From version < 57.18 >
edited by Xiaoling
on 2022/06/06 09:09
To version < 56.1 >
edited by Xiaoling
on 2022/06/02 17:59
>
Change comment: Uploaded new attachment "image-20220602175912-14.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -6,18 +6,12 @@
6 6  **RS485-LN – RS485 to LoRaWAN Converter User Manual**
7 7  
8 8  
9 -
10 -
11 11  **Table of Contents:**
12 12  
13 -{{toc/}}
14 14  
15 15  
16 16  
17 17  
18 -
19 -
20 -
21 21  = 1.Introduction =
22 22  
23 23  == 1.1 What is RS485-LN RS485 to LoRaWAN Converter ==
... ... @@ -80,9 +80,8 @@
80 80  * Preamble detection.
81 81  * 127 dB Dynamic Range RSSI.
82 82  * Automatic RF Sense and CAD with ultra-fast AFC.
83 -* Packet engine up to 256 bytes with CRC
77 +* Packet engine up to 256 bytes with CRC.
84 84  
85 -
86 86  == 1.3 Features ==
87 87  
88 88  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -94,7 +94,6 @@
94 94  * Support Modbus protocol
95 95  * Support Interrupt uplink (Since hardware version v1.2)
96 96  
97 -
98 98  == 1.4 Applications ==
99 99  
100 100  * Smart Buildings & Home Automation
... ... @@ -104,7 +104,6 @@
104 104  * Smart Cities
105 105  * Smart Factory
106 106  
107 -
108 108  == 1.5 Firmware Change log ==
109 109  
110 110  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -168,7 +168,7 @@
168 168  [[image:1653268227651-549.png||height="592" width="720"]]
169 169  
170 170  (((
171 -The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:
162 +The LG308 is already set to connect to [[TTN V3 network >>path:eu1.cloud.thethings.network/]]. So what we need to now is only configure the TTN V3:
172 172  )))
173 173  
174 174  (((
... ... @@ -220,7 +220,7 @@
220 220  
221 221  (((
222 222  (((
223 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
214 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#AT_COMMAND]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
224 224  )))
225 225  
226 226  (((
... ... @@ -292,8 +292,6 @@
292 292  )))
293 293  )))
294 294  
295 -
296 -
297 297  === 3.3.2 Configure sensors ===
298 298  
299 299  (((
... ... @@ -312,8 +312,6 @@
312 312  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
313 313  )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
314 314  
315 -
316 -
317 317  === 3.3.3 Configure read commands for each sampling ===
318 318  
319 319  (((
... ... @@ -429,7 +429,6 @@
429 429  
430 430  (% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
431 431  
432 -
433 433  1. PAYVER: Defined by AT+PAYVER
434 434  1. PAYLOAD COUNT: Total how many uplinks of this sampling.
435 435  1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
... ... @@ -509,12 +509,10 @@
509 509  
510 510  There are two kinds of Commands:
511 511  
512 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
498 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
513 513  
514 514  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
515 515  
516 -
517 -
518 518  === 3.5.1 Common Commands ===
519 519  
520 520  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -531,8 +531,8 @@
531 531  
532 532  === 3.5.3 Sensor related commands ===
533 533  
518 +==== ====
534 534  
535 -
536 536  ==== **RS485 Debug Command** ====
537 537  
538 538  This command is used to configure the RS485 devices; they won’t be used during sampling.
... ... @@ -747,6 +747,7 @@
747 747  **0x08 FF**, RS485-LN will immediately send an uplink.
748 748  
749 749  
734 +==== ====
750 750  
751 751  ==== **Clear RS485 Command** ====
752 752  
... ... @@ -864,7 +864,6 @@
864 864  |**RST**|(% style="width:1420px" %)Reboot RS485
865 865  |**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#upgrade_image]]
866 866  
867 -
868 868  == 3.8 LEDs ==
869 869  
870 870  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -872,7 +872,6 @@
872 872  |**PWR**|Always on if there is power
873 873  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
874 874  
875 -
876 876  = 4. Case Study =
877 877  
878 878  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -986,16 +986,14 @@
986 986  
987 987  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
988 988  
972 +[[image:image-20220602102605-1.png]]
989 989  
990 -[[image:image-20220602175818-12.png]]
991 991  
975 +[[image:image-20220602102637-2.png]]
992 992  
993 -[[image:image-20220602175848-13.png]]
994 994  
978 +[[image:image-20220602102715-3.png]]
995 995  
996 -[[image:image-20220602175912-14.png]]
997 -
998 -
999 999  **Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1000 1000  
1001 1001  [[image:image-20220602175638-10.png]]
... ... @@ -1047,7 +1047,6 @@
1047 1047  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1048 1048  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1049 1049  
1050 -
1051 1051  = 9.Packing Info =
1052 1052  
1053 1053  
... ... @@ -1064,7 +1064,6 @@
1064 1064  * Package Size / pcs : 14.5 x 8 x 5 cm
1065 1065  * Weight / pcs : 170g
1066 1066  
1067 -
1068 1068  = 10. FCC Caution for RS485LN-US915 =
1069 1069  
1070 1070  Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0