<
From version < 57.13 >
edited by Xiaoling
on 2022/06/06 09:01
To version < 55.1 >
edited by Xiaoling
on 2022/06/02 17:58
>
Change comment: Uploaded new attachment "image-20220602175848-13.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -6,18 +6,12 @@
6 6  **RS485-LN – RS485 to LoRaWAN Converter User Manual**
7 7  
8 8  
9 -
10 -
11 11  **Table of Contents:**
12 12  
13 -{{toc/}}
14 14  
15 15  
16 16  
17 17  
18 -
19 -
20 -
21 21  = 1.Introduction =
22 22  
23 23  == 1.1 What is RS485-LN RS485 to LoRaWAN Converter ==
... ... @@ -80,9 +80,8 @@
80 80  * Preamble detection.
81 81  * 127 dB Dynamic Range RSSI.
82 82  * Automatic RF Sense and CAD with ultra-fast AFC.
83 -* Packet engine up to 256 bytes with CRC
77 +* Packet engine up to 256 bytes with CRC.
84 84  
85 -
86 86  == 1.3 Features ==
87 87  
88 88  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -94,7 +94,6 @@
94 94  * Support Modbus protocol
95 95  * Support Interrupt uplink (Since hardware version v1.2)
96 96  
97 -
98 98  == 1.4 Applications ==
99 99  
100 100  * Smart Buildings & Home Automation
... ... @@ -104,7 +104,6 @@
104 104  * Smart Cities
105 105  * Smart Factory
106 106  
107 -
108 108  == 1.5 Firmware Change log ==
109 109  
110 110  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -168,7 +168,7 @@
168 168  [[image:1653268227651-549.png||height="592" width="720"]]
169 169  
170 170  (((
171 -The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:
162 +The LG308 is already set to connect to [[TTN V3 network >>path:eu1.cloud.thethings.network/]]. So what we need to now is only configure the TTN V3:
172 172  )))
173 173  
174 174  (((
... ... @@ -220,7 +220,7 @@
220 220  
221 221  (((
222 222  (((
223 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
214 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#AT_COMMAND]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
224 224  )))
225 225  
226 226  (((
... ... @@ -524,8 +524,8 @@
524 524  
525 525  === 3.5.3 Sensor related commands ===
526 526  
518 +==== ====
527 527  
528 -
529 529  ==== **RS485 Debug Command** ====
530 530  
531 531  This command is used to configure the RS485 devices; they won’t be used during sampling.
... ... @@ -740,6 +740,7 @@
740 740  **0x08 FF**, RS485-LN will immediately send an uplink.
741 741  
742 742  
734 +==== ====
743 743  
744 744  ==== **Clear RS485 Command** ====
745 745  
... ... @@ -857,7 +857,6 @@
857 857  |**RST**|(% style="width:1420px" %)Reboot RS485
858 858  |**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#upgrade_image]]
859 859  
860 -
861 861  == 3.8 LEDs ==
862 862  
863 863  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -865,7 +865,6 @@
865 865  |**PWR**|Always on if there is power
866 866  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
867 867  
868 -
869 869  = 4. Case Study =
870 870  
871 871  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -979,16 +979,14 @@
979 979  
980 980  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
981 981  
972 +[[image:image-20220602102605-1.png]]
982 982  
983 -[[image:image-20220602175818-12.png]]
984 984  
975 +[[image:image-20220602102637-2.png]]
985 985  
986 -[[image:image-20220602175848-13.png]]
987 987  
978 +[[image:image-20220602102715-3.png]]
988 988  
989 -[[image:image-20220602175912-14.png]]
990 -
991 -
992 992  **Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
993 993  
994 994  [[image:image-20220602175638-10.png]]
... ... @@ -1040,7 +1040,6 @@
1040 1040  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1041 1041  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1042 1042  
1043 -
1044 1044  = 9.Packing Info =
1045 1045  
1046 1046  
... ... @@ -1057,7 +1057,6 @@
1057 1057  * Package Size / pcs : 14.5 x 8 x 5 cm
1058 1058  * Weight / pcs : 170g
1059 1059  
1060 -
1061 1061  = 10. FCC Caution for RS485LN-US915 =
1062 1062  
1063 1063  Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
image-20220602175912-14.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -176.1 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0