Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Karry Zhuang on 2025/03/06 16:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% style="text-align:center" %) 2 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653266934636-343.png?width=385&height=385&rev=1.1||alt="1653266934636-343.png"height="385" width="385"]]2 +[[image:1653266934636-343.png||height="385" width="385"]] 3 3 4 4 5 5 ... ... @@ -10,59 +10,7 @@ 10 10 11 11 **Table of Contents:** 12 12 13 -* [[1.Introduction>>path:#H1.Introduction]] 14 -** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>path:#H1.1A0WhatisRS485-LNRS485toLoRaWANConverter]] 15 -** [[1.2 Specifications>>path:#H1.2A0Specifications]] 16 -** [[1.3 Features>>path:#H1.3Features]] 17 -** [[1.4 Applications>>path:#H1.4A0Applications]] 18 -** [[1.5 Firmware Change log>>path:#H1.5A0FirmwareChangelog]] 19 -** [[1.6 Hardware Change log>>path:#H1.6HardwareChangelog]] 20 -* [[2. Power ON Device>>path:#H2.PowerONDevice]] 21 -* [[3. Operation Mode>>path:#H3.A0OperationMode]] 22 -** [[3.1 How it works?>>path:#H3.1Howitworks3F]] 23 -** [[3.2 Example to join LoRaWAN network>>path:#H3.2ExampletojoinLoRaWANnetwork]] 24 -** [[3.3 Configure Commands to read data>>path:#H3.3ConfigureCommandstoreaddata]] 25 -*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>path:#H3.3.1onfigureUARTsettingsforRS485orTTLcommunication]] 26 -*** [[3.3.2 Configure sensors>>path:#H3.3.2Configuresensors]] 27 -*** [[3.3.3 Configure read commands for each sampling>>path:#H3.3.3Configurereadcommandsforeachsampling]] 28 -*** [[3.3.4 Compose the uplink payload>>path:#H3.3.4Composetheuplinkpayload]] 29 -*** [[3.3.5 Uplink on demand>>path:#H3.3.5Uplinkondemand]] 30 -*** [[3.3.6 Uplink on Interrupt>>path:#H3.3.6UplinkonInterrupt]] 31 -** [[3.4 Uplink Payload>>path:#H3.4UplinkPayload]] 32 -** [[3.5 Configure RS485-BL via AT or Downlink>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] 33 -*** [[3.5.1 Common Commands>>path:#H3.5.1CommonCommands]] 34 -*** [[3.5.2 Sensor related commands>>path:#H3.5.2Sensorrelatedcommands]] 35 -*** [[3.5.3 Sensor related commands>>path:#H3.5.3A0Sensorrelatedcommands]] 36 -**** [[RS485 Debug Command>>path:#HRS485DebugCommand]] 37 -**** [[Set Payload version>>path:#HSetPayloadversion]] 38 -**** [[Set RS485 Sampling Commands>>path:#HSetRS485SamplingCommands]] 39 -**** [[Fast command to handle MODBUS device>>path:#HFastcommandtohandleMODBUSdevice]] 40 -**** [[RS485 command timeout>>path:#HRS485commandtimeout]] 41 -**** [[Uplink payload mode>>path:#HUplinkpayloadmode]] 42 -**** [[Manually trigger an Uplink>>path:#HManuallytriggeranUplink]] 43 -**** [[Clear RS485 Command>>path:#HClearRS485Command]] 44 -**** [[Set Serial Communication Parameters>>path:#HSetSerialCommunicationParameters]] 45 -** [[3.6 Listening mode for RS485 network>>path:#H3.6A0ListeningmodeforRS485network]] 46 -** [[3.7 Buttons>>path:#H3.7Buttons]] 47 -** [[3.8 LEDs>>path:#H3.8LEDs]] 48 -* [[4. Case Study>>path:#H4.CaseStudy]] 49 -* [[5. Use AT Command>>path:#H5.UseATCommand]] 50 -** [[5.1 Access AT Command>>path:#H5.1AccessATCommand]] 51 -** [[5.2 Common AT Command Sequence>>path:#H5.2CommonATCommandSequence]] 52 -*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>path:#H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829]] 53 -*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>path:#H5.5.2Single-channelABPmode28UsewithLG012FLG0229]] 54 -* [[6. FAQ>>path:#H6.FAQ]] 55 -** [[6.1 How to upgrade the image?>>path:#H6.1Howtoupgradetheimage3F]] 56 -** [[6.2 How to change the LoRa Frequency Bands/Region?>>path:#H6.2HowtochangetheLoRaFrequencyBands2FRegion3F]] 57 -** [[6.3 How many RS485-Slave can RS485-BL connects?>>path:#H6.3HowmanyRS485-SlavecanRS485-BLconnects3F]] 58 -** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>path:#H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F]] 59 -* [[7. Trouble Shooting>>path:#H7.TroubleShooting]] 60 -** [[7.1 Downlink doesn’t work, how to solve it?>>path:#H7.1Downlinkdoesn2019twork2Chowtosolveit3F]] 61 -** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>path:#H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F]] 62 -* [[8. Order Info>>path:#H8.OrderInfo]] 63 -* [[9.Packing Info>>path:#H9.PackingInfo]] 64 -* [[10. FCC Caution for RS485LN-US915>>path:#H10.FCCCautionforRS485LN-US915]] 65 -* [[11. Support>>path:#H11.Support]] 13 +{{toc/}} 66 66 67 67 68 68 ... ... @@ -94,7 +94,7 @@ 94 94 ))) 95 95 ))) 96 96 97 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653267211009-519.png?width=724&height=419&rev=1.1||alt="1653267211009-519.png"height="419" width="724"]]45 +[[image:1653267211009-519.png||height="419" width="724"]] 98 98 99 99 100 100 == 1.2 Specifications == ... ... @@ -183,7 +183,7 @@ 183 183 Once there is power, the RS485-LN will be on. 184 184 ))) 185 185 186 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268091319-405.png?rev=1.1||alt="1653268091319-405.png"]]134 +[[image:1653268091319-405.png]] 187 187 188 188 189 189 ))) ... ... @@ -202,7 +202,7 @@ 202 202 203 203 Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 204 204 205 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268155545-638.png?width=724&height=334&rev=1.1||alt="1653268155545-638.png"height="334" width="724"]]153 +[[image:1653268155545-638.png||height="334" width="724"]] 206 206 207 207 208 208 ((( ... ... @@ -214,10 +214,10 @@ 214 214 485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively. 215 215 ))) 216 216 217 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268227651-549.png?width=720&height=592&rev=1.1||alt="1653268227651-549.png"height="592" width="720"]]165 +[[image:1653268227651-549.png||height="592" width="720"]] 218 218 219 219 ((( 220 -The LG308 is already set to connect to (% class="wikiinternallink" %)[[TTN V3 network >>url:https://www.thethingsnetwork.org/]](%%). So what we need to now is only configure the TTN V3:168 +The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3: 221 221 ))) 222 222 223 223 ((( ... ... @@ -229,7 +229,7 @@ 229 229 ))) 230 230 ))) 231 231 232 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953462722-299.png?rev=1.1||alt="1652953462722-299.png"]]180 +[[image:1652953462722-299.png]] 233 233 234 234 ((( 235 235 ((( ... ... @@ -241,21 +241,21 @@ 241 241 ))) 242 242 ))) 243 243 244 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-1.png?rev=1.1||alt="image-20220519174512-1.png"]]192 +[[image:image-20220519174512-1.png]] 245 245 246 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-2.png?width=720&height=323&rev=1.1||alt="image-20220519174512-2.png"height="323" width="720"]]194 +[[image:image-20220519174512-2.png||height="323" width="720"]] 247 247 248 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-3.png?width=724&height=556&rev=1.1||alt="image-20220519174512-3.png"height="556" width="724"]]196 +[[image:image-20220519174512-3.png||height="556" width="724"]] 249 249 250 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-4.png?rev=1.1||alt="image-20220519174512-4.png"]]198 +[[image:image-20220519174512-4.png]] 251 251 252 252 You can also choose to create the device manually. 253 253 254 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953542269-423.png?width=723&height=710&rev=1.1||alt="1652953542269-423.png"height="710" width="723"]]202 +[[image:1652953542269-423.png||height="710" width="723"]] 255 255 256 256 Add APP KEY and DEV EUI 257 257 258 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953553383-907.png?width=724&height=514&rev=1.1||alt="1652953553383-907.png"height="514" width="724"]]206 +[[image:1652953553383-907.png||height="514" width="724"]] 259 259 260 260 261 261 ((( ... ... @@ -262,7 +262,7 @@ 262 262 **Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 263 263 ))) 264 264 265 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953568895-172.png?width=724&height=232&rev=1.1||alt="1652953568895-172.png"height="232" width="724"]]213 +[[image:1652953568895-172.png||height="232" width="724"]] 266 266 267 267 268 268 == 3.3 Configure Commands to read data == ... ... @@ -269,7 +269,7 @@ 269 269 270 270 ((( 271 271 ((( 272 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>> path:#H3.5ConfigureRS485-BLviaATorDownlink]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.220 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 273 273 ))) 274 274 275 275 ((( ... ... @@ -341,7 +341,6 @@ 341 341 ))) 342 342 ))) 343 343 344 - 345 345 === 3.3.2 Configure sensors === 346 346 347 347 ((( ... ... @@ -360,7 +360,6 @@ 360 360 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 361 361 )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 362 362 363 - 364 364 === 3.3.3 Configure read commands for each sampling === 365 365 366 366 ((( ... ... @@ -419,17 +419,17 @@ 419 419 420 420 * Grab bytes: 421 421 422 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-1.png?rev=1.1||alt="image-20220602153621-1.png"]]368 +[[image:image-20220602153621-1.png]] 423 423 424 424 425 425 * Grab a section. 426 426 427 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-2.png?rev=1.1||alt="image-20220602153621-2.png"]]373 +[[image:image-20220602153621-2.png]] 428 428 429 429 430 430 * Grab different sections. 431 431 432 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-3.png?rev=1.1||alt="image-20220602153621-3.png"]]378 +[[image:image-20220602153621-3.png]] 433 433 434 434 435 435 ))) ... ... @@ -464,7 +464,7 @@ 464 464 Where PAYVER is defined by AT+PAYVER, below is an example screen shot. 465 465 ))) 466 466 467 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653269759169-150.png?width=716&height=513&rev=1.1||alt="1653269759169-150.png"height="513" width="716"]]413 +[[image:1653269759169-150.png||height="513" width="716"]] 468 468 469 469 470 470 (% style="color:#037691" %)**Examples: AT+DATAUP=1** ... ... @@ -482,7 +482,7 @@ 482 482 1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) 483 483 1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes 484 484 485 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602155039-4.png?rev=1.1||alt="image-20220602155039-4.png"]]431 +[[image:image-20220602155039-4.png]] 486 486 487 487 488 488 So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA ... ... @@ -507,7 +507,7 @@ 507 507 508 508 Below are the uplink payloads: 509 509 510 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157178836-407.png?rev=1.1||alt="1654157178836-407.png"]]456 +[[image:1654157178836-407.png]] 511 511 512 512 513 513 === 3.3.5 Uplink on demand === ... ... @@ -526,7 +526,7 @@ 526 526 527 527 RS485-LN support external Interrupt uplink since hardware v1.2 release. 528 528 529 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157342174-798.png?rev=1.1||alt="1654157342174-798.png"]]475 +[[image:1654157342174-798.png]] 530 530 531 531 Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet. 532 532 ... ... @@ -556,14 +556,13 @@ 556 556 557 557 There are two kinds of Commands: 558 558 559 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>> path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]505 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 560 560 561 561 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN. User can see these commands below: 562 562 563 - 564 564 === 3.5.1 Common Commands === 565 565 566 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>> path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]511 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 567 567 568 568 569 569 === 3.5.2 Sensor related commands === ... ... @@ -570,7 +570,7 @@ 570 570 571 571 Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server. 572 572 573 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602163333-5.png?width=1160&height=263&rev=1.1||alt="image-20220602163333-5.png"height="263" width="1160"]]518 +[[image:image-20220602163333-5.png||height="263" width="1160"]] 574 574 575 575 The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable) 576 576 ... ... @@ -632,7 +632,7 @@ 632 632 633 633 **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 634 634 635 - [[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654159460680-153.png?rev=1.1||alt="1654159460680-153.png"]]580 + [[image:1654159460680-153.png]] 636 636 637 637 638 638 ... ... @@ -659,7 +659,7 @@ 659 659 660 660 AT+COMMANDx or AT+DATACUTx 661 661 662 -These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>> path:#H3.3.3Configurereadcommandsforeachsampling]].607 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 663 663 664 664 665 665 * **AT Command:** ... ... @@ -716,9 +716,9 @@ 716 716 * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 717 717 * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 718 718 719 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-6.png?rev=1.1||alt="image-20220602165351-6.png"]]664 +[[image:image-20220602165351-6.png]] 720 720 721 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-7.png?rev=1.1||alt="image-20220602165351-7.png"]]666 +[[image:image-20220602165351-7.png]] 722 722 723 723 724 724 ... ... @@ -756,7 +756,7 @@ 756 756 757 757 Define to use one uplink or multiple uplinks for the sampling. 758 758 759 -The use of this command please see: [[Compose Uplink payload>> path:#H3.3.4Composetheuplinkpayload]]704 +The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 760 760 761 761 * **AT Command:** 762 762 ... ... @@ -785,7 +785,7 @@ 785 785 786 786 * **AT Command:** 787 787 788 -No AT Command for this, user can press the (% class="wikiinternallink" %)[[ACT button>>path:#Button]](%%)for 1 second for the same.733 +No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same. 789 789 790 790 791 791 * **Downlink Payload:** ... ... @@ -809,7 +809,7 @@ 809 809 810 810 The uplink screen shot is: 811 811 812 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654160691922-496.png?rev=1.1||alt="1654160691922-496.png"]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png||alt="file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png"]]757 +[[image:1654160691922-496.png]] 813 813 814 814 815 815 * **Downlink Payload:** ... ... @@ -866,7 +866,7 @@ 866 866 867 867 RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN. 868 868 869 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-8.png?width=1007&height=567&rev=1.1||alt="image-20220602171200-8.png"height="567" width="1007"]]814 +[[image:image-20220602171200-8.png||height="567" width="1007"]] 870 870 871 871 To enable the listening mode, use can run the command AT+RXMODE. 872 872 ... ... @@ -895,7 +895,7 @@ 895 895 896 896 RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 897 897 898 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-9.png?rev=1.1||alt="image-20220602171200-9.png"]]843 +[[image:image-20220602171200-9.png]] 899 899 900 900 901 901 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. ... ... @@ -908,8 +908,10 @@ 908 908 |=**Button**|=(% style="width: 1420px;" %)**Feature** 909 909 |**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 910 910 |**RST**|(% style="width:1420px" %)Reboot RS485 911 -|**PRO**|(% style="width:1420px" %)Use for upload image, see (% class="wikiinternallink" %)[[How to Update Image>>path:#upgrade_image]]856 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#upgrade_image]] 912 912 858 + 859 + 913 913 == 3.8 LEDs == 914 914 915 915 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -919,7 +919,7 @@ 919 919 920 920 = 4. Case Study = 921 921 922 -User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>> path:/xwiki/bin/view/Main/Application%20Note%20%3A%20Communicate%20with%20Different%20Sensors%20-----%20RS485-LN%20%20RS485-BL/]]869 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] 923 923 924 924 925 925 = 5. Use AT Command = ... ... @@ -928,15 +928,15 @@ 928 928 929 929 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 930 930 931 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162355560-817.png?rev=1.1||alt="1654162355560-817.png"]]878 +[[image:1654162355560-817.png]] 932 932 933 933 934 934 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 935 935 936 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162368066-342.png?rev=1.1||alt="1654162368066-342.png"]]883 +[[image:1654162368066-342.png]] 937 937 938 938 939 -More detail AT Command manual can be found at [[AT Command Manual>> path:#3.5ConfigureRS485-BLviaATorDownlink]]886 +More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]] 940 940 941 941 942 942 == 5.2 Common AT Command Sequence == ... ... @@ -1005,7 +1005,7 @@ 1005 1005 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1006 1006 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1007 1007 1008 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162478620-421.png?rev=1.1||alt="1654162478620-421.png"]]955 +[[image:1654162478620-421.png]] 1009 1009 1010 1010 1011 1011 = 6. FAQ = ... ... @@ -1020,7 +1020,7 @@ 1020 1020 1021 1021 Below shows the hardware connection for how to upload an image to RS485-LN: 1022 1022 1023 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162535040-878.png?rev=1.1||alt="1654162535040-878.png"]]970 +[[image:1654162535040-878.png]] 1024 1024 1025 1025 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1026 1026 ... ... @@ -1031,28 +1031,28 @@ 1031 1031 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 1032 1032 1033 1033 1034 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175818-12.png?rev=1.1||alt="image-20220602175818-12.png"]]981 +[[image:image-20220602175818-12.png]] 1035 1035 1036 1036 1037 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175848-13.png?rev=1.1||alt="image-20220602175848-13.png"]]984 +[[image:image-20220602175848-13.png]] 1038 1038 1039 1039 1040 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175912-14.png?rev=1.1||alt="image-20220602175912-14.png"]]987 +[[image:image-20220602175912-14.png]] 1041 1041 1042 1042 1043 1043 **Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1044 1044 1045 -[[image: /xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175638-10.png?rev=1.1||alt="image-20220602175638-10.png"]]992 +[[image:image-20220602175638-10.png]] 1046 1046 1047 1047 1048 1048 == 6.2 How to change the LoRa Frequency Bands/Region? == 1049 1049 1050 -User can follow the introduction for [[how to upgrade image>> path:#H6.1Howtoupgradetheimage3F]]. When download the images, choose the required image file for download.997 +User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download. 1051 1051 1052 1052 1053 1053 == 6.3 How many RS485-Slave can RS485-BL connects? == 1054 1054 1055 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>> path:#H3.3.3Configurereadcommandsforeachsampling]].1002 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 1056 1056 1057 1057 1058 1058 == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? == ... ... @@ -1059,7 +1059,7 @@ 1059 1059 1060 1060 When user need to use with ChirpStack or TTI. Please set AT+RPL=4. 1061 1061 1062 -Detail info check this link: [[Set Packet Receiving Response Level>> path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.23SetPacketReceivingResponseLevel]]1009 +Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]] 1063 1063 1064 1064 1065 1065 = 7. Trouble Shooting = ... ... @@ -1066,12 +1066,12 @@ 1066 1066 1067 1067 == 7.1 Downlink doesn’t work, how to solve it? == 1068 1068 1069 -Please see this link for debug: [[LoRaWAN Communication Debug>> path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/]]1016 +Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]] 1070 1070 1071 1071 1072 1072 == 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? == 1073 1073 1074 -It might about the channels mapping. Please see for detail: [[Notice of Frequency band>> path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]]1021 +It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 1075 1075 1076 1076 1077 1077 = 8. Order Info =