Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Karry Zhuang on 2025/03/06 16:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -82,7 +82,6 @@ 82 82 * Automatic RF Sense and CAD with ultra-fast AFC. 83 83 * Packet engine up to 256 bytes with CRC 84 84 85 - 86 86 == 1.3 Features == 87 87 88 88 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -94,7 +94,6 @@ 94 94 * Support Modbus protocol 95 95 * Support Interrupt uplink (Since hardware version v1.2) 96 96 97 - 98 98 == 1.4 Applications == 99 99 100 100 * Smart Buildings & Home Automation ... ... @@ -104,7 +104,6 @@ 104 104 * Smart Cities 105 105 * Smart Factory 106 106 107 - 108 108 == 1.5 Firmware Change log == 109 109 110 110 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -292,8 +292,6 @@ 292 292 ))) 293 293 ))) 294 294 295 - 296 - 297 297 === 3.3.2 Configure sensors === 298 298 299 299 ((( ... ... @@ -312,8 +312,6 @@ 312 312 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 313 313 )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 314 314 315 - 316 - 317 317 === 3.3.3 Configure read commands for each sampling === 318 318 319 319 ((( ... ... @@ -429,6 +429,7 @@ 429 429 430 430 (% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA** 431 431 425 + 432 432 1. PAYVER: Defined by AT+PAYVER 433 433 1. PAYLOAD COUNT: Total how many uplinks of this sampling. 434 434 1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) ... ... @@ -508,7 +508,7 @@ 508 508 509 509 There are two kinds of Commands: 510 510 511 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[ End DeviceAT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]505 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 512 512 513 513 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN. User can see these commands below: 514 514 ... ... @@ -736,7 +736,7 @@ 736 736 737 737 * **AT Command:** 738 738 739 -No AT Command for this, user can press the [[ACT button>> path:#Button]] for 1 second for the same.733 +No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same. 740 740 741 741 742 742 * **Downlink Payload:** ... ... @@ -760,7 +760,7 @@ 760 760 761 761 The uplink screen shot is: 762 762 763 -[[image:1654160691922-496.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]]757 +[[image:1654160691922-496.png]] 764 764 765 765 766 766 * **Downlink Payload:** ... ... @@ -859,7 +859,7 @@ 859 859 |=**Button**|=(% style="width: 1420px;" %)**Feature** 860 860 |**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 861 861 |**RST**|(% style="width:1420px" %)Reboot RS485 862 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>> path:#upgrade_image]]856 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 863 863 864 864 865 865 == 3.8 LEDs == ... ... @@ -889,7 +889,7 @@ 889 889 [[image:1654162368066-342.png]] 890 890 891 891 892 -More detail AT Command manual can be found at [[AT Command Manual>> ||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]886 +More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 893 893 894 894 895 895 == 5.2 Common AT Command Sequence == ... ... @@ -981,7 +981,9 @@ 981 981 982 982 **Step3: **Open flashloader; choose the correct COM port to update. 983 983 978 +((( 984 984 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 980 +))) 985 985 986 986 987 987 [[image:image-20220602175818-12.png]] ... ... @@ -1045,6 +1045,7 @@ 1045 1045 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1046 1046 1047 1047 1044 + 1048 1048 = 9.Packing Info = 1049 1049 1050 1050 ... ... @@ -1061,7 +1061,6 @@ 1061 1061 * Package Size / pcs : 14.5 x 8 x 5 cm 1062 1062 * Weight / pcs : 170g 1063 1063 1064 - 1065 1065 = 10. FCC Caution for RS485LN-US915 = 1066 1066 1067 1067 Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.