... ... @@ -856,6 +856,8 @@
856 856  |**PWR**|Always on if there is power
857 857  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
858 858  
859 +
860 +
859 859  = 4. Case Study =
860 860  
861 861  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -922,7 +922,7 @@
922 922  
923 923  (% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off
924 924  
925 -(% style="background-color:#dcdcdc" %)**AT+DR=5**   (%%)Set Data Rate
927 +(% style="background-color:#dcdcdc" %)**AT+DR=5**  (%%)Set Data Rate
926 926  
927 927  (% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
928 928  
... ... @@ -944,7 +944,7 @@
944 944  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
945 945  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
946 946  
947 -[[image:1654162478620-421.png]]
949 +[[image:1654136435598-589.png]]
948 948  
949 949  
950 950  = 6. FAQ =
... ... @@ -951,15 +951,15 @@
951 951  
952 952  == 6.1 How to upgrade the image? ==
953 953  
954 -The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to:
956 +The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to:
955 955  
956 956  * Support new features
957 957  * For bug fix
958 958  * Change LoRaWAN bands.
959 959  
960 -Below shows the hardware connection for how to upload an image to RS485-LN:
962 +Below shows the hardware connection for how to upload an image to RS485-BL:
961 961  
962 -[[image:1654162535040-878.png]]
964 +[[image:1654136646995-976.png]]
963 963  
964 964  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
965 965  
... ... @@ -967,8 +967,6 @@
967 967  
968 968  **Step3: **Open flashloader; choose the correct COM port to update.
969 969  
970 -(% style="color:#037691" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
971 -
972 972  [[image:image-20220602102605-1.png]]
973 973  
974 974  
... ... @@ -978,23 +978,19 @@
978 978  [[image:image-20220602102715-3.png]]
979 979  
980 980  
981 +
981 981  == 6.2 How to change the LoRa Frequency Bands/Region? ==
982 982  
983 983  User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
984 984  
985 985  
987 +
986 986  == 6.3 How many RS485-Slave can RS485-BL connects? ==
987 987  
988 988  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
989 989  
990 990  
991 -== 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==
992 992  
993 -When user need to use with ChirpStack or TTI. Please set AT+RPL=4.
994 -
995 -Detail info check this link: [[Set Packet Receiving Response Level>>End Device AT Commands and Downlink Command||anchor="H7.23SetPacketReceivingResponseLevel"]]
996 -
997 -
998 998  = 7. Trouble Shooting =
999 999  
1000 1000  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0