Common Commands>>path:#H3.5.1CommonCommands]] 34 +*** [[3.5.2 Sensor related commands>>path:#H3.5.2Sensorrelatedcommands]] 35 +*** [[3.5.3 Sensor related commands>>path:#H3.5.3A0Sensorrelatedcommands]] 36 +**** [[RS485 Debug Command>>path:#HRS485DebugCommand]] 37 +**** [[Set Payload version>>path:#HSetPayloadversion]] 38 +**** [[Set RS485 Sampling Commands>>path:#HSetRS485SamplingCommands]] 39 +**** [[Fast command to handle MODBUS device>>path:#HFastcommandtohandleMODBUSdevice]] 40 +**** [[RS485 command timeout>>path:#HRS485commandtimeout]] 41 +**** [[Uplink payload mode>>path:#HUplinkpayloadmode]] 42 +**** [[Manually trigger an Uplink>>path:#HManuallytriggeranUplink]] 43 +**** [[Clear RS485 Command>>path:#HClearRS485Command]] 44 +**** [[Set Serial Communication Parameters>>path:#HSetSerialCommunicationParameters]] 45 +** [[3.6 Listening mode for RS485 network>>path:#H3.6A0ListeningmodeforRS485network]] 46 +** [[3.7 Buttons>>path:#H3.7Buttons]] 47 +** [[3.8 LEDs>>path:#H3.8LEDs]] 48 +* [[4. Case Study>>path:#H4.CaseStudy]] 49 +* [[5. Use AT Command>>path:#H5.UseATCommand]] 50 +** [[5.1 Access AT Command>>path:#H5.1AccessATCommand]] 51 +** [[5.2 Common AT Command Sequence>>path:#H5.2CommonATCommandSequence]] 52 +*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>path:#H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829]] 53 +*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>path:#H5.5.2Single-channelABPmode28UsewithLG012FLG0229]] 54 +* [[6. FAQ>>path:#H6.FAQ]] 55 +** [[6.1 How to upgrade the image?>>path:#H6.1Howtoupgradetheimage3F]] 56 +** [[6.2 How to change the LoRa Frequency Bands/Region?>>path:#H6.2HowtochangetheLoRaFrequencyBands2FRegion3F]] 57 +** [[6.3 How many RS485-Slave can RS485-BL connects?>>path:#H6.3HowmanyRS485-SlavecanRS485-BLconnects3F]] 58 +** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>path:#H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F]] 59 +* [[7. Trouble Shooting>>path:#H7.TroubleShooting]] 60 +** [[7.1 Downlink doesn’t work, how to solve it?>>path:#H7.1Downlinkdoesn2019twork2Chowtosolveit3F]] 61 +** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>path:#H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F]] 62 +* [[8. Order Info>>path:#H8.OrderInfo]] 63 +* [[9.Packing Info>>path:#H9.PackingInfo]] 64 +* [[10. FCC Caution for RS485LN-US915>>path:#H10.FCCCautionforRS485LN-US915]] 65 +* [[11. Support>>path:#H11.Support]] 14 14 15 15 16 16 ... ... @@ -42,7 +42,7 @@ 42 42 ))) 43 43 ))) 44 44 45 -[[image:1653267211009-519.png||height="419" width="724"]] 97 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653267211009-519.png?width=724&height=419&rev=1.1||alt="1653267211009-519.png" height="419" width="724"]] 46 46 47 47 48 48 == 1.2 Specifications == ... ... @@ -131,7 +131,7 @@ 131 131 Once there is power, the RS485-LN will be on. 132 132 ))) 133 133 134 -[[image:1653268091319-405.png]] 186 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268091319-405.png?rev=1.1||alt="1653268091319-405.png"]] 135 135 136 136 137 137 ))) ... ... @@ -150,7 +150,7 @@ 150 150 151 151 Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 152 152 153 -[[image:1653268155545-638.png||height="334" width="724"]] 205 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268155545-638.png?width=724&height=334&rev=1.1||alt="1653268155545-638.png" height="334" width="724"]] 154 154 155 155 156 156 ((( ... ... @@ -162,10 +162,10 @@ 162 162 485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively. 163 163 ))) 164 164 165 -[[image:1653268227651-549.png||height="592" width="720"]] 217 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268227651-549.png?width=720&height=592&rev=1.1||alt="1653268227651-549.png" height="592" width="720"]] 166 166 167 167 ((( 168 -The LG308 is already set to connect to [[TTN V3 network >> path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:220 +The LG308 is already set to connect to (% class="wikiinternallink" %)[[TTN V3 network >>url:https://www.thethingsnetwork.org/]](%%). So what we need to now is only configure the TTN V3: 169 169 ))) 170 170 171 171 ((( ... ... @@ -177,7 +177,7 @@ 177 177 ))) 178 178 ))) 179 179 180 -[[image:1652953462722-299.png]] 232 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953462722-299.png?rev=1.1||alt="1652953462722-299.png"]] 181 181 182 182 ((( 183 183 ((( ... ... @@ -189,21 +189,21 @@ 189 189 ))) 190 190 ))) 191 191 192 -[[image:image-20220519174512-1.png]] 244 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-1.png?rev=1.1||alt="image-20220519174512-1.png"]] 193 193 194 -[[image:image-20220519174512-2.png||height="323" width="720"]] 246 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-2.png?width=720&height=323&rev=1.1||alt="image-20220519174512-2.png" height="323" width="720"]] 195 195 196 -[[image:image-20220519174512-3.png||height="556" width="724"]] 248 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-3.png?width=724&height=556&rev=1.1||alt="image-20220519174512-3.png" height="556" width="724"]] 197 197 198 -[[image:image-20220519174512-4.png]] 250 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-4.png?rev=1.1||alt="image-20220519174512-4.png"]] 199 199 200 200 You can also choose to create the device manually. 201 201 202 -[[image:1652953542269-423.png||height="710" width="723"]] 254 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953542269-423.png?width=723&height=710&rev=1.1||alt="1652953542269-423.png" height="710" width="723"]] 203 203 204 204 Add APP KEY and DEV EUI 205 205 206 -[[image:1652953553383-907.png||height="514" width="724"]] 258 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953553383-907.png?width=724&height=514&rev=1.1||alt="1652953553383-907.png" height="514" width="724"]] 207 207 208 208 209 209 ((( ... ... @@ -210,7 +210,7 @@ 210 210 **Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 211 211 ))) 212 212 213 -[[image:1652953568895-172.png||height="232" width="724"]] 265 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953568895-172.png?width=724&height=232&rev=1.1||alt="1652953568895-172.png" height="232" width="724"]] 214 214 215 215 216 216 == 3.3 Configure Commands to read data == ... ... @@ -217,7 +217,7 @@ 217 217 218 218 ((( 219 219 ((( 220 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>> ||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.272 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 221 221 ))) 222 222 223 223 ((( ... ... @@ -289,7 +289,6 @@ 289 289 ))) 290 290 ))) 291 291 292 - 293 293 === 3.3.2 Configure sensors === 294 294 295 295 ((( ... ... @@ -308,7 +308,6 @@ 308 308 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 309 309 )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 310 310 311 - 312 312 === 3.3.3 Configure read commands for each sampling === 313 313 314 314 ((( ... ... @@ -367,17 +367,17 @@ 367 367 368 368 * Grab bytes: 369 369 370 -[[image:image-20220602153621-1.png]] 420 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-1.png?rev=1.1||alt="image-20220602153621-1.png"]] 371 371 372 372 373 373 * Grab a section. 374 374 375 -[[image:image-20220602153621-2.png]] 425 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-2.png?rev=1.1||alt="image-20220602153621-2.png"]] 376 376 377 377 378 378 * Grab different sections. 379 379 380 -[[image:image-20220602153621-3.png]] 430 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-3.png?rev=1.1||alt="image-20220602153621-3.png"]] 381 381 382 382 383 383 ))) ... ... @@ -412,7 +412,7 @@ 412 412 Where PAYVER is defined by AT+PAYVER, below is an example screen shot. 413 413 ))) 414 414 415 -[[image:1653269759169-150.png||height="513" width="716"]] 465 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653269759169-150.png?width=716&height=513&rev=1.1||alt="1653269759169-150.png" height="513" width="716"]] 416 416 417 417 418 418 (% style="color:#037691" %)**Examples: AT+DATAUP=1** ... ... @@ -430,7 +430,7 @@ 430 430 1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) 431 431 1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes 432 432 433 -[[image:image-20220602155039-4.png]] 483 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602155039-4.png?rev=1.1||alt="image-20220602155039-4.png"]] 434 434 435 435 436 436 So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA ... ... @@ -455,7 +455,7 @@ 455 455 456 456 Below are the uplink payloads: 457 457 458 -[[image:1654157178836-407.png]] 508 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157178836-407.png?rev=1.1||alt="1654157178836-407.png"]] 459 459 460 460 461 461 === 3.3.5 Uplink on demand === ... ... @@ -474,7 +474,7 @@ 474 474 475 475 RS485-LN support external Interrupt uplink since hardware v1.2 release. 476 476 477 -[[image:1654157342174-798.png]] 527 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157342174-798.png?rev=1.1||alt="1654157342174-798.png"]] 478 478 479 479 Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet. 480 480 ... ... @@ -504,14 +504,13 @@ 504 504 505 505 There are two kinds of Commands: 506 506 507 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>> doc:Main.End.WebHome]]557 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 508 508 509 509 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN. User can see these commands below: 510 510 511 - 512 512 === 3.5.1 Common Commands === 513 513 514 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>> doc:Main.End.WebHome]]563 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 515 515 516 516 517 517 === 3.5.2 Sensor related commands === ... ... @@ -518,7 +518,7 @@ 518 518 519 519 Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server. 520 520 521 -[[image:image-20220602163333-5.png||height="263" width="1160"]] 570 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602163333-5.png?width=1160&height=263&rev=1.1||alt="image-20220602163333-5.png" height="263" width="1160"]] 522 522 523 523 The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable) 524 524 ... ... @@ -580,7 +580,7 @@ 580 580 581 581 **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 582 582 583 - [[image:1654159460680-153.png]] 632 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654159460680-153.png?rev=1.1||alt="1654159460680-153.png"]] 584 584 585 585 586 586 ... ... @@ -607,7 +607,7 @@ 607 607 608 608 AT+COMMANDx or AT+DATACUTx 609 609 610 -These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>> ||anchor="H3.3.3Configurereadcommandsforeachsampling"]].659 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#H3.3.3Configurereadcommandsforeachsampling]]. 611 611 612 612 613 613 * **AT Command:** ... ... @@ -664,9 +664,9 @@ 664 664 * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 665 665 * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 666 666 667 -[[image:image-20220602165351-6.png]] 716 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-6.png?rev=1.1||alt="image-20220602165351-6.png"]] 668 668 669 -[[image:image-20220602165351-7.png]] 718 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-7.png?rev=1.1||alt="image-20220602165351-7.png"]] 670 670 671 671 672 672 ... ... @@ -704,7 +704,7 @@ 704 704 705 705 Define to use one uplink or multiple uplinks for the sampling. 706 706 707 -The use of this command please see: [[Compose Uplink payload>> ||anchor="H3.3.4Composetheuplinkpayload"]]756 +The use of this command please see: [[Compose Uplink payload>>path:#H3.3.4Composetheuplinkpayload]] 708 708 709 709 * **AT Command:** 710 710 ... ... @@ -733,7 +733,7 @@ 733 733 734 734 * **AT Command:** 735 735 736 -No AT Command for this, user can press the [[ACT button>> ||anchor="H3.7Buttons"]] for 1 second for the same.785 +No AT Command for this, user can press the [[ACT button>>path:#H3.7Buttons]] for 1 second for the same. 737 737 738 738 739 739 * **Downlink Payload:** ... ... @@ -757,7 +757,7 @@ 757 757 758 758 The uplink screen shot is: 759 759 760 -[[image:1654160691922-496.png]] 809 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654160691922-496.png?rev=1.1||alt="1654160691922-496.png"]] 761 761 762 762 763 763 * **Downlink Payload:** ... ... @@ -814,7 +814,7 @@ 814 814 815 815 RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN. 816 816 817 -[[image:image-20220602171200-8.png||height="567" width="1007"]] 866 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-8.png?width=1007&height=567&rev=1.1||alt="image-20220602171200-8.png" height="567" width="1007"]] 818 818 819 819 To enable the listening mode, use can run the command AT+RXMODE. 820 820 ... ... @@ -843,7 +843,7 @@ 843 843 844 844 RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 845 845 846 -[[image:image-20220602171200-9.png]] 895 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-9.png?rev=1.1||alt="image-20220602171200-9.png"]] 847 847 848 848 849 849 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. ... ... @@ -856,7 +856,7 @@ 856 856 |=**Button**|=(% style="width: 1420px;" %)**Feature** 857 857 |**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 858 858 |**RST**|(% style="width:1420px" %)Reboot RS485 859 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#upgrade _image]]908 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#H6.1Howtoupgradetheimage3F]] 860 860 861 861 == 3.8 LEDs == 862 862 ... ... @@ -867,7 +867,7 @@ 867 867 868 868 = 4. Case Study = 869 869 870 -User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>> doc:Main.Application\:Communicate.WebHome]]919 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>path:/xwiki/bin/view/Main/Application%20Note%20%3A%20Communicate%20with%20Different%20Sensors%20-----%20RS485-LN%20%20RS485-BL/]] 871 871 872 872 873 873 = 5. Use AT Command = ... ... @@ -876,15 +876,15 @@ 876 876 877 877 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 878 878 879 -[[image:1654162355560-817.png]] 928 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162355560-817.png?rev=1.1||alt="1654162355560-817.png"]] 880 880 881 881 882 882 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 883 883 884 -[[image:1654162368066-342.png]] 933 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162368066-342.png?rev=1.1||alt="1654162368066-342.png"]] 885 885 886 886 887 -More detail AT Command manual can be found at [[AT Command Manual>> ||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]936 +More detail AT Command manual can be found at [[AT Command Manual>>url:https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 888 888 889 889 890 890 == 5.2 Common AT Command Sequence == ... ... @@ -953,7 +953,7 @@ 953 953 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 954 954 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 955 955 956 -[[image:1654162478620-421.png]] 1005 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162478620-421.png?rev=1.1||alt="1654162478620-421.png"]] 957 957 958 958 959 959 = 6. FAQ = ... ... @@ -968,7 +968,7 @@ 968 968 969 969 Below shows the hardware connection for how to upload an image to RS485-LN: 970 970 971 -[[image:1654162535040-878.png]] 1020 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162535040-878.png?rev=1.1||alt="1654162535040-878.png"]] 972 972 973 973 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 974 974 ... ... @@ -976,31 +976,33 @@ 976 976 977 977 **Step3: **Open flashloader; choose the correct COM port to update. 978 978 1028 +((( 979 979 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 1030 +))) 980 980 981 981 982 -[[image:image-20220602175818-12.png]] 1033 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175818-12.png?rev=1.1||alt="image-20220602175818-12.png"]] 983 983 984 984 985 -[[image:image-20220602175848-13.png]] 1036 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175848-13.png?rev=1.1||alt="image-20220602175848-13.png"]] 986 986 987 987 988 -[[image:image-20220602175912-14.png]] 1039 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175912-14.png?rev=1.1||alt="image-20220602175912-14.png"]] 989 989 990 990 991 991 **Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 992 992 993 -[[image:image-20220602175638-10.png]] 1044 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175638-10.png?rev=1.1||alt="image-20220602175638-10.png"]] 994 994 995 995 996 996 == 6.2 How to change the LoRa Frequency Bands/Region? == 997 997 998 -User can follow the introduction for [[how to upgrade image>> ||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.1049 +User can follow the introduction for [[how to upgrade image>>path:#H6.1Howtoupgradetheimage3F]]. When download the images, choose the required image file for download. 999 999 1000 1000 1001 1001 == 6.3 How many RS485-Slave can RS485-BL connects? == 1002 1002 1003 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>> ||anchor="H3.3.3Configurereadcommandsforeachsampling"]].1054 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#H3.3.3Configurereadcommandsforeachsampling]]. 1004 1004 1005 1005 1006 1006 == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? == ... ... @@ -1007,7 +1007,7 @@ 1007 1007 1008 1008 When user need to use with ChirpStack or TTI. Please set AT+RPL=4. 1009 1009 1010 -Detail info check this link: [[Set Packet Receiving Response Level>> doc:Main.End.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]1061 +Detail info check this link: [[Set Packet Receiving Response Level>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.23SetPacketReceivingResponseLevel]] 1011 1011 1012 1012 1013 1013 = 7. Trouble Shooting = ... ... @@ -1014,12 +1014,12 @@ 1014 1014 1015 1015 == 7.1 Downlink doesn’t work, how to solve it? == 1016 1016 1017 -Please see this link for debug: [[LoRaWAN Communication Debug>> doc:Main.LoRaWAN.WebHome]]1068 +Please see this link for debug: [[LoRaWAN Communication Debug>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/]] 1018 1018 1019 1019 1020 1020 == 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? == 1021 1021 1022 -It might about the channels mapping. Please see for detail: [[Notice of Frequency band>> doc:Main.LoRaWAN.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]1073 +It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]] 1023 1023 1024 1024 1025 1025 = 8. Order Info =