Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Karry Zhuang on 2025/03/06 16:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -82,8 +82,6 @@ 82 82 * Automatic RF Sense and CAD with ultra-fast AFC. 83 83 * Packet engine up to 256 bytes with CRC 84 84 85 - 86 - 87 87 == 1.3 Features == 88 88 89 89 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -95,8 +95,6 @@ 95 95 * Support Modbus protocol 96 96 * Support Interrupt uplink (Since hardware version v1.2) 97 97 98 - 99 - 100 100 == 1.4 Applications == 101 101 102 102 * Smart Buildings & Home Automation ... ... @@ -106,8 +106,6 @@ 106 106 * Smart Cities 107 107 * Smart Factory 108 108 109 - 110 - 111 111 == 1.5 Firmware Change log == 112 112 113 113 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -223,7 +223,7 @@ 223 223 224 224 ((( 225 225 ((( 226 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>> path:#AT_COMMAND]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.220 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 227 227 ))) 228 228 229 229 ((( ... ... @@ -428,6 +428,7 @@ 428 428 429 429 (% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA** 430 430 425 + 431 431 1. PAYVER: Defined by AT+PAYVER 432 432 1. PAYLOAD COUNT: Total how many uplinks of this sampling. 433 433 1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) ... ... @@ -507,7 +507,7 @@ 507 507 508 508 There are two kinds of Commands: 509 509 510 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[ End DeviceAT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]505 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 511 511 512 512 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN. User can see these commands below: 513 513 ... ... @@ -527,8 +527,6 @@ 527 527 528 528 === 3.5.3 Sensor related commands === 529 529 530 -(% class="wikigeneratedid" id="H" %) 531 - 532 532 533 533 534 534 ==== **RS485 Debug Command** ==== ... ... @@ -737,7 +737,7 @@ 737 737 738 738 * **AT Command:** 739 739 740 -No AT Command for this, user can press the [[ACT button>> path:#Button]] for 1 second for the same.733 +No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same. 741 741 742 742 743 743 * **Downlink Payload:** ... ... @@ -745,8 +745,6 @@ 745 745 **0x08 FF**, RS485-LN will immediately send an uplink. 746 746 747 747 748 -(% class="wikigeneratedid" id="H-1" %) 749 - 750 750 751 751 ==== **Clear RS485 Command** ==== 752 752 ... ... @@ -763,7 +763,7 @@ 763 763 764 764 The uplink screen shot is: 765 765 766 -[[image:1654160691922-496.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]]757 +[[image:1654160691922-496.png]] 767 767 768 768 769 769 * **Downlink Payload:** ... ... @@ -862,7 +862,7 @@ 862 862 |=**Button**|=(% style="width: 1420px;" %)**Feature** 863 863 |**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 864 864 |**RST**|(% style="width:1420px" %)Reboot RS485 865 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>> path:#upgrade_image]]856 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 866 866 867 867 868 868 ... ... @@ -894,7 +894,7 @@ 894 894 [[image:1654162368066-342.png]] 895 895 896 896 897 -More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]] 888 +More detail AT Command manual can be found at [[AT Command Manual>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] 898 898 899 899 900 900 == 5.2 Common AT Command Sequence == ... ... @@ -1049,8 +1049,6 @@ 1049 1049 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1050 1050 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1051 1051 1052 - 1053 - 1054 1054 = 9.Packing Info = 1055 1055 1056 1056 ... ... @@ -1067,8 +1067,6 @@ 1067 1067 * Package Size / pcs : 14.5 x 8 x 5 cm 1068 1068 * Weight / pcs : 170g 1069 1069 1070 - 1071 - 1072 1072 = 10. FCC Caution for RS485LN-US915 = 1073 1073 1074 1074 Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.