... ... @@ -1,5 +1,5 @@
1 1  (% style="text-align:center" %)
2 -[[image:1653266934636-343.png||height="385" width="385"]]
2 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653266934636-343.png?width=385&height=385&rev=1.1||alt="1653266934636-343.png" height="385" width="385"]]
3 3  
4 4  
5 5  
... ... @@ -10,7 +10,59 @@
10 10  
11 11  **Table of Contents:**
12 12  
13 -{{toc/}}
13 +* [[1.Introduction>>path:#H1.Introduction]]
14 +** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>path:#H1.1A0WhatisRS485-LNRS485toLoRaWANConverter]]
15 +** [[1.2 Specifications>>path:#H1.2A0Specifications]]
16 +** [[1.3 Features>>path:#H1.3Features]]
17 +** [[1.4 Applications>>path:#H1.4A0Applications]]
18 +** [[1.5 Firmware Change log>>path:#H1.5A0FirmwareChangelog]]
19 +** [[1.6 Hardware Change log>>path:#H1.6HardwareChangelog]]
20 +* [[2. Power ON Device>>path:#H2.PowerONDevice]]
21 +* [[3. Operation Mode>>path:#H3.A0OperationMode]]
22 +** [[3.1 How it works?>>path:#H3.1Howitworks3F]]
23 +** [[3.2 Example to join LoRaWAN network>>path:#H3.2ExampletojoinLoRaWANnetwork]]
24 +** [[3.3 Configure Commands to read data>>path:#H3.3ConfigureCommandstoreaddata]]
25 +*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>path:#H3.3.1onfigureUARTsettingsforRS485orTTLcommunication]]
26 +*** [[3.3.2 Configure sensors>>path:#H3.3.2Configuresensors]]
27 +*** [[3.3.3 Configure read commands for each sampling>>path:#H3.3.3Configurereadcommandsforeachsampling]]
28 +*** [[3.3.4 Compose the uplink payload>>path:#H3.3.4Composetheuplinkpayload]]
29 +*** [[3.3.5 Uplink on demand>>path:#H3.3.5Uplinkondemand]]
30 +*** [[3.3.6 Uplink on Interrupt>>path:#H3.3.6UplinkonInterrupt]]
31 +** [[3.4 Uplink Payload>>path:#H3.4UplinkPayload]]
32 +** [[3.5 Configure RS485-BL via AT or Downlink>>path:#H3.5ConfigureRS485-BLviaATorDownlink]]
33 +*** [[3.5.1 Common Commands>>path:#H3.5.1CommonCommands]]
34 +*** [[3.5.2 Sensor related commands>>path:#H3.5.2Sensorrelatedcommands]]
35 +*** [[3.5.3 Sensor related commands>>path:#H3.5.3A0Sensorrelatedcommands]]
36 +**** [[RS485 Debug Command>>path:#HRS485DebugCommand]]
37 +**** [[Set Payload version>>path:#HSetPayloadversion]]
38 +**** [[Set RS485 Sampling Commands>>path:#HSetRS485SamplingCommands]]
39 +**** [[Fast command to handle MODBUS device>>path:#HFastcommandtohandleMODBUSdevice]]
40 +**** [[RS485 command timeout>>path:#HRS485commandtimeout]]
41 +**** [[Uplink payload mode>>path:#HUplinkpayloadmode]]
42 +**** [[Manually trigger an Uplink>>path:#HManuallytriggeranUplink]]
43 +**** [[Clear RS485 Command>>path:#HClearRS485Command]]
44 +**** [[Set Serial Communication Parameters>>path:#HSetSerialCommunicationParameters]]
45 +** [[3.6 Listening mode for RS485 network>>path:#H3.6A0ListeningmodeforRS485network]]
46 +** [[3.7 Buttons>>path:#H3.7Buttons]]
47 +** [[3.8 LEDs>>path:#H3.8LEDs]]
48 +* [[4. Case Study>>path:#H4.CaseStudy]]
49 +* [[5. Use AT Command>>path:#H5.UseATCommand]]
50 +** [[5.1 Access AT Command>>path:#H5.1AccessATCommand]]
51 +** [[5.2 Common AT Command Sequence>>path:#H5.2CommonATCommandSequence]]
52 +*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>path:#H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829]]
53 +*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>path:#H5.5.2Single-channelABPmode28UsewithLG012FLG0229]]
54 +* [[6. FAQ>>path:#H6.FAQ]]
55 +** [[6.1 How to upgrade the image?>>path:#H6.1Howtoupgradetheimage3F]]
56 +** [[6.2 How to change the LoRa Frequency Bands/Region?>>path:#H6.2HowtochangetheLoRaFrequencyBands2FRegion3F]]
57 +** [[6.3 How many RS485-Slave can RS485-BL connects?>>path:#H6.3HowmanyRS485-SlavecanRS485-BLconnects3F]]
58 +** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>path:#H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F]]
59 +* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
60 +** [[7.1 Downlink doesn’t work, how to solve it?>>path:#H7.1Downlinkdoesn2019twork2Chowtosolveit3F]]
61 +** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>path:#H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F]]
62 +* [[8. Order Info>>path:#H8.OrderInfo]]
63 +* [[9.Packing Info>>path:#H9.PackingInfo]]
64 +* [[10. FCC Caution for RS485LN-US915>>path:#H10.FCCCautionforRS485LN-US915]]
65 +* [[11. Support>>path:#H11.Support]]
14 14  
15 15  
16 16  
... ... @@ -42,7 +42,7 @@
42 42  )))
43 43  )))
44 44  
45 -[[image:1653267211009-519.png||height="419" width="724"]]
97 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653267211009-519.png?width=724&height=419&rev=1.1||alt="1653267211009-519.png" height="419" width="724"]]
46 46  
47 47  
48 48  == 1.2 Specifications ==
... ... @@ -82,7 +82,6 @@
82 82  * Automatic RF Sense and CAD with ultra-fast AFC.
83 83  * Packet engine up to 256 bytes with CRC
84 84  
85 -
86 86  == 1.3 Features ==
87 87  
88 88  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -94,7 +94,6 @@
94 94  * Support Modbus protocol
95 95  * Support Interrupt uplink (Since hardware version v1.2)
96 96  
97 -
98 98  == 1.4 Applications ==
99 99  
100 100  * Smart Buildings & Home Automation
... ... @@ -104,7 +104,6 @@
104 104  * Smart Cities
105 105  * Smart Factory
106 106  
107 -
108 108  == 1.5 Firmware Change log ==
109 109  
110 110  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -134,7 +134,7 @@
134 134  Once there is power, the RS485-LN will be on.
135 135  )))
136 136  
137 -[[image:1653268091319-405.png]]
186 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268091319-405.png?rev=1.1||alt="1653268091319-405.png"]]
138 138  
139 139  
140 140  )))
... ... @@ -153,7 +153,7 @@
153 153  
154 154  Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
155 155  
156 -[[image:1653268155545-638.png||height="334" width="724"]]
205 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268155545-638.png?width=724&height=334&rev=1.1||alt="1653268155545-638.png" height="334" width="724"]]
157 157  
158 158  
159 159  (((
... ... @@ -165,10 +165,10 @@
165 165  485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively.
166 166  )))
167 167  
168 -[[image:1653268227651-549.png||height="592" width="720"]]
217 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268227651-549.png?width=720&height=592&rev=1.1||alt="1653268227651-549.png" height="592" width="720"]]
169 169  
170 170  (((
171 -The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:
220 +The LG308 is already set to connect to (% class="wikiinternallink" %)[[TTN V3 network >>url:https://www.thethingsnetwork.org/]](%%). So what we need to now is only configure the TTN V3:
172 172  )))
173 173  
174 174  (((
... ... @@ -180,7 +180,7 @@
180 180  )))
181 181  )))
182 182  
183 -[[image:1652953462722-299.png]]
232 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953462722-299.png?rev=1.1||alt="1652953462722-299.png"]]
184 184  
185 185  (((
186 186  (((
... ... @@ -192,21 +192,21 @@
192 192  )))
193 193  )))
194 194  
195 -[[image:image-20220519174512-1.png]]
244 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-1.png?rev=1.1||alt="image-20220519174512-1.png"]]
196 196  
197 -[[image:image-20220519174512-2.png||height="323" width="720"]]
246 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-2.png?width=720&height=323&rev=1.1||alt="image-20220519174512-2.png" height="323" width="720"]]
198 198  
199 -[[image:image-20220519174512-3.png||height="556" width="724"]]
248 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-3.png?width=724&height=556&rev=1.1||alt="image-20220519174512-3.png" height="556" width="724"]]
200 200  
201 -[[image:image-20220519174512-4.png]]
250 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-4.png?rev=1.1||alt="image-20220519174512-4.png"]]
202 202  
203 203  You can also choose to create the device manually.
204 204  
205 -[[image:1652953542269-423.png||height="710" width="723"]]
254 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953542269-423.png?width=723&height=710&rev=1.1||alt="1652953542269-423.png" height="710" width="723"]]
206 206  
207 207  Add APP KEY and DEV EUI
208 208  
209 -[[image:1652953553383-907.png||height="514" width="724"]]
258 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953553383-907.png?width=724&height=514&rev=1.1||alt="1652953553383-907.png" height="514" width="724"]]
210 210  
211 211  
212 212  (((
... ... @@ -213,7 +213,7 @@
213 213  **Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
214 214  )))
215 215  
216 -[[image:1652953568895-172.png||height="232" width="724"]]
265 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953568895-172.png?width=724&height=232&rev=1.1||alt="1652953568895-172.png" height="232" width="724"]]
217 217  
218 218  
219 219  == 3.3 Configure Commands to read data ==
... ... @@ -220,7 +220,7 @@
220 220  
221 221  (((
222 222  (((
223 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
272 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
224 224  )))
225 225  
226 226  (((
... ... @@ -292,8 +292,6 @@
292 292  )))
293 293  )))
294 294  
295 -
296 -
297 297  === 3.3.2 Configure sensors ===
298 298  
299 299  (((
... ... @@ -312,8 +312,6 @@
312 312  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
313 313  )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
314 314  
315 -
316 -
317 317  === 3.3.3 Configure read commands for each sampling ===
318 318  
319 319  (((
... ... @@ -372,17 +372,17 @@
372 372  
373 373  * Grab bytes:
374 374  
375 -[[image:image-20220602153621-1.png]]
420 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-1.png?rev=1.1||alt="image-20220602153621-1.png"]]
376 376  
377 377  
378 378  * Grab a section.
379 379  
380 -[[image:image-20220602153621-2.png]]
425 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-2.png?rev=1.1||alt="image-20220602153621-2.png"]]
381 381  
382 382  
383 383  * Grab different sections.
384 384  
385 -[[image:image-20220602153621-3.png]]
430 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-3.png?rev=1.1||alt="image-20220602153621-3.png"]]
386 386  
387 387  
388 388  )))
... ... @@ -417,7 +417,7 @@
417 417  Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
418 418  )))
419 419  
420 -[[image:1653269759169-150.png||height="513" width="716"]]
465 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653269759169-150.png?width=716&height=513&rev=1.1||alt="1653269759169-150.png" height="513" width="716"]]
421 421  
422 422  
423 423  (% style="color:#037691" %)**Examples: AT+DATAUP=1**
... ... @@ -435,7 +435,7 @@
435 435  1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
436 436  1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes
437 437  
438 -[[image:image-20220602155039-4.png]]
483 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602155039-4.png?rev=1.1||alt="image-20220602155039-4.png"]]
439 439  
440 440  
441 441  So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA
... ... @@ -460,7 +460,7 @@
460 460  
461 461  Below are the uplink payloads:
462 462  
463 -[[image:1654157178836-407.png]]
508 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157178836-407.png?rev=1.1||alt="1654157178836-407.png"]]
464 464  
465 465  
466 466  === 3.3.5 Uplink on demand ===
... ... @@ -479,7 +479,7 @@
479 479  
480 480  RS485-LN support external Interrupt uplink since hardware v1.2 release.
481 481  
482 -[[image:1654157342174-798.png]]
527 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157342174-798.png?rev=1.1||alt="1654157342174-798.png"]]
483 483  
484 484  Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet.
485 485  
... ... @@ -509,13 +509,13 @@
509 509  
510 510  There are two kinds of Commands:
511 511  
512 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
557 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
513 513  
514 514  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
515 515  
516 516  === 3.5.1 Common Commands ===
517 517  
518 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
563 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
519 519  
520 520  
521 521  === 3.5.2 Sensor related commands ===
... ... @@ -522,7 +522,7 @@
522 522  
523 523  Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server.
524 524  
525 -[[image:image-20220602163333-5.png||height="263" width="1160"]]
570 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602163333-5.png?width=1160&height=263&rev=1.1||alt="image-20220602163333-5.png" height="263" width="1160"]]
526 526  
527 527  The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable)
528 528  
... ... @@ -584,7 +584,7 @@
584 584  
585 585   **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
586 586  
587 - [[image:1654159460680-153.png]]
632 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654159460680-153.png?rev=1.1||alt="1654159460680-153.png"]]
588 588  
589 589  
590 590  
... ... @@ -611,7 +611,7 @@
611 611  
612 612  AT+COMMANDx or AT+DATACUTx
613 613  
614 -These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
659 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#H3.3.3Configurereadcommandsforeachsampling]].
615 615  
616 616  
617 617  * **AT Command:**
... ... @@ -668,9 +668,9 @@
668 668  * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
669 669  * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
670 670  
671 -[[image:image-20220602165351-6.png]]
716 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-6.png?rev=1.1||alt="image-20220602165351-6.png"]]
672 672  
673 -[[image:image-20220602165351-7.png]]
718 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-7.png?rev=1.1||alt="image-20220602165351-7.png"]]
674 674  
675 675  
676 676  
... ... @@ -708,7 +708,7 @@
708 708  
709 709  Define to use one uplink or multiple uplinks for the sampling.
710 710  
711 -The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
756 +The use of this command please see: [[Compose Uplink payload>>path:#H3.3.4Composetheuplinkpayload]]
712 712  
713 713  * **AT Command:**
714 714  
... ... @@ -737,7 +737,7 @@
737 737  
738 738  * **AT Command:**
739 739  
740 -No AT Command for this, user can press the [[ACT button>>path:#Button]] for 1 second for the same.
785 +No AT Command for this, user can press the [[ACT button>>path:#H3.7Buttons]] for 1 second for the same.
741 741  
742 742  
743 743  * **Downlink Payload:**
... ... @@ -761,7 +761,7 @@
761 761  
762 762  The uplink screen shot is:
763 763  
764 -[[image:1654160691922-496.png]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]]
809 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654160691922-496.png?rev=1.1||alt="1654160691922-496.png"]]
765 765  
766 766  
767 767  * **Downlink Payload:**
... ... @@ -818,7 +818,7 @@
818 818  
819 819  RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN.
820 820  
821 -[[image:image-20220602171200-8.png||height="567" width="1007"]]
866 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-8.png?width=1007&height=567&rev=1.1||alt="image-20220602171200-8.png" height="567" width="1007"]]
822 822  
823 823  To enable the listening mode, use can run the command AT+RXMODE.
824 824  
... ... @@ -847,7 +847,7 @@
847 847  
848 848  RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b  (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33
849 849  
850 -[[image:image-20220602171200-9.png]]
895 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-9.png?rev=1.1||alt="image-20220602171200-9.png"]]
851 851  
852 852  
853 853  (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
... ... @@ -860,9 +860,8 @@
860 860  |=**Button**|=(% style="width: 1420px;" %)**Feature**
861 861  |**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
862 862  |**RST**|(% style="width:1420px" %)Reboot RS485
863 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#upgrade_image]]
908 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#H6.1Howtoupgradetheimage3F]]
864 864  
865 -
866 866  == 3.8 LEDs ==
867 867  
868 868  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -870,10 +870,9 @@
870 870  |**PWR**|Always on if there is power
871 871  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
872 872  
873 -
874 874  = 4. Case Study =
875 875  
876 -User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
919 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>path:/xwiki/bin/view/Main/Application%20Note%20%3A%20Communicate%20with%20Different%20Sensors%20-----%20RS485-LN%20%20RS485-BL/]]
877 877  
878 878  
879 879  = 5. Use AT Command =
... ... @@ -882,15 +882,15 @@
882 882  
883 883  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
884 884  
885 -[[image:1654162355560-817.png]]
928 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162355560-817.png?rev=1.1||alt="1654162355560-817.png"]]
886 886  
887 887  
888 888  In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
889 889  
890 -[[image:1654162368066-342.png]]
933 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162368066-342.png?rev=1.1||alt="1654162368066-342.png"]]
891 891  
892 892  
893 -More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]
936 +More detail AT Command manual can be found at [[AT Command Manual>>url:https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
894 894  
895 895  
896 896  == 5.2 Common AT Command Sequence ==
... ... @@ -959,7 +959,7 @@
959 959  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
960 960  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
961 961  
962 -[[image:1654162478620-421.png]]
1005 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162478620-421.png?rev=1.1||alt="1654162478620-421.png"]]
963 963  
964 964  
965 965  = 6. FAQ =
... ... @@ -974,7 +974,7 @@
974 974  
975 975  Below shows the hardware connection for how to upload an image to RS485-LN:
976 976  
977 -[[image:1654162535040-878.png]]
1020 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162535040-878.png?rev=1.1||alt="1654162535040-878.png"]]
978 978  
979 979  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
980 980  
... ... @@ -982,31 +982,33 @@
982 982  
983 983  **Step3: **Open flashloader; choose the correct COM port to update.
984 984  
1028 +(((
985 985  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1030 +)))
986 986  
987 987  
988 -[[image:image-20220602175818-12.png]]
1033 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175818-12.png?rev=1.1||alt="image-20220602175818-12.png"]]
989 989  
990 990  
991 -[[image:image-20220602175848-13.png]]
1036 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175848-13.png?rev=1.1||alt="image-20220602175848-13.png"]]
992 992  
993 993  
994 -[[image:image-20220602175912-14.png]]
1039 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175912-14.png?rev=1.1||alt="image-20220602175912-14.png"]]
995 995  
996 996  
997 997  **Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
998 998  
999 -[[image:image-20220602175638-10.png]]
1044 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175638-10.png?rev=1.1||alt="image-20220602175638-10.png"]]
1000 1000  
1001 1001  
1002 1002  == 6.2 How to change the LoRa Frequency Bands/Region? ==
1003 1003  
1004 -User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
1049 +User can follow the introduction for [[how to upgrade image>>path:#H6.1Howtoupgradetheimage3F]]. When download the images, choose the required image file for download.
1005 1005  
1006 1006  
1007 1007  == 6.3 How many RS485-Slave can RS485-BL connects? ==
1008 1008  
1009 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1054 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#H3.3.3Configurereadcommandsforeachsampling]].
1010 1010  
1011 1011  
1012 1012  == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==
... ... @@ -1013,7 +1013,7 @@
1013 1013  
1014 1014  When user need to use with ChirpStack or TTI. Please set AT+RPL=4.
1015 1015  
1016 -Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]
1061 +Detail info check this link: [[Set Packet Receiving Response Level>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.23SetPacketReceivingResponseLevel]]
1017 1017  
1018 1018  
1019 1019  = 7. Trouble Shooting =
... ... @@ -1020,12 +1020,12 @@
1020 1020  
1021 1021  == 7.1 Downlink doesn’t work, how to solve it? ==
1022 1022  
1023 -Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]]
1068 +Please see this link for debug: [[LoRaWAN Communication Debug>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/]]
1024 1024  
1025 1025  
1026 1026  == 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? ==
1027 1027  
1028 -It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1073 +It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]]
1029 1029  
1030 1030  
1031 1031  = 8. Order Info =
... ... @@ -1045,7 +1045,6 @@
1045 1045  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1046 1046  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1047 1047  
1048 -
1049 1049  = 9.Packing Info =
1050 1050  
1051 1051  
... ... @@ -1062,7 +1062,6 @@
1062 1062  * Package Size / pcs : 14.5 x 8 x 5 cm
1063 1063  * Weight / pcs : 170g
1064 1064  
1065 -
1066 1066  = 10. FCC Caution for RS485LN-US915 =
1067 1067  
1068 1068  Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0