From version < 57.16 >
edited by Xiaoling
on 2022/06/06 09:06
To version < 57.37 >
edited by Xiaoling
on 2022/06/06 09:34
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -82,7 +82,6 @@
82 82  * Automatic RF Sense and CAD with ultra-fast AFC.
83 83  * Packet engine up to 256 bytes with CRC
84 84  
85 -
86 86  == 1.3 Features ==
87 87  
88 88  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -94,7 +94,6 @@
94 94  * Support Modbus protocol
95 95  * Support Interrupt uplink (Since hardware version v1.2)
96 96  
97 -
98 98  == 1.4 Applications ==
99 99  
100 100  * Smart Buildings & Home Automation
... ... @@ -104,7 +104,6 @@
104 104  * Smart Cities
105 105  * Smart Factory
106 106  
107 -
108 108  == 1.5 Firmware Change log ==
109 109  
110 110  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -292,8 +292,6 @@
292 292  )))
293 293  )))
294 294  
295 -
296 -
297 297  === 3.3.2 Configure sensors ===
298 298  
299 299  (((
... ... @@ -312,8 +312,6 @@
312 312  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
313 313  )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
314 314  
315 -
316 -
317 317  === 3.3.3 Configure read commands for each sampling ===
318 318  
319 319  (((
... ... @@ -509,7 +509,7 @@
509 509  
510 510  There are two kinds of Commands:
511 511  
512 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
505 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
513 513  
514 514  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
515 515  
... ... @@ -737,7 +737,7 @@
737 737  
738 738  * **AT Command:**
739 739  
740 -No AT Command for this, user can press the [[ACT button>>path:#Button]] for 1 second for the same.
733 +No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same.
741 741  
742 742  
743 743  * **Downlink Payload:**
... ... @@ -761,7 +761,7 @@
761 761  
762 762  The uplink screen shot is:
763 763  
764 -[[image:1654160691922-496.png]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]]
757 +[[image:1654160691922-496.png]]
765 765  
766 766  
767 767  * **Downlink Payload:**
... ... @@ -860,7 +860,7 @@
860 860  |=**Button**|=(% style="width: 1420px;" %)**Feature**
861 861  |**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
862 862  |**RST**|(% style="width:1420px" %)Reboot RS485
863 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#upgrade_image]]
856 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
864 864  
865 865  
866 866  == 3.8 LEDs ==
... ... @@ -890,7 +890,7 @@
890 890  [[image:1654162368066-342.png]]
891 891  
892 892  
893 -More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]
886 +More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
894 894  
895 895  
896 896  == 5.2 Common AT Command Sequence ==
... ... @@ -982,7 +982,9 @@
982 982  
983 983  **Step3: **Open flashloader; choose the correct COM port to update.
984 984  
978 +(((
985 985  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
980 +)))
986 986  
987 987  
988 988  [[image:image-20220602175818-12.png]]
... ... @@ -1046,6 +1046,7 @@
1046 1046  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1047 1047  
1048 1048  
1044 +
1049 1049  = 9.Packing Info =
1050 1050  
1051 1051  
... ... @@ -1062,7 +1062,6 @@
1062 1062  * Package Size / pcs : 14.5 x 8 x 5 cm
1063 1063  * Weight / pcs : 170g
1064 1064  
1065 -
1066 1066  = 10. FCC Caution for RS485LN-US915 =
1067 1067  
1068 1068  Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.