Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Karry Zhuang on 2025/03/06 16:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 6 removed)
Details
- Page properties
-
- Content
-
... ... @@ -585,6 +585,7 @@ 585 585 **AT+PAYVER: Set PAYVER field = 1** 586 586 ))) 587 587 588 + 588 588 * **Downlink Payload:** 589 589 590 590 **0xAE 01** ~-~-> Set PAYVER field = 0x01 ... ... @@ -595,9 +595,9 @@ 595 595 596 596 ==== **Set RS485 Sampling Commands** ==== 597 597 598 -AT+COMMANDx orAT+DATACUTx599 +AT+COMMANDx, AT+DATACUTx and AT+SEARCHx 599 599 600 -These three commands are used to configure how the RS485-L Npolling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].601 +These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 601 601 602 602 603 603 * **AT Command:** ... ... @@ -612,7 +612,12 @@ 612 612 **AT+DATACUTx: Configure how to handle return from RS485 devices.** 613 613 ))) 614 614 616 +(% class="box infomessage" %) 617 +((( 618 +**AT+SEARCHx: Configure search command** 619 +))) 615 615 621 + 616 616 * **Downlink Payload:** 617 617 618 618 **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. ... ... @@ -627,7 +627,7 @@ 627 627 * NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 628 628 * LL: The length of AT+COMMAND or AT+DATACUT command 629 629 * XX XX XX XX: AT+COMMAND or AT+DATACUT command 630 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-L Nwill execute an uplink after got this command.636 +* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 631 631 632 632 **Example:** 633 633 ... ... @@ -638,7 +638,17 @@ 638 638 (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10** 639 639 640 640 647 +**0xAB** downlink command can be used for set AT+SEARCHx 641 641 649 +**Example:** **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So 650 + 651 +* AB aa 01 03 xx xx xx same as AT+SEARCHaa=1,xx xx xx 652 +* AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands 653 + 654 +**AB aa 02 03 xx xx xx 02 yy yy** same as **AT+SEARCHaa=2,xx xx xx+yy yy** 655 + 656 + 657 + 642 642 ==== **Fast command to handle MODBUS device** ==== 643 643 644 644 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. ... ... @@ -645,32 +645,45 @@ 645 645 646 646 This command is valid since v1.3 firmware version 647 647 648 -AT+MBFUN can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 649 649 665 +**AT+MBFUN has only two value:** 650 650 667 +* **AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return 668 + 669 +AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 670 + 671 +* **AT+MBFUN=0**: Disable Modbus fast reading. 672 + 651 651 **Example:** 652 652 653 -* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.675 +* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). 654 654 * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 655 655 * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 656 656 657 -[[image: image-20220602165351-6.png]]679 +[[image:1654133913295-597.png]] 658 658 659 -[[image:image-20220602165351-7.png]] 660 660 682 +[[image:1654133954153-643.png]] 661 661 662 662 685 +* **Downlink Commands:** 686 + 687 +**A9 aa** ~-~-> Same as AT+MBFUN=aa 688 + 689 + 690 + 663 663 ==== **RS485 command timeout** ==== 664 664 665 -Some Modbus device has slow action to send replies. This command is used to configure the RS485-L Nto use longer time to wait for their action.693 +Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 666 666 667 -Default value: 0, range: 0 ~~ 65 seconds695 +Default value: 0, range: 0 ~~ 5 seconds 668 668 697 + 669 669 * **AT Command:** 670 670 671 671 (% class="box infomessage" %) 672 672 ((( 673 -**AT+CMDDLaa=hex(bb cc)* 1000**702 +**AT+CMDDLaa=hex(bb cc)** 674 674 ))) 675 675 676 676 **Example:** ... ... @@ -680,13 +680,13 @@ 680 680 681 681 * **Downlink Payload:** 682 682 683 - **0x AA aa bb cc**712 +0x AA aa bb cc 684 684 685 -Same as: AT+CMDDLaa=hex(bb cc) *1000714 +Same as: AT+CMDDLaa=hex(bb cc) 686 686 687 687 **Example:** 688 688 689 - 0xAA 01 0 001~-~-> Same as **AT+CMDDL1=1000 ms**718 + **0xAA 01 03 E8** ~-~-> Same as **AT+CMDDL1=1000 ms** 690 690 691 691 692 692 ... ... @@ -721,34 +721,27 @@ 721 721 722 722 Ask device to send an uplink immediately. 723 723 724 -* **AT Command:** 725 - 726 -No AT Command for this, user can press the [[ACT button>>path:#Button]] for 1 second for the same. 727 - 728 - 729 729 * **Downlink Payload:** 730 730 731 -**0x08 FF**, RS485-L Nwill immediately send an uplink.755 +**0x08 FF**, RS485-BL will immediately send an uplink. 732 732 733 733 734 -==== ==== 735 735 736 736 ==== **Clear RS485 Command** ==== 737 737 738 738 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 739 739 763 + 740 740 * **AT Command:** 741 741 742 -**AT+CMDEAR=mm,nn** 766 +(% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 743 743 744 -Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 745 - 746 746 Example screen shot after clear all RS485 commands. 747 747 748 748 749 749 The uplink screen shot is: 750 750 751 -[[image:16541 60691922-496.png]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]]773 +[[image:1654134704555-320.png]] 752 752 753 753 754 754 * **Downlink Payload:** ... ... @@ -799,227 +799,22 @@ 799 799 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 800 800 801 801 802 -== 3.6 Listening mode for RS485 network == 803 803 804 - Thisfeaturesupportsincefirmware v1.4825 +==== **Control output power duration** ==== 805 805 806 - RS485-LNsupportslistening mode, itcanlistentheRS485 network packets and send themvia LoRaWANuplink.Belowis thestructure.The blue arrowshows theRS485 networkpacketsto RS485-LN.827 +User can set the output power duration before each sampling. 807 807 808 - [[image:image-20220602171200-8.png||height="567" width="1007"]]829 +* **AT Command:** 809 809 810 - To enablethe listening mode, use can run the command AT+RXMODE.831 +**Example:** 811 811 833 +**AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 812 812 813 -(% border="1" style="background-color:#ffffcc; width:500px" %) 814 -|=(% style="width: 161px;" %)**Command example:**|=(% style="width: 337px;" %)**Function** 815 -|(% style="width:161px" %)AT+RXMODE=1,10 |(% style="width:337px" %)Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 816 -|(% style="width:161px" %)AT+RXMODE=2,500|(% style="width:337px" %)Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 817 -|(% style="width:161px" %)AT+RXMODE=0,0|(% style="width:337px" %)Disable listening mode. This is the default settings. 818 -|(% style="width:161px" %) |(% style="width:337px" %)A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 ~| cc) 835 +**AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 819 819 820 -**Downlink Command:** 821 821 822 -* *0xA6aa bb cc**same asAT+RXMODE=aa,(bb<<8| cc)838 +* **LoRaWAN Downlink Command:** 823 823 840 +**07 01 aa bb** Same as AT+5VT=(aa bb) 824 824 825 -**Example**: 826 - 827 -The RS485-LN is set to AT+RXMODE=2,1000 828 - 829 -There is a two Modbus commands in the RS485 network as below: 830 - 831 -The Modbus master send a command: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b 832 - 833 -And Modbus slave reply with: (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 834 - 835 -RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 836 - 837 -[[image:image-20220602171200-9.png]] 838 - 839 - 840 -(% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 841 - 842 - 843 -== 3.7 Buttons == 844 - 845 - 846 -(% border="1" style="background-color:#f7faff; width:500px" %) 847 -|=**Button**|=(% style="width: 1420px;" %)**Feature** 848 -|**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 849 -|**RST**|(% style="width:1420px" %)Reboot RS485 850 -|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>path:#upgrade_image]] 851 - 852 -== 3.8 LEDs == 853 - 854 -(% border="1" style="background-color:#f7faff; width:500px" %) 855 -|=**LEDs**|=**Feature** 856 -|**PWR**|Always on if there is power 857 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 858 - 859 - 860 - 861 -= 4. Case Study = 862 - 863 -User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] 864 - 865 - 866 -= 5. Use AT Command = 867 - 868 -== 5.1 Access AT Command == 869 - 870 -RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 871 - 872 -[[image:1654135840598-282.png]] 873 - 874 - 875 -In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 876 - 877 -[[image:1654136105500-922.png]] 878 - 879 - 880 -More detail AT Command manual can be found at [[AT Command Manual>>||anchor="3.5ConfigureRS485-BLviaATorDownlink"]] 881 - 882 - 883 -== 5.2 Common AT Command Sequence == 884 - 885 -=== 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 886 - 887 -If device has not joined network yet: 888 - 889 -(% class="box infomessage" %) 890 -((( 891 -**AT+FDR** 892 -))) 893 - 894 -(% class="box infomessage" %) 895 -((( 896 -**AT+NJM=0** 897 -))) 898 - 899 -(% class="box infomessage" %) 900 -((( 901 -**ATZ** 902 -))) 903 - 904 - 905 -If device already joined network: 906 - 907 -(% class="box infomessage" %) 908 -((( 909 -**AT+NJM=0** 910 -))) 911 - 912 -(% class="box infomessage" %) 913 -((( 914 -**ATZ** 915 -))) 916 - 917 - 918 -=== 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 919 - 920 - 921 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 922 - 923 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 924 - 925 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 926 - 927 -(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 928 - 929 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 930 - 931 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 932 - 933 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 934 - 935 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 936 - 937 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 938 - 939 -(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 940 - 941 - 942 -(% style="color:red" %)**Note:** 943 - 944 -(% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 945 -2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 946 -3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 947 -4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 948 - 949 -[[image:1654136435598-589.png]] 950 - 951 - 952 -= 6. FAQ = 953 - 954 -== 6.1 How to upgrade the image? == 955 - 956 -The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to: 957 - 958 -* Support new features 959 -* For bug fix 960 -* Change LoRaWAN bands. 961 - 962 -Below shows the hardware connection for how to upload an image to RS485-BL: 963 - 964 -[[image:1654136646995-976.png]] 965 - 966 -**Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 967 - 968 -**Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 969 - 970 -**Step3: **Open flashloader; choose the correct COM port to update. 971 - 972 -[[image:image-20220602102605-1.png]] 973 - 974 - 975 -[[image:image-20220602102637-2.png]] 976 - 977 - 978 -[[image:image-20220602102715-3.png]] 979 - 980 - 981 - 982 -== 6.2 How to change the LoRa Frequency Bands/Region? == 983 - 984 -User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download. 985 - 986 - 987 - 988 -== 6.3 How many RS485-Slave can RS485-BL connects? == 989 - 990 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 991 - 992 - 993 - 994 -= 7. Trouble Shooting = 995 - 996 - 997 -== 7.1 Downlink doesn’t work, how to solve it? == 998 - 999 -Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]] 1000 - 1001 - 1002 -== 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? == 1003 - 1004 -It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 1005 - 1006 - 1007 -= 8. Order Info = 1008 - 1009 -(% style="color:blue" %)**Part Number: RS485-BL-XXX** 1010 - 1011 -(% style="color:blue" %)**XXX:** 1012 - 1013 -* (% style="color:blue" %)**EU433**(%%): frequency bands EU433 1014 -* (% style="color:blue" %)**EU868**(%%): frequency bands EU868 1015 -* (% style="color:blue" %)**KR920**(%%): frequency bands KR920 1016 -* (% style="color:blue" %)**CN470**(%%): frequency bands CN470 1017 -* (% style="color:blue" %)**AS923**(%%): frequency bands AS923 1018 -* (% style="color:blue" %)**AU915**(%%): frequency bands AU915 1019 -* (% style="color:blue" %)**US915**(%%): frequency bands US915 1020 -* (% style="color:blue" %)**IN865**(%%): frequency bands IN865 1021 -* (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1022 -* (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1023 - 1024 -(% class="wikigeneratedid" %) 1025 - 842 +**07 02 aa bb** Same as AT+3V3T=(aa bb)
- 1654160691922-496.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -109.3 KB - Content
- 1654162355560-817.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -670.0 KB - Content
- 1654162368066-342.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -192.9 KB - Content
- image-20220602165351-7.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.3 KB - Content
- image-20220602171200-8.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -276.1 KB - Content
- image-20220602171200-9.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -10.0 KB - Content