From version < 57.1 >
edited by Xiaoling
on 2022/06/02 18:02
To version < 57.14 >
edited by Xiaoling
on 2022/06/06 09:05
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -6,12 +6,18 @@
6 6  **RS485-LN – RS485 to LoRaWAN Converter User Manual**
7 7  
8 8  
9 +
10 +
9 9  **Table of Contents:**
10 10  
13 +{{toc/}}
11 11  
12 12  
13 13  
14 14  
18 +
19 +
20 +
15 15  = 1.Introduction =
16 16  
17 17  == 1.1 What is RS485-LN RS485 to LoRaWAN Converter ==
... ... @@ -74,8 +74,9 @@
74 74  * Preamble detection.
75 75  * 127 dB Dynamic Range RSSI.
76 76  * Automatic RF Sense and CAD with ultra-fast AFC.
77 -* Packet engine up to 256 bytes with CRC.
83 +* Packet engine up to 256 bytes with CRC
78 78  
85 +
79 79  == 1.3 Features ==
80 80  
81 81  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -87,6 +87,7 @@
87 87  * Support Modbus protocol
88 88  * Support Interrupt uplink (Since hardware version v1.2)
89 89  
97 +
90 90  == 1.4 Applications ==
91 91  
92 92  * Smart Buildings & Home Automation
... ... @@ -96,6 +96,7 @@
96 96  * Smart Cities
97 97  * Smart Factory
98 98  
107 +
99 99  == 1.5 Firmware Change log ==
100 100  
101 101  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -159,7 +159,7 @@
159 159  [[image:1653268227651-549.png||height="592" width="720"]]
160 160  
161 161  (((
162 -The LG308 is already set to connect to [[TTN V3 network >>path:eu1.cloud.thethings.network/]]. So what we need to now is only configure the TTN V3:
171 +The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:
163 163  )))
164 164  
165 165  (((
... ... @@ -211,7 +211,7 @@
211 211  
212 212  (((
213 213  (((
214 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#AT_COMMAND]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
223 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
215 215  )))
216 216  
217 217  (((
... ... @@ -283,6 +283,8 @@
283 283  )))
284 284  )))
285 285  
295 +
296 +
286 286  === 3.3.2 Configure sensors ===
287 287  
288 288  (((
... ... @@ -515,8 +515,8 @@
515 515  
516 516  === 3.5.3 Sensor related commands ===
517 517  
518 -==== ====
519 519  
530 +
520 520  ==== **RS485 Debug Command** ====
521 521  
522 522  This command is used to configure the RS485 devices; they won’t be used during sampling.
... ... @@ -731,7 +731,6 @@
731 731  **0x08 FF**, RS485-LN will immediately send an uplink.
732 732  
733 733  
734 -==== ====
735 735  
736 736  ==== **Clear RS485 Command** ====
737 737  
... ... @@ -849,6 +849,7 @@
849 849  |**RST**|(% style="width:1420px" %)Reboot RS485
850 850  |**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#upgrade_image]]
851 851  
862 +
852 852  == 3.8 LEDs ==
853 853  
854 854  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -856,6 +856,7 @@
856 856  |**PWR**|Always on if there is power
857 857  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
858 858  
870 +
859 859  = 4. Case Study =
860 860  
861 861  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1030,6 +1030,7 @@
1030 1030  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1031 1031  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1032 1032  
1045 +
1033 1033  = 9.Packing Info =
1034 1034  
1035 1035  
... ... @@ -1046,6 +1046,7 @@
1046 1046  * Package Size / pcs : 14.5 x 8 x 5 cm
1047 1047  * Weight / pcs : 170g
1048 1048  
1062 +
1049 1049  = 10. FCC Caution for RS485LN-US915 =
1050 1050  
1051 1051  Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0