... ... @@ -662,15 +662,16 @@
662 662  
663 663  ==== **RS485 command timeout** ====
664 664  
665 -Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
665 +Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action.
666 666  
667 -Default value: 0, range:  0 ~~ 65 seconds
667 +Default value: 0, range:  0 ~~ 5 seconds
668 668  
669 +
669 669  * **AT Command:**
670 670  
671 671  (% class="box infomessage" %)
672 672  (((
673 -**AT+CMDDLaa=hex(bb cc)*1000**
674 +**AT+CMDDLaa=hex(bb cc)**
674 674  )))
675 675  
676 676  **Example:**
... ... @@ -680,13 +680,13 @@
680 680  
681 681  * **Downlink Payload:**
682 682  
683 -**0x AA aa bb cc**
684 +0x AA aa bb cc
684 684  
685 -Same as: AT+CMDDLaa=hex(bb cc)*1000
686 +Same as: AT+CMDDLaa=hex(bb cc)
686 686  
687 687   **Example:**
688 688  
689 - 0xAA 01 00 01  ~-~-> Same as **AT+CMDDL1=1000 ms**
690 + **0xAA 01 03 E8**  ~-~-> Same as **AT+CMDDL1=1000 ms**
690 690  
691 691  
692 692  
... ... @@ -721,47 +721,17 @@
721 721  
722 722  Ask device to send an uplink immediately.
723 723  
724 -* **AT Command:**
725 -
726 -No AT Command for this, user can press the [[ACT button>>path:#Button]] for 1 second for the same.
727 -
728 -
729 729  * **Downlink Payload:**
730 730  
731 -**0x08 FF**, RS485-LN will immediately send an uplink.
727 +**0x08 FF**, RS485-BL will immediately send an uplink.
732 732  
733 733  
734 -==== ====
735 735  
736 736  ==== **Clear RS485 Command** ====
737 737  
738 738  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
739 739  
740 -* **AT Command:**
741 741  
742 -**AT+CMDEAR=mm,nn**   mm: start position of erase ,nn: stop position of erase
743 -
744 -Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
745 -
746 -Example screen shot after clear all RS485 commands.
747 -
748 -
749 -The uplink screen shot is:
750 -
751 -[[image:1654160691922-496.png]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]]
752 -
753 -
754 -* **Downlink Payload:**
755 -
756 -**0x09 aa bb** same as AT+CMDEAR=aa,bb
757 -
758 -
759 -
760 -==== **Clear RS485 Command** ====
761 -
762 -The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
763 -
764 -
765 765  * **AT Command:**
766 766  
767 767  (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
1654160691922-496.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -109.3 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0