From version < 51.2 >
edited by Xiaoling
on 2022/06/02 17:35
To version < 57.19 >
edited by Xiaoling
on 2022/06/06 09:12
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,5 @@
1 1  (% style="text-align:center" %)
2 -[[image:1653266934636-343.png||height="385" width="385"]]
2 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653266934636-343.png?width=385&height=385&rev=1.1||alt="1653266934636-343.png" height="385" width="385"]]
3 3  
4 4  
5 5  
... ... @@ -6,12 +6,70 @@
6 6  **RS485-LN – RS485 to LoRaWAN Converter User Manual**
7 7  
8 8  
9 +
10 +
9 9  **Table of Contents:**
10 10  
13 +* [[1.Introduction>>path:#H1.Introduction]]
14 +** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>path:#H1.1A0WhatisRS485-LNRS485toLoRaWANConverter]]
15 +** [[1.2 Specifications>>path:#H1.2A0Specifications]]
16 +** [[1.3 Features>>path:#H1.3Features]]
17 +** [[1.4 Applications>>path:#H1.4A0Applications]]
18 +** [[1.5 Firmware Change log>>path:#H1.5A0FirmwareChangelog]]
19 +** [[1.6 Hardware Change log>>path:#H1.6HardwareChangelog]]
20 +* [[2. Power ON Device>>path:#H2.PowerONDevice]]
21 +* [[3. Operation Mode>>path:#H3.A0OperationMode]]
22 +** [[3.1 How it works?>>path:#H3.1Howitworks3F]]
23 +** [[3.2 Example to join LoRaWAN network>>path:#H3.2ExampletojoinLoRaWANnetwork]]
24 +** [[3.3 Configure Commands to read data>>path:#H3.3ConfigureCommandstoreaddata]]
25 +*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>path:#H3.3.1onfigureUARTsettingsforRS485orTTLcommunication]]
26 +*** [[3.3.2 Configure sensors>>path:#H3.3.2Configuresensors]]
27 +*** [[3.3.3 Configure read commands for each sampling>>path:#H3.3.3Configurereadcommandsforeachsampling]]
28 +*** [[3.3.4 Compose the uplink payload>>path:#H3.3.4Composetheuplinkpayload]]
29 +*** [[3.3.5 Uplink on demand>>path:#H3.3.5Uplinkondemand]]
30 +*** [[3.3.6 Uplink on Interrupt>>path:#H3.3.6UplinkonInterrupt]]
31 +** [[3.4 Uplink Payload>>path:#H3.4UplinkPayload]]
32 +** [[3.5 Configure RS485-BL via AT or Downlink>>path:#H3.5ConfigureRS485-BLviaATorDownlink]]
33 +*** [[3.5.1 Common Commands>>path:#H3.5.1CommonCommands]]
34 +*** [[3.5.2 Sensor related commands>>path:#H3.5.2Sensorrelatedcommands]]
35 +*** [[3.5.3 Sensor related commands>>path:#H3.5.3A0Sensorrelatedcommands]]
36 +**** [[RS485 Debug Command>>path:#HRS485DebugCommand]]
37 +**** [[Set Payload version>>path:#HSetPayloadversion]]
38 +**** [[Set RS485 Sampling Commands>>path:#HSetRS485SamplingCommands]]
39 +**** [[Fast command to handle MODBUS device>>path:#HFastcommandtohandleMODBUSdevice]]
40 +**** [[RS485 command timeout>>path:#HRS485commandtimeout]]
41 +**** [[Uplink payload mode>>path:#HUplinkpayloadmode]]
42 +**** [[Manually trigger an Uplink>>path:#HManuallytriggeranUplink]]
43 +**** [[Clear RS485 Command>>path:#HClearRS485Command]]
44 +**** [[Set Serial Communication Parameters>>path:#HSetSerialCommunicationParameters]]
45 +** [[3.6 Listening mode for RS485 network>>path:#H3.6A0ListeningmodeforRS485network]]
46 +** [[3.7 Buttons>>path:#H3.7Buttons]]
47 +** [[3.8 LEDs>>path:#H3.8LEDs]]
48 +* [[4. Case Study>>path:#H4.CaseStudy]]
49 +* [[5. Use AT Command>>path:#H5.UseATCommand]]
50 +** [[5.1 Access AT Command>>path:#H5.1AccessATCommand]]
51 +** [[5.2 Common AT Command Sequence>>path:#H5.2CommonATCommandSequence]]
52 +*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>path:#H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829]]
53 +*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>path:#H5.5.2Single-channelABPmode28UsewithLG012FLG0229]]
54 +* [[6. FAQ>>path:#H6.FAQ]]
55 +** [[6.1 How to upgrade the image?>>path:#H6.1Howtoupgradetheimage3F]]
56 +** [[6.2 How to change the LoRa Frequency Bands/Region?>>path:#H6.2HowtochangetheLoRaFrequencyBands2FRegion3F]]
57 +** [[6.3 How many RS485-Slave can RS485-BL connects?>>path:#H6.3HowmanyRS485-SlavecanRS485-BLconnects3F]]
58 +** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>path:#H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F]]
59 +* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
60 +** [[7.1 Downlink doesn’t work, how to solve it?>>path:#H7.1Downlinkdoesn2019twork2Chowtosolveit3F]]
61 +** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>path:#H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F]]
62 +* [[8. Order Info>>path:#H8.OrderInfo]]
63 +* [[9.Packing Info>>path:#H9.PackingInfo]]
64 +* [[10. FCC Caution for RS485LN-US915>>path:#H10.FCCCautionforRS485LN-US915]]
65 +* [[11. Support>>path:#H11.Support]]
11 11  
12 12  
13 13  
14 14  
70 +
71 +
72 +
15 15  = 1.Introduction =
16 16  
17 17  == 1.1 What is RS485-LN RS485 to LoRaWAN Converter ==
... ... @@ -36,7 +36,7 @@
36 36  )))
37 37  )))
38 38  
39 -[[image:1653267211009-519.png||height="419" width="724"]]
97 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653267211009-519.png?width=724&height=419&rev=1.1||alt="1653267211009-519.png" height="419" width="724"]]
40 40  
41 41  
42 42  == 1.2 Specifications ==
... ... @@ -74,7 +74,7 @@
74 74  * Preamble detection.
75 75  * 127 dB Dynamic Range RSSI.
76 76  * Automatic RF Sense and CAD with ultra-fast AFC.
77 -* Packet engine up to 256 bytes with CRC.
135 +* Packet engine up to 256 bytes with CRC
78 78  
79 79  == 1.3 Features ==
80 80  
... ... @@ -125,7 +125,7 @@
125 125  Once there is power, the RS485-LN will be on.
126 126  )))
127 127  
128 -[[image:1653268091319-405.png]]
186 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268091319-405.png?rev=1.1||alt="1653268091319-405.png"]]
129 129  
130 130  
131 131  )))
... ... @@ -144,7 +144,7 @@
144 144  
145 145  Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
146 146  
147 -[[image:1653268155545-638.png||height="334" width="724"]]
205 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268155545-638.png?width=724&height=334&rev=1.1||alt="1653268155545-638.png" height="334" width="724"]]
148 148  
149 149  
150 150  (((
... ... @@ -156,10 +156,10 @@
156 156  485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively.
157 157  )))
158 158  
159 -[[image:1653268227651-549.png||height="592" width="720"]]
217 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268227651-549.png?width=720&height=592&rev=1.1||alt="1653268227651-549.png" height="592" width="720"]]
160 160  
161 161  (((
162 -The LG308 is already set to connect to [[TTN V3 network >>path:eu1.cloud.thethings.network/]]. So what we need to now is only configure the TTN V3:
220 +The LG308 is already set to connect to (% class="wikiinternallink" %)[[TTN V3 network >>url:https://www.thethingsnetwork.org/]](%%). So what we need to now is only configure the TTN V3:
163 163  )))
164 164  
165 165  (((
... ... @@ -171,7 +171,7 @@
171 171  )))
172 172  )))
173 173  
174 -[[image:1652953462722-299.png]]
232 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953462722-299.png?rev=1.1||alt="1652953462722-299.png"]]
175 175  
176 176  (((
177 177  (((
... ... @@ -183,21 +183,21 @@
183 183  )))
184 184  )))
185 185  
186 -[[image:image-20220519174512-1.png]]
244 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-1.png?rev=1.1||alt="image-20220519174512-1.png"]]
187 187  
188 -[[image:image-20220519174512-2.png||height="323" width="720"]]
246 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-2.png?width=720&height=323&rev=1.1||alt="image-20220519174512-2.png" height="323" width="720"]]
189 189  
190 -[[image:image-20220519174512-3.png||height="556" width="724"]]
248 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-3.png?width=724&height=556&rev=1.1||alt="image-20220519174512-3.png" height="556" width="724"]]
191 191  
192 -[[image:image-20220519174512-4.png]]
250 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-4.png?rev=1.1||alt="image-20220519174512-4.png"]]
193 193  
194 194  You can also choose to create the device manually.
195 195  
196 -[[image:1652953542269-423.png||height="710" width="723"]]
254 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953542269-423.png?width=723&height=710&rev=1.1||alt="1652953542269-423.png" height="710" width="723"]]
197 197  
198 198  Add APP KEY and DEV EUI
199 199  
200 -[[image:1652953553383-907.png||height="514" width="724"]]
258 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953553383-907.png?width=724&height=514&rev=1.1||alt="1652953553383-907.png" height="514" width="724"]]
201 201  
202 202  
203 203  (((
... ... @@ -204,7 +204,7 @@
204 204  **Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
205 205  )))
206 206  
207 -[[image:1652953568895-172.png||height="232" width="724"]]
265 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953568895-172.png?width=724&height=232&rev=1.1||alt="1652953568895-172.png" height="232" width="724"]]
208 208  
209 209  
210 210  == 3.3 Configure Commands to read data ==
... ... @@ -211,7 +211,7 @@
211 211  
212 212  (((
213 213  (((
214 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#AT_COMMAND]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
272 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
215 215  )))
216 216  
217 217  (((
... ... @@ -283,6 +283,7 @@
283 283  )))
284 284  )))
285 285  
344 +
286 286  === 3.3.2 Configure sensors ===
287 287  
288 288  (((
... ... @@ -301,6 +301,7 @@
301 301  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
302 302  )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
303 303  
363 +
304 304  === 3.3.3 Configure read commands for each sampling ===
305 305  
306 306  (((
... ... @@ -359,17 +359,17 @@
359 359  
360 360  * Grab bytes:
361 361  
362 -[[image:image-20220602153621-1.png]]
422 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-1.png?rev=1.1||alt="image-20220602153621-1.png"]]
363 363  
364 364  
365 365  * Grab a section.
366 366  
367 -[[image:image-20220602153621-2.png]]
427 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-2.png?rev=1.1||alt="image-20220602153621-2.png"]]
368 368  
369 369  
370 370  * Grab different sections.
371 371  
372 -[[image:image-20220602153621-3.png]]
432 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-3.png?rev=1.1||alt="image-20220602153621-3.png"]]
373 373  
374 374  
375 375  )))
... ... @@ -404,7 +404,7 @@
404 404  Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
405 405  )))
406 406  
407 -[[image:1653269759169-150.png||height="513" width="716"]]
467 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653269759169-150.png?width=716&height=513&rev=1.1||alt="1653269759169-150.png" height="513" width="716"]]
408 408  
409 409  
410 410  (% style="color:#037691" %)**Examples: AT+DATAUP=1**
... ... @@ -416,12 +416,13 @@
416 416  
417 417  (% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
418 418  
479 +
419 419  1. PAYVER: Defined by AT+PAYVER
420 420  1. PAYLOAD COUNT: Total how many uplinks of this sampling.
421 421  1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
422 422  1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes
423 423  
424 -[[image:image-20220602155039-4.png]]
485 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602155039-4.png?rev=1.1||alt="image-20220602155039-4.png"]]
425 425  
426 426  
427 427  So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA
... ... @@ -446,7 +446,7 @@
446 446  
447 447  Below are the uplink payloads:
448 448  
449 -[[image:1654157178836-407.png]]
510 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157178836-407.png?rev=1.1||alt="1654157178836-407.png"]]
450 450  
451 451  
452 452  === 3.3.5 Uplink on demand ===
... ... @@ -465,7 +465,7 @@
465 465  
466 466  RS485-LN support external Interrupt uplink since hardware v1.2 release.
467 467  
468 -[[image:1654157342174-798.png]]
529 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157342174-798.png?rev=1.1||alt="1654157342174-798.png"]]
469 469  
470 470  Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet.
471 471  
... ... @@ -495,13 +495,14 @@
495 495  
496 496  There are two kinds of Commands:
497 497  
498 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
559 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
499 499  
500 500  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
501 501  
563 +
502 502  === 3.5.1 Common Commands ===
503 503  
504 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
566 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
505 505  
506 506  
507 507  === 3.5.2 Sensor related commands ===
... ... @@ -508,7 +508,7 @@
508 508  
509 509  Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server.
510 510  
511 -[[image:image-20220602163333-5.png||height="263" width="1160"]]
573 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602163333-5.png?width=1160&height=263&rev=1.1||alt="image-20220602163333-5.png" height="263" width="1160"]]
512 512  
513 513  The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable)
514 514  
... ... @@ -515,8 +515,8 @@
515 515  
516 516  === 3.5.3 Sensor related commands ===
517 517  
518 -==== ====
519 519  
581 +
520 520  ==== **RS485 Debug Command** ====
521 521  
522 522  This command is used to configure the RS485 devices; they won’t be used during sampling.
... ... @@ -570,7 +570,7 @@
570 570  
571 571   **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
572 572  
573 - [[image:1654159460680-153.png]]
635 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654159460680-153.png?rev=1.1||alt="1654159460680-153.png"]]
574 574  
575 575  
576 576  
... ... @@ -597,7 +597,7 @@
597 597  
598 598  AT+COMMANDx or AT+DATACUTx
599 599  
600 -These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
662 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#H3.3.3Configurereadcommandsforeachsampling]].
601 601  
602 602  
603 603  * **AT Command:**
... ... @@ -654,9 +654,9 @@
654 654  * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
655 655  * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
656 656  
657 -[[image:image-20220602165351-6.png]]
719 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-6.png?rev=1.1||alt="image-20220602165351-6.png"]]
658 658  
659 -[[image:image-20220602165351-7.png]]
721 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-7.png?rev=1.1||alt="image-20220602165351-7.png"]]
660 660  
661 661  
662 662  
... ... @@ -694,7 +694,7 @@
694 694  
695 695  Define to use one uplink or multiple uplinks for the sampling.
696 696  
697 -The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
759 +The use of this command please see: [[Compose Uplink payload>>path:#H3.3.4Composetheuplinkpayload]]
698 698  
699 699  * **AT Command:**
700 700  
... ... @@ -723,7 +723,7 @@
723 723  
724 724  * **AT Command:**
725 725  
726 -No AT Command for this, user can press the [[ACT button>>path:#Button]] for 1 second for the same.
788 +No AT Command for this, user can press the (% class="wikiinternallink" %)[[ACT button>>path:#Button]](%%) for 1 second for the same.
727 727  
728 728  
729 729  * **Downlink Payload:**
... ... @@ -731,7 +731,6 @@
731 731  **0x08 FF**, RS485-LN will immediately send an uplink.
732 732  
733 733  
734 -==== ====
735 735  
736 736  ==== **Clear RS485 Command** ====
737 737  
... ... @@ -748,7 +748,7 @@
748 748  
749 749  The uplink screen shot is:
750 750  
751 -[[image:1654160691922-496.png]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]]
812 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654160691922-496.png?rev=1.1||alt="1654160691922-496.png"]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png||alt="file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png"]]
752 752  
753 753  
754 754  * **Downlink Payload:**
... ... @@ -805,7 +805,7 @@
805 805  
806 806  RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN.
807 807  
808 -[[image:image-20220602171200-8.png||height="567" width="1007"]]
869 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-8.png?width=1007&height=567&rev=1.1||alt="image-20220602171200-8.png" height="567" width="1007"]]
809 809  
810 810  To enable the listening mode, use can run the command AT+RXMODE.
811 811  
... ... @@ -834,7 +834,7 @@
834 834  
835 835  RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b  (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33
836 836  
837 -[[image:image-20220602171200-9.png]]
898 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-9.png?rev=1.1||alt="image-20220602171200-9.png"]]
838 838  
839 839  
840 840  (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
... ... @@ -847,7 +847,7 @@
847 847  |=**Button**|=(% style="width: 1420px;" %)**Feature**
848 848  |**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
849 849  |**RST**|(% style="width:1420px" %)Reboot RS485
850 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#upgrade_image]]
911 +|**PRO**|(% style="width:1420px" %)Use for upload image, see (% class="wikiinternallink" %)[[How to Update Image>>path:#upgrade_image]]
851 851  
852 852  == 3.8 LEDs ==
853 853  
... ... @@ -856,11 +856,9 @@
856 856  |**PWR**|Always on if there is power
857 857  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
858 858  
859 -
860 -
861 861  = 4. Case Study =
862 862  
863 -User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
922 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>path:/xwiki/bin/view/Main/Application%20Note%20%3A%20Communicate%20with%20Different%20Sensors%20-----%20RS485-LN%20%20RS485-BL/]]
864 864  
865 865  
866 866  = 5. Use AT Command =
... ... @@ -869,15 +869,15 @@
869 869  
870 870  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
871 871  
872 -[[image:1654162355560-817.png]]
931 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162355560-817.png?rev=1.1||alt="1654162355560-817.png"]]
873 873  
874 874  
875 875  In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
876 876  
877 -[[image:1654162368066-342.png]]
936 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162368066-342.png?rev=1.1||alt="1654162368066-342.png"]]
878 878  
879 879  
880 -More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]]
939 +More detail AT Command manual can be found at [[AT Command Manual>>path:#3.5ConfigureRS485-BLviaATorDownlink]]
881 881  
882 882  
883 883  == 5.2 Common AT Command Sequence ==
... ... @@ -924,7 +924,7 @@
924 924  
925 925  (% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off
926 926  
927 -(% style="background-color:#dcdcdc" %)**AT+DR=5**  (%%)Set Data Rate
986 +(% style="background-color:#dcdcdc" %)**AT+DR=5**   (%%)Set Data Rate
928 928  
929 929  (% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
930 930  
... ... @@ -946,7 +946,7 @@
946 946  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
947 947  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
948 948  
949 -[[image:1654162478620-421.png]]
1008 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162478620-421.png?rev=1.1||alt="1654162478620-421.png"]]
950 950  
951 951  
952 952  = 6. FAQ =
... ... @@ -961,7 +961,7 @@
961 961  
962 962  Below shows the hardware connection for how to upload an image to RS485-LN:
963 963  
964 -[[image:1654162535040-878.png]]
1023 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162535040-878.png?rev=1.1||alt="1654162535040-878.png"]]
965 965  
966 966  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
967 967  
... ... @@ -969,44 +969,55 @@
969 969  
970 970  **Step3: **Open flashloader; choose the correct COM port to update.
971 971  
972 -[[image:image-20220602102605-1.png]]
1031 +(% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
973 973  
974 974  
975 -[[image:image-20220602102637-2.png]]
1034 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175818-12.png?rev=1.1||alt="image-20220602175818-12.png"]]
976 976  
977 977  
978 -[[image:image-20220602102715-3.png]]
1037 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175848-13.png?rev=1.1||alt="image-20220602175848-13.png"]]
979 979  
980 980  
1040 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175912-14.png?rev=1.1||alt="image-20220602175912-14.png"]]
981 981  
982 -== 6.2 How to change the LoRa Frequency Bands/Region? ==
983 983  
984 -User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
1043 +**Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
985 985  
1045 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175638-10.png?rev=1.1||alt="image-20220602175638-10.png"]]
986 986  
987 987  
1048 +== 6.2 How to change the LoRa Frequency Bands/Region? ==
1049 +
1050 +User can follow the introduction for [[how to upgrade image>>path:#H6.1Howtoupgradetheimage3F]]. When download the images, choose the required image file for download.
1051 +
1052 +
988 988  == 6.3 How many RS485-Slave can RS485-BL connects? ==
989 989  
990 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1055 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#H3.3.3Configurereadcommandsforeachsampling]].
991 991  
992 992  
1058 +== 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==
993 993  
994 -= 7. Trouble Shooting =
1060 +When user need to use with ChirpStack or TTI. Please set AT+RPL=4.
995 995  
1062 +Detail info check this link: [[Set Packet Receiving Response Level>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.23SetPacketReceivingResponseLevel]]
996 996  
1064 +
1065 += 7. Trouble Shooting =
1066 +
997 997  == 7.1 Downlink doesn’t work, how to solve it? ==
998 998  
999 -Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]]
1069 +Please see this link for debug: [[LoRaWAN Communication Debug>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/]]
1000 1000  
1001 1001  
1002 1002  == 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? ==
1003 1003  
1004 -It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1074 +It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]]
1005 1005  
1006 1006  
1007 1007  = 8. Order Info =
1008 1008  
1009 -(% style="color:blue" %)**Part Number: RS485-BL-XXX**
1079 +(% style="color:blue" %)**Part Number: RS485-LN-XXX**
1010 1010  
1011 1011  (% style="color:blue" %)**XXX:**
1012 1012  
... ... @@ -1021,5 +1021,48 @@
1021 1021  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1022 1022  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1023 1023  
1024 -(% class="wikigeneratedid" %)
1025 -
1094 += 9.Packing Info =
1095 +
1096 +
1097 +**Package Includes**:
1098 +
1099 +* RS485-LN x 1
1100 +* Stick Antenna for LoRa RF part x 1
1101 +* Program cable x 1
1102 +
1103 +**Dimension and weight**:
1104 +
1105 +* Device Size: 13.5 x 7 x 3 cm
1106 +* Device Weight: 105g
1107 +* Package Size / pcs : 14.5 x 8 x 5 cm
1108 +* Weight / pcs : 170g
1109 +
1110 += 10. FCC Caution for RS485LN-US915 =
1111 +
1112 +Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
1113 +
1114 +This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
1115 +
1116 +
1117 +**IMPORTANT NOTE:**
1118 +
1119 +**Note: **This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1120 +
1121 +—Reorient or relocate the receiving antenna.
1122 +
1123 +—Increase the separation between the equipment and receiver.
1124 +
1125 +—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
1126 +
1127 +—Consult the dealer or an experienced radio/TV technician for help.
1128 +
1129 +
1130 +**FCC Radiation Exposure Statement:**
1131 +
1132 +This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.
1133 +
1134 +
1135 += 11. Support =
1136 +
1137 +* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1138 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
image-20220602175638-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +85.5 KB
Content
image-20220602175743-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +85.5 KB
Content
image-20220602175818-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +102.5 KB
Content
image-20220602175848-13.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +250.9 KB
Content
image-20220602175912-14.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +176.1 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0