Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Karry Zhuang on 2025/03/06 16:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -662,16 +662,15 @@ 662 662 663 663 ==== **RS485 command timeout** ==== 664 664 665 -Some Modbus device has slow action to send replies. This command is used to configure the RS485- BL to use longer time to wait for their action.665 +Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. 666 666 667 -Default value: 0, range: 0 ~~ 5 seconds 667 +Default value: 0, range: 0 ~~ 65 seconds 668 668 669 - 670 670 * **AT Command:** 671 671 672 672 (% class="box infomessage" %) 673 673 ((( 674 -**AT+CMDDLaa=hex(bb cc)** 673 +**AT+CMDDLaa=hex(bb cc)*1000** 675 675 ))) 676 676 677 677 **Example:** ... ... @@ -681,13 +681,13 @@ 681 681 682 682 * **Downlink Payload:** 683 683 684 -0x AA aa bb cc 683 +**0x AA aa bb cc** 685 685 686 -Same as: AT+CMDDLaa=hex(bb cc) 685 +Same as: AT+CMDDLaa=hex(bb cc)*1000 687 687 688 688 **Example:** 689 689 690 - **0xAA 01 03E8**~-~-> Same as **AT+CMDDL1=1000 ms**689 + 0xAA 01 00 01 ~-~-> Same as **AT+CMDDL1=1000 ms** 691 691 692 692 693 693 ... ... @@ -722,27 +722,34 @@ 722 722 723 723 Ask device to send an uplink immediately. 724 724 724 +* **AT Command:** 725 + 726 +No AT Command for this, user can press the [[ACT button>>path:#Button]] for 1 second for the same. 727 + 728 + 725 725 * **Downlink Payload:** 726 726 727 -**0x08 FF**, RS485- BL will immediately send an uplink.731 +**0x08 FF**, RS485-LN will immediately send an uplink. 728 728 729 729 734 +==== ==== 730 730 731 731 ==== **Clear RS485 Command** ==== 732 732 733 733 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 734 734 735 - 736 736 * **AT Command:** 737 737 738 - (% style="color:#037691" %)**AT+CMDEAR=mm,nn**(%%)mm: start position of erase ,nn: stop position of eraseEtc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10742 +**AT+CMDEAR=mm,nn** mm: start position of erase ,nn: stop position of erase 739 739 744 +Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 745 + 740 740 Example screen shot after clear all RS485 commands. 741 741 742 742 743 743 The uplink screen shot is: 744 744 745 -[[image:16541 34704555-320.png]]751 +[[image:1654160691922-496.png]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]] 746 746 747 747 748 748 * **Downlink Payload:** ... ... @@ -793,22 +793,45 @@ 793 793 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 794 794 795 795 802 +== 3.6 Listening mode for RS485 network == 796 796 797 - ====**Controloutputpowerduration**====804 +This feature support since firmware v1.4 798 798 799 - User can set theoutputpowerdurationbefore eachsampling.806 +RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN. 800 800 801 - * **AT Command:**808 +[[image:image-20220602171200-8.png||height="567" width="1007"]] 802 802 803 - **Example:**810 +To enable the listening mode, use can run the command AT+RXMODE. 804 804 805 -**AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 806 806 807 -**AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 813 +(% border="1" style="background-color:#ffffcc; width:500px" %) 814 +|=(% style="width: 161px;" %)**Command example:**|=(% style="width: 337px;" %)**Function** 815 +|(% style="width:161px" %)AT+RXMODE=1,10 |(% style="width:337px" %)Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 816 +|(% style="width:161px" %)AT+RXMODE=2,500|(% style="width:337px" %)Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 817 +|(% style="width:161px" %)AT+RXMODE=0,0|(% style="width:337px" %)Disable listening mode. This is the default settings. 818 +|(% style="width:161px" %) |(% style="width:337px" %)A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 ~| cc) 808 808 820 +**Downlink Command:** 809 809 810 -* ** LoRaWANDownlinkCommand:**822 +**0xA6 aa bb cc ** same as AT+RXMODE=aa,(bb<<8 | cc) 811 811 812 -**07 01 aa bb** Same as AT+5VT=(aa bb) 813 813 814 -**07 02 aa bb** Same as AT+3V3T=(aa bb) 825 +**Example**: 826 + 827 +The RS485-LN is set to AT+RXMODE=2,1000 828 + 829 +There is a two Modbus commands in the RS485 network as below: 830 + 831 +The Modbus master send a command: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b 832 + 833 +And Modbus slave reply with: (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 834 + 835 +RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 836 + 837 +[[image:image-20220602171200-9.png]] 838 + 839 + 840 +Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 841 + 842 + 843 +==== ====
- 1654160691922-496.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +109.3 KB - Content
- image-20220602171200-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +276.1 KB - Content
- image-20220602171200-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.0 KB - Content