... ... @@ -662,15 +662,16 @@
662 662  
663 663  ==== **RS485 command timeout** ====
664 664  
665 -Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
665 +Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action.
666 666  
667 -Default value: 0, range:  0 ~~ 65 seconds
667 +Default value: 0, range:  0 ~~ 5 seconds
668 668  
669 +
669 669  * **AT Command:**
670 670  
671 671  (% class="box infomessage" %)
672 672  (((
673 -**AT+CMDDLaa=hex(bb cc)*1000**
674 +**AT+CMDDLaa=hex(bb cc)**
674 674  )))
675 675  
676 676  **Example:**
... ... @@ -680,13 +680,13 @@
680 680  
681 681  * **Downlink Payload:**
682 682  
683 -**0x AA aa bb cc**
684 +0x AA aa bb cc
684 684  
685 -Same as: AT+CMDDLaa=hex(bb cc)*1000
686 +Same as: AT+CMDDLaa=hex(bb cc)
686 686  
687 687   **Example:**
688 688  
689 - 0xAA 01 00 01  ~-~-> Same as **AT+CMDDL1=1000 ms**
690 + **0xAA 01 03 E8**  ~-~-> Same as **AT+CMDDL1=1000 ms**
690 690  
691 691  
692 692  
... ... @@ -721,34 +721,27 @@
721 721  
722 722  Ask device to send an uplink immediately.
723 723  
724 -* **AT Command:**
725 -
726 -No AT Command for this, user can press the [[ACT button>>path:#Button]] for 1 second for the same.
727 -
728 -
729 729  * **Downlink Payload:**
730 730  
731 -**0x08 FF**, RS485-LN will immediately send an uplink.
727 +**0x08 FF**, RS485-BL will immediately send an uplink.
732 732  
733 733  
734 -==== ====
735 735  
736 736  ==== **Clear RS485 Command** ====
737 737  
738 738  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
739 739  
735 +
740 740  * **AT Command:**
741 741  
742 -**AT+CMDEAR=mm,nn**   mm: start position of erase ,nn: stop position of erase
738 +(% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
743 743  
744 -Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
740 +Example screen shot after clear all RS485 commands. 
745 745  
746 -Example screen shot after clear all RS485 commands.
747 747  
748 -
749 749  The uplink screen shot is:
750 750  
751 -[[image:1654160691922-496.png]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]]
745 +[[image:1654134704555-320.png]]
752 752  
753 753  
754 754  * **Downlink Payload:**
... ... @@ -800,4 +800,21 @@
800 800  
801 801  
802 802  
803 -==== ====
797 +==== **Control output power duration** ====
798 +
799 +User can set the output power duration before each sampling.
800 +
801 +* **AT Command:**
802 +
803 +**Example:**
804 +
805 +**AT+3V3T=1000**  ~/~/ 3V3 output power will open 1s before each sampling.
806 +
807 +**AT+5VT=1000**  ~/~/ +5V output power will open 1s before each sampling.
808 +
809 +
810 +* **LoRaWAN Downlink Command:**
811 +
812 +**07 01 aa bb**  Same as AT+5VT=(aa bb)
813 +
814 +**07 02 aa bb**  Same as AT+3V3T=(aa bb)
1654160691922-496.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -109.3 KB
Content
image-20220602171200-8.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -276.1 KB
Content