From version < 57.20 >
edited by Xiaoling
on 2022/06/06 09:12
To version < 51.5 >
edited by Xiaoling
on 2022/06/02 17:48
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -6,18 +6,12 @@
6 6  **RS485-LN – RS485 to LoRaWAN Converter User Manual**
7 7  
8 8  
9 -
10 -
11 11  **Table of Contents:**
12 12  
13 -{{toc/}}
14 14  
15 15  
16 16  
17 17  
18 -
19 -
20 -
21 21  = 1.Introduction =
22 22  
23 23  == 1.1 What is RS485-LN RS485 to LoRaWAN Converter ==
... ... @@ -80,7 +80,7 @@
80 80  * Preamble detection.
81 81  * 127 dB Dynamic Range RSSI.
82 82  * Automatic RF Sense and CAD with ultra-fast AFC.
83 -* Packet engine up to 256 bytes with CRC
77 +* Packet engine up to 256 bytes with CRC.
84 84  
85 85  == 1.3 Features ==
86 86  
... ... @@ -165,7 +165,7 @@
165 165  [[image:1653268227651-549.png||height="592" width="720"]]
166 166  
167 167  (((
168 -The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:
162 +The LG308 is already set to connect to [[TTN V3 network >>path:eu1.cloud.thethings.network/]]. So what we need to now is only configure the TTN V3:
169 169  )))
170 170  
171 171  (((
... ... @@ -217,7 +217,7 @@
217 217  
218 218  (((
219 219  (((
220 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
214 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#AT_COMMAND]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
221 221  )))
222 222  
223 223  (((
... ... @@ -289,7 +289,6 @@
289 289  )))
290 290  )))
291 291  
292 -
293 293  === 3.3.2 Configure sensors ===
294 294  
295 295  (((
... ... @@ -308,7 +308,6 @@
308 308  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
309 309  )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
310 310  
311 -
312 312  === 3.3.3 Configure read commands for each sampling ===
313 313  
314 314  (((
... ... @@ -424,7 +424,6 @@
424 424  
425 425  (% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
426 426  
427 -
428 428  1. PAYVER: Defined by AT+PAYVER
429 429  1. PAYLOAD COUNT: Total how many uplinks of this sampling.
430 430  1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
... ... @@ -504,11 +504,10 @@
504 504  
505 505  There are two kinds of Commands:
506 506  
507 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
498 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
508 508  
509 509  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
510 510  
511 -
512 512  === 3.5.1 Common Commands ===
513 513  
514 514  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -525,8 +525,8 @@
525 525  
526 526  === 3.5.3 Sensor related commands ===
527 527  
518 +==== ====
528 528  
529 -
530 530  ==== **RS485 Debug Command** ====
531 531  
532 532  This command is used to configure the RS485 devices; they won’t be used during sampling.
... ... @@ -741,6 +741,7 @@
741 741  **0x08 FF**, RS485-LN will immediately send an uplink.
742 742  
743 743  
734 +==== ====
744 744  
745 745  ==== **Clear RS485 Command** ====
746 746  
... ... @@ -976,23 +976,17 @@
976 976  
977 977  **Step3: **Open flashloader; choose the correct COM port to update.
978 978  
979 -(% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
970 +(% style="color:#037691" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
980 980  
972 +[[image:image-20220602102605-1.png]]
981 981  
982 -[[image:image-20220602175818-12.png]]
983 983  
975 +[[image:image-20220602102637-2.png]]
984 984  
985 -[[image:image-20220602175848-13.png]]
986 986  
978 +[[image:image-20220602102715-3.png]]
987 987  
988 -[[image:image-20220602175912-14.png]]
989 989  
990 -
991 -**Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
992 -
993 -[[image:image-20220602175638-10.png]]
994 -
995 -
996 996  == 6.2 How to change the LoRa Frequency Bands/Region? ==
997 997  
998 998  User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
... ... @@ -1007,11 +1007,12 @@
1007 1007  
1008 1008  When user need to use with ChirpStack or TTI. Please set AT+RPL=4.
1009 1009  
1010 -Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]
995 +Detail info check this link: [[Set Packet Receiving Response Level>>End Device AT Commands and Downlink Command||anchor="H7.23SetPacketReceivingResponseLevel"]]
1011 1011  
1012 1012  
1013 1013  = 7. Trouble Shooting =
1014 1014  
1000 +
1015 1015  == 7.1 Downlink doesn’t work, how to solve it? ==
1016 1016  
1017 1017  Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]]
... ... @@ -1024,7 +1024,7 @@
1024 1024  
1025 1025  = 8. Order Info =
1026 1026  
1027 -(% style="color:blue" %)**Part Number: RS485-LN-XXX**
1013 +(% style="color:blue" %)**Part Number: RS485-BL-XXX**
1028 1028  
1029 1029  (% style="color:blue" %)**XXX:**
1030 1030  
... ... @@ -1039,48 +1039,5 @@
1039 1039  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1040 1040  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1041 1041  
1042 -= 9.Packing Info =
1043 -
1044 -
1045 -**Package Includes**:
1046 -
1047 -* RS485-LN x 1
1048 -* Stick Antenna for LoRa RF part x 1
1049 -* Program cable x 1
1050 -
1051 -**Dimension and weight**:
1052 -
1053 -* Device Size: 13.5 x 7 x 3 cm
1054 -* Device Weight: 105g
1055 -* Package Size / pcs : 14.5 x 8 x 5 cm
1056 -* Weight / pcs : 170g
1057 -
1058 -= 10. FCC Caution for RS485LN-US915 =
1059 -
1060 -Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
1061 -
1062 -This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
1063 -
1064 -
1065 -**IMPORTANT NOTE:**
1066 -
1067 -**Note: **This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1068 -
1069 -—Reorient or relocate the receiving antenna.
1070 -
1071 -—Increase the separation between the equipment and receiver.
1072 -
1073 -—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
1074 -
1075 -—Consult the dealer or an experienced radio/TV technician for help.
1076 -
1077 -
1078 -**FCC Radiation Exposure Statement:**
1079 -
1080 -This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.
1081 -
1082 -
1083 -= 11. Support =
1084 -
1085 -* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1086 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
1028 +(% class="wikigeneratedid" %)
1029 +
image-20220602175638-10.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -85.5 KB
Content
image-20220602175743-11.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -85.5 KB
Content
image-20220602175818-12.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -102.5 KB
Content
image-20220602175848-13.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -250.9 KB
Content
image-20220602175912-14.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -176.1 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0