From version < 57.2 >
edited by Xiaoling
on 2022/06/06 08:41
To version < 57.36 >
edited by Xiaoling
on 2022/06/06 09:32
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -6,12 +6,18 @@
6 6  **RS485-LN – RS485 to LoRaWAN Converter User Manual**
7 7  
8 8  
9 +
10 +
9 9  **Table of Contents:**
10 10  
13 +{{toc/}}
11 11  
12 12  
13 13  
14 14  
18 +
19 +
20 +
15 15  = 1.Introduction =
16 16  
17 17  == 1.1 What is RS485-LN RS485 to LoRaWAN Converter ==
... ... @@ -76,8 +76,6 @@
76 76  * Automatic RF Sense and CAD with ultra-fast AFC.
77 77  * Packet engine up to 256 bytes with CRC
78 78  
79 -
80 -
81 81  == 1.3 Features ==
82 82  
83 83  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -161,7 +161,7 @@
161 161  [[image:1653268227651-549.png||height="592" width="720"]]
162 162  
163 163  (((
164 -The LG308 is already set to connect to [[TTN V3 network >>path:eu1.cloud.thethings.network/]]. So what we need to now is only configure the TTN V3:
168 +The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:
165 165  )))
166 166  
167 167  (((
... ... @@ -213,7 +213,7 @@
213 213  
214 214  (((
215 215  (((
216 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#AT_COMMAND]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
220 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
217 217  )))
218 218  
219 219  (((
... ... @@ -418,6 +418,7 @@
418 418  
419 419  (% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
420 420  
425 +
421 421  1. PAYVER: Defined by AT+PAYVER
422 422  1. PAYLOAD COUNT: Total how many uplinks of this sampling.
423 423  1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
... ... @@ -497,7 +497,7 @@
497 497  
498 498  There are two kinds of Commands:
499 499  
500 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
505 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
501 501  
502 502  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
503 503  
... ... @@ -517,8 +517,8 @@
517 517  
518 518  === 3.5.3 Sensor related commands ===
519 519  
520 -==== ====
521 521  
526 +
522 522  ==== **RS485 Debug Command** ====
523 523  
524 524  This command is used to configure the RS485 devices; they won’t be used during sampling.
... ... @@ -725,7 +725,7 @@
725 725  
726 726  * **AT Command:**
727 727  
728 -No AT Command for this, user can press the [[ACT button>>path:#Button]] for 1 second for the same.
733 +No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same.
729 729  
730 730  
731 731  * **Downlink Payload:**
... ... @@ -733,7 +733,6 @@
733 733  **0x08 FF**, RS485-LN will immediately send an uplink.
734 734  
735 735  
736 -==== ====
737 737  
738 738  ==== **Clear RS485 Command** ====
739 739  
... ... @@ -750,7 +750,7 @@
750 750  
751 751  The uplink screen shot is:
752 752  
753 -[[image:1654160691922-496.png]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]]
757 +[[image:1654160691922-496.png]]
754 754  
755 755  
756 756  * **Downlink Payload:**
... ... @@ -849,8 +849,9 @@
849 849  |=**Button**|=(% style="width: 1420px;" %)**Feature**
850 850  |**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
851 851  |**RST**|(% style="width:1420px" %)Reboot RS485
852 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#upgrade_image]]
856 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
853 853  
858 +
854 854  == 3.8 LEDs ==
855 855  
856 856  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -858,6 +858,7 @@
858 858  |**PWR**|Always on if there is power
859 859  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
860 860  
866 +
861 861  = 4. Case Study =
862 862  
863 863  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -877,7 +877,7 @@
877 877  [[image:1654162368066-342.png]]
878 878  
879 879  
880 -More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]
886 +More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
881 881  
882 882  
883 883  == 5.2 Common AT Command Sequence ==
... ... @@ -969,7 +969,9 @@
969 969  
970 970  **Step3: **Open flashloader; choose the correct COM port to update.
971 971  
978 +(((
972 972  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
980 +)))
973 973  
974 974  
975 975  [[image:image-20220602175818-12.png]]